Notifications
You must be signed in to change notification settings - Fork 6
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Feature #17 eclass application classification classes #33
Feature #17 eclass application classification classes #33
Conversation
Merge with master of admin-shell-io
merge with fork master
How to reference an ECLASS application or classification class? admin-shell-io#17
Check again, after talking with ECLASS experts |
Check wether the asset category of the Technical Data submodel template can be used. |
Referencing of application and classification classes is no different to referencing the ECLASS property definition. | ||
Since classification and application classes correspond to a set of properties they can be used to describe the semantics of a complete submodel or of an SubmodelElementCollection. | ||
|
||
Please be aware: to be completeley unambiguous it is either necessary to model the complete hierarchy in the submodel or by using a semanticId with more than one IRDI. The keys in the reference are ordered. |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
In ECLASS a classification class can only be contained in exactly another classification class. IEC61360 would also allow that a classification class is member of more than one other classification class. So for ECLASS property together with its parent classification class is sufficient for a unique semanticId. ==> change example
For example the semanticId of a submodel containing the properties for the asynchronous servo motor without any further hierarchical modelling would be: | ||
|
||
|
||
<aas:semanticId> |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
formatting not correct, should be aas:semanticId
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
2021-05-03: reviewed in Exemplary Modelling WG - no final decision on how to deal with the problems. See comments added to example.
|
||
|
||
|
||
(Answered: 2021-01-11) |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Add a reference to the screencast #53 of https://admin-shell-io.com/screencasts/
on hold -> waiting for a joint publication of ECLASS and PI4.0 |
Q: Should one use application classes in define semantics of a submodel? |
question will be re-formulated based on the discussion on 1.8. |
* Update README.md fixes #33 * Update README.md typos
How to reference an ECLASS application or classification class? #17