Reporting of loads w/o needing an HVAC system #1746

Open
shorowit opened this issue Jun 11, 2024 · 2 comments
Open

Reporting of loads w/o needing an HVAC system #1746

shorowit opened this issue Jun 11, 2024 · 2 comments
Labels
enhancement New feature or request priority low

Comments

@shorowit
Copy link
Contributor

shorowit commented Jun 11, 2024

We could use an EnergyPlus ideal air system, though doing so would mean that you can't get floating temperatures in the conditioned space. So this would probably have to be optional.

@shorowit shorowit added priority low enhancement New feature or request labels Jun 11, 2024
@shorowit
Copy link
Contributor Author

shorowit commented Jun 11, 2024

Thinking about it some more.... if you have an HPXML with just a heating system and you were to add an ideal air system for cooling, that would affect how much heating you do (since the conditioned space will now be maintaining the cooling setpoint). So there are definitely some tradeoffs here...

@Sashadf1
Copy link
Collaborator

Sashadf1 commented Oct 7, 2024

We are using an E+ ideal air system along w/ the DOE Commercial Reference Prototype models from openstudio-standards to report loads. You may be able to get floating temps by specifying an availability schedule for the ideal air system that isn't 24/7.