This repository was archived by the owner on Jul 22, 2024. It is now read-only.
-
Notifications
You must be signed in to change notification settings - Fork 2
/
Copy patharosg.worker.js
219 lines (186 loc) · 9 KB
/
arosg.worker.js
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
// Copyright 2015 The Emscripten Authors. All rights reserved.
// Emscripten is available under two separate licenses, the MIT license and the
// University of Illinois/NCSA Open Source License. Both these licenses can be
// found in the LICENSE file.
// Pthread Web Worker startup routine:
// This is the entry point file that is loaded first by each Web Worker
// that executes pthreads on the Emscripten application.
// Thread-local:
var threadInfoStruct = 0; // Info area for this thread in Emscripten HEAP (shared). If zero, this worker is not currently hosting an executing pthread.
var selfThreadId = 0; // The ID of this thread. 0 if not hosting a pthread.
var parentThreadId = 0; // The ID of the parent pthread that launched this thread.
var noExitRuntime;
// performance.now() is specced to return a wallclock time in msecs since that Web Worker/main thread launched. However for pthreads this can cause
// subtle problems in emscripten_get_now() as this essentially would measure time from pthread_create(), meaning that the clocks between each threads
// would be wildly out of sync. Therefore sync all pthreads to the clock on the main browser thread, so that different threads see a somewhat
// coherent clock across each of them (+/- 0.1msecs in testing)
var __performance_now_clock_drift = 0;
// Cannot use console.log or console.error in a web worker, since that would risk a browser deadlock! https://bugzilla.mozilla.org/show_bug.cgi?id=1049091
// Therefore implement custom logging facility for threads running in a worker, which queue the messages to main thread to print.
var Module = {};
// These modes need to assign to these variables because of how scoping works in them.
var PThread;
var HEAPU32;
function assert(condition, text) {
if (!condition) abort('Assertion failed: ' + text);
}
function threadPrintErr() {
var text = Array.prototype.slice.call(arguments).join(' ');
console.error(text);
console.error(new Error().stack);
}
function threadAlert() {
var text = Array.prototype.slice.call(arguments).join(' ');
postMessage({cmd: 'alert', text: text, threadId: selfThreadId});
}
var err = threadPrintErr;
this.alert = threadAlert;
// When using postMessage to send an object, it is processed by the structured clone algorithm.
// The prototype, and hence methods, on that object is then lost. This function adds back the lost prototype.
// This does not work with nested objects that has prototypes, but it suffices for WasmSourceMap and WasmOffsetConverter.
function resetPrototype(constructor, attrs) {
var object = Object.create(constructor.prototype);
for (var key in attrs) {
if (attrs.hasOwnProperty(key)) {
object[key] = attrs[key];
}
}
return object;
}
Module['instantiateWasm'] = function(info, receiveInstance) {
// Instantiate from the module posted from the main thread.
// We can just use sync instantiation in the worker.
var instance = new WebAssembly.Instance(Module['wasmModule'], info);
// We don't need the module anymore; new threads will be spawned from the main thread.
Module['wasmModule'] = null;
receiveInstance(instance); // The second 'module' parameter is intentionally null here, we don't need to keep a ref to the Module object from here.
return instance.exports;
};
this.onmessage = function(e) {
try {
if (e.data.cmd === 'load') { // Preload command that is called once per worker to parse and load the Emscripten code.
// Initialize the global "process"-wide fields:
Module['DYNAMIC_BASE'] = e.data.DYNAMIC_BASE;
Module['DYNAMICTOP_PTR'] = e.data.DYNAMICTOP_PTR;
// Module and memory were sent from main thread
Module['wasmModule'] = e.data.wasmModule;
Module['wasmMemory'] = e.data.wasmMemory;
Module['buffer'] = Module['wasmMemory'].buffer;
Module['ENVIRONMENT_IS_PTHREAD'] = true;
import(e.data.urlOrBlob).then(function(Module) {
Module = Module.default(Module);
PThread = Module['PThread'];
HEAPU32 = Module['HEAPU32'];
postMessage({ cmd: 'loaded' });
});
} else if (e.data.cmd === 'objectTransfer') {
PThread.receiveObjectTransfer(e.data);
} else if (e.data.cmd === 'run') { // This worker was idle, and now should start executing its pthread entry point.
__performance_now_clock_drift = performance.now() - e.data.time; // Sync up to the clock of the main thread.
threadInfoStruct = e.data.threadInfoStruct;
Module['__register_pthread_ptr'](threadInfoStruct, /*isMainBrowserThread=*/0, /*isMainRuntimeThread=*/0); // Pass the thread address inside the asm.js scope to store it for fast access that avoids the need for a FFI out.
selfThreadId = e.data.selfThreadId;
parentThreadId = e.data.parentThreadId;
// Establish the stack frame for this thread in global scope
// The stack grows downwards
var max = e.data.stackBase;
var top = e.data.stackBase + e.data.stackSize;
assert(threadInfoStruct);
assert(selfThreadId);
assert(parentThreadId);
assert(top != 0);
assert(e.data.stackSize > 0);
assert(top > max);
// Also call inside JS module to set up the stack frame for this pthread in JS module scope
Module['establishStackSpaceInJsModule'](top, max);
Module['_emscripten_tls_init']();
PThread.receiveObjectTransfer(e.data);
PThread.setThreadStatus(Module['_pthread_self'](), 1/*EM_THREAD_STATUS_RUNNING*/);
try {
// pthread entry points are always of signature 'void *ThreadMain(void *arg)'
// Native codebases sometimes spawn threads with other thread entry point signatures,
// such as void ThreadMain(void *arg), void *ThreadMain(), or void ThreadMain().
// That is not acceptable per C/C++ specification, but x86 compiler ABI extensions
// enable that to work. If you find the following line to crash, either change the signature
// to "proper" void *ThreadMain(void *arg) form, or try linking with the Emscripten linker
// flag -s EMULATE_FUNCTION_POINTER_CASTS=1 to add in emulation for this x86 ABI extension.
var result = Module['dynCall_ii'](e.data.start_routine, e.data.arg);
Module['checkStackCookie']();
} catch(e) {
if (e === 'Canceled!') {
PThread.threadCancel();
return;
} else if (e == 'unwind') {
return;
} else {
Atomics.store(HEAPU32, (threadInfoStruct + 4 /*C_STRUCTS.pthread.threadExitCode*/ ) >> 2, (e instanceof Module['ExitStatus']) ? e.status : -2 /*A custom entry specific to Emscripten denoting that the thread crashed.*/);
Atomics.store(HEAPU32, (threadInfoStruct + 0 /*C_STRUCTS.pthread.threadStatus*/ ) >> 2, 1); // Mark the thread as no longer running.
if (typeof(Module['_emscripten_futex_wake']) !== "function") {
err("Thread Initialisation failed.");
throw e;
}
Module['_emscripten_futex_wake'](threadInfoStruct + 0 /*C_STRUCTS.pthread.threadStatus*/, 0x7FFFFFFF/*INT_MAX*/); // Wake all threads waiting on this thread to finish.
if (!(e instanceof Module['ExitStatus'])) throw e;
}
}
// The thread might have finished without calling pthread_exit(). If so, then perform the exit operation ourselves.
// (This is a no-op if explicit pthread_exit() had been called prior.)
if (!noExitRuntime) PThread.threadExit(result);
} else if (e.data.cmd === 'cancel') { // Main thread is asking for a pthread_cancel() on this thread.
if (threadInfoStruct) {
PThread.threadCancel();
}
} else if (e.data.target === 'setimmediate') {
// no-op
} else if (e.data.cmd === 'processThreadQueue') {
if (threadInfoStruct) { // If this thread is actually running?
Module['_emscripten_current_thread_process_queued_calls']();
}
} else {
err('worker.js received unknown command ' + e.data.cmd);
console.error(e.data);
}
} catch(e) {
console.error('worker.js onmessage() captured an uncaught exception: ' + e);
console.error(e.stack);
throw e;
}
};
// Node.js support
if (typeof process === 'object' && typeof process.versions === 'object' && typeof process.versions.node === 'string') {
// Create as web-worker-like an environment as we can.
self = {
location: {
href: __filename
}
};
var onmessage = this.onmessage;
var nodeWorkerThreads = require('worker_threads');
Worker = nodeWorkerThreads.Worker;
var parentPort = nodeWorkerThreads.parentPort;
parentPort.on('message', function(data) {
onmessage({ data: data });
});
var nodeFS = require('fs');
var nodeRead = function(filename) {
return nodeFS.readFileSync(filename, 'utf8');
};
function globalEval(x) {
global.require = require;
global.Module = Module;
eval.call(null, x);
}
importScripts = function(f) {
globalEval(nodeRead(f));
};
postMessage = function(msg) {
parentPort.postMessage(msg);
};
if (typeof performance === 'undefined') {
performance = {
now: function() {
return Date.now();
}
};
}
}