NDIR CO2 Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.
- Author : MikroE Team
- Date : Dec 2019.
- Type : I2C type
This application measures absolute CO2 concetration.
- MikroSDK.Board
- MikroSDK.Log
- Click.NDIRCO2
ndirco2_cfg_setupConfig Object Initialization function.
void ndirco2_cfg_setup ( ndirco2_cfg_t *cfg );ndirco2_initInitialization function.
err_t ndirco2_init ( ndirco2_t *ctx, ndirco2_cfg_t *cfg );ndirco2_read_co2CO2 Concentration Read function.
void ndirco2_read_co2 ( ndirco2_t *ctx, uint8_t set_check_mode, uint16_t *output_data );ndirco2_check_average_completeAverage Complete Check function.
uint8_t ndirco2_check_average_complete ( ndirco2_t *ctx );ndirco2_set_modeMode Set function.
void ndirco2_set_mode ( ndirco2_t *ctx, uint8_t select_mode );Initializes I2C driver and performs driver reset and determines number of averaging measurements.
void application_init ( void )
{
log_cfg_t log_cfg;
ndirco2_cfg_t cfg;
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, "---- Application Init ----" );
// Click initialization.
ndirco2_cfg_setup( &cfg );
NDIRCO2_MAP_MIKROBUS( cfg, MIKROBUS_POSITION_NDIRCO2 );
ndirco2_init( &ndirco2, &cfg );
Delay_ms ( 300 );
ndirco2_reset( &ndirco2 );
ndirco2_write_register( &ndirco2, NDIRCO2_AVERAGING_COUNT_REG, 0x03 );
ndirco2_set_mode( &ndirco2, NDIRCO2_CONTINUOUS_OP_MODE );
log_printf( &logger, "NDIR CO2 is initialized \r\n" );
Delay_ms ( 200 );
}Reads CO2 concentration data in ppm unit after each completed measurement. One measurement is finished after 300 ms, and period between two measurements is 2 seconds. Results of measurements logs on USBUART.
void application_task ( )
{
uint16_t co2_data;
ndirco2_read_co2( &ndirco2, NDIRCO2_CHECK_EACH_MEASURE, &co2_data );
log_printf( &logger, "CO2 concentration is: %d ppm \r\n", co2_data );
}This Click board can be interfaced and monitored in two ways:
- Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
- UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.
The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.