Skip to content

Commit 068ef84

Browse files
committed
Templates update for release evcc-io/evcc@733a384
1 parent 2a4dd13 commit 068ef84

File tree

6 files changed

+216
-6
lines changed

6 files changed

+216
-6
lines changed
Lines changed: 72 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,72 @@
1+
template: lg-therma
2+
product:
3+
identifier: lg-therma-v-r290-monobloc-sg-ready
4+
brand: LG
5+
description: Therma V R290 Monobloc (SG Ready)
6+
group: Wärmeerzeuger
7+
description: |
8+
Modbus Verbindung zur LG Therma V Wärmepumpe.
9+
Funktioniert über SG Ready Energiezustände für intelligente Steuerung.
10+
Inneneinheit/Fernbedienung in den erweiterten Einstellungen > "Konnektivität" > "Energiezustand" > "Signaltyp" > auf "Modbus" einstellen.
11+
Da die interne Energiemessung zu hohe Werte anzeigt ist eine externe Energiemessung empfohlen.
12+
Werkseinstellung Modbus Addresse(HEX) = 21 (33).
13+
Modbus Register sind im Installationshandbuch zu finden (Adresse jeweils ohne die führende Ziffer und -1).
14+
Informationen zu den Energiezuständen finden sich auch im Installationshandbuch.
15+
Die Energiezustände 6 und 7 können an der Inneneinheit in den erweiterten Einstellungen > "Konnektivität" > "Energiezustand" > "Definition der Energiezustände" angepasst werden.
16+
17+
render:
18+
- default: |
19+
type: template
20+
template: lg-therma
21+
22+
# RS485 via adapter (Modbus RTU)
23+
modbus: rs485serial
24+
id: 33
25+
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
26+
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
27+
comset: "8N1" # Kommunikationsparameter für den Adapter
28+
29+
# RS485 via TCP/IP (Modbus RTU)
30+
modbus: rs485tcpip
31+
id: 33
32+
host: 192.0.2.2 # Hostname
33+
port: 502 # Port
34+
tempsource: water_tank # DHW Warmwassertank- oder Wassereinlasstemperatur, [water_tank, water_inlet]
35+
energystate: SGReady # SGReady oder anpassbare Energiezustände 6 und 7, [SGReady, IndividualEnergystate]
36+
params:
37+
- name: modbus
38+
example:
39+
default:
40+
choice: ['rs485']
41+
unit:
42+
description: Modbus Typ
43+
help:
44+
advanced: false
45+
optional: true
46+
- name: tempsource
47+
example:
48+
default: water_tank
49+
choice: ['water_tank', 'water_inlet']
50+
unit:
51+
description: DHW Warmwassertank- oder Wassereinlasstemperatur
52+
help:
53+
advanced: false
54+
optional: false
55+
- name: energystate
56+
example:
57+
default: SGReady
58+
choice: ['SGReady', 'IndividualEnergystate']
59+
unit:
60+
description: SGReady oder anpassbare Energiezustände 6 und 7
61+
help:
62+
advanced: false
63+
optional: false
64+
modbus:
65+
baudrate: 9600
66+
comset: 8N1
67+
device: /dev/ttyUSB0
68+
host: 192.0.2.2
69+
id: 33
70+
port: 502
71+
rs485serial: true
72+
rs485tcpip: true
Lines changed: 33 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,33 @@
1+
template: sigenergy
2+
product:
3+
identifier: sigenergy-evac-series
4+
brand: Sigenergy
5+
description: EVAC series
6+
capabilities: ["mA"]
7+
requirements: ["sponsorship"]
8+
render:
9+
- default: |
10+
type: template
11+
template: sigenergy
12+
13+
# Modbus TCP
14+
modbus: tcpip
15+
id: 1
16+
host: 192.0.2.2 # Hostname
17+
port: 502 # Port
18+
params:
19+
- name: modbus
20+
example:
21+
default:
22+
choice: ['tcpip']
23+
unit:
24+
description: Modbus Typ
25+
help:
26+
advanced: false
27+
optional: true
28+
modbus:
29+
host: 192.0.2.2
30+
id: 1
31+
modbus: tcpip
32+
port: 502
33+
tcpip: true

templates/release/de/tariff/energinet.yaml

Lines changed: 3 additions & 3 deletions
Original file line numberDiff line numberDiff line change
@@ -1,4 +1,4 @@
1-
template: energinet
1+
template: energinet-price
22
product:
33
identifier: energinet
44
brand: Energinet
@@ -8,11 +8,11 @@ requirements: ["skiptest"]
88
render:
99
- default: |
1010
type: template
11-
template: energinet
11+
template: energinet-price
1212
region: dk1 # Region, [dk1, dk2]
1313
advanced: |
1414
type: template
15-
template: energinet
15+
template: energinet-price
1616
region: dk1 # Region, [dk1, dk2]
1717
charges: # Aufschlag, Zusätzlicher fester Aufschlag pro kWh (z.B. 0.05 für 5 Cent) (optional)
1818
tax: # Steuer, Zusätzlicher prozentualer Aufschlag (z.B. 0.2 für 20%) (optional)
Lines changed: 72 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,72 @@
1+
template: lg-therma
2+
product:
3+
identifier: lg-therma-v-r290-monobloc-sg-ready
4+
brand: LG
5+
description: Therma V R290 Monobloc (SG Ready)
6+
group: Heating devices
7+
description: |
8+
Modbus connection to LG Therma V heat pump.
9+
Uses SG Ready energy states for intelligent control.
10+
Set the indoor unit in the installer settings > "Connectivity" > "Energy state" > "ESS use type" > to "Modbus".
11+
Since the internal power measurement shows to high values, an external power measurement is suggested.
12+
Factory setting Modbus (HEX) = 21 (33).
13+
Modbus registers can be found within the installation manual (address without the leading number and -1).
14+
Information on the energy state can be found within the installation manual.
15+
Energy states 6 and 7 can be adapted at the indoor unit in the installer settings > "Connectivity" > "Energy state" >"Energy state definition".
16+
17+
render:
18+
- default: |
19+
type: template
20+
template: lg-therma
21+
22+
# RS485 via adapter (Modbus RTU)
23+
modbus: rs485serial
24+
id: 33
25+
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
26+
baudrate: 9600 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
27+
comset: "8N1" # Kommunikationsparameter für den Adapter
28+
29+
# RS485 via TCP/IP (Modbus RTU)
30+
modbus: rs485tcpip
31+
id: 33
32+
host: 192.0.2.2 # Hostname
33+
port: 502 # Port
34+
tempsource: water_tank # DHW warm water tank or inlet flow temperature, [water_tank, water_inlet]
35+
energystate: SGReady # SGReady states or modifyable energy state 6 and 7, [SGReady, IndividualEnergystate]
36+
params:
37+
- name: modbus
38+
example:
39+
default:
40+
choice: ['rs485']
41+
unit:
42+
description: Modbus Type
43+
help:
44+
advanced: false
45+
optional: true
46+
- name: tempsource
47+
example:
48+
default: water_tank
49+
choice: ['water_tank', 'water_inlet']
50+
unit:
51+
description: DHW warm water tank or inlet flow temperature
52+
help:
53+
advanced: false
54+
optional: false
55+
- name: energystate
56+
example:
57+
default: SGReady
58+
choice: ['SGReady', 'IndividualEnergystate']
59+
unit:
60+
description: SGReady states or modifyable energy state 6 and 7
61+
help:
62+
advanced: false
63+
optional: false
64+
modbus:
65+
baudrate: 9600
66+
comset: 8N1
67+
device: /dev/ttyUSB0
68+
host: 192.0.2.2
69+
id: 33
70+
port: 502
71+
rs485serial: true
72+
rs485tcpip: true
Lines changed: 33 additions & 0 deletions
Original file line numberDiff line numberDiff line change
@@ -0,0 +1,33 @@
1+
template: sigenergy
2+
product:
3+
identifier: sigenergy-evac-series
4+
brand: Sigenergy
5+
description: EVAC series
6+
capabilities: ["mA"]
7+
requirements: ["sponsorship"]
8+
render:
9+
- default: |
10+
type: template
11+
template: sigenergy
12+
13+
# Modbus TCP
14+
modbus: tcpip
15+
id: 1
16+
host: 192.0.2.2 # Hostname
17+
port: 502 # Port
18+
params:
19+
- name: modbus
20+
example:
21+
default:
22+
choice: ['tcpip']
23+
unit:
24+
description: Modbus Type
25+
help:
26+
advanced: false
27+
optional: true
28+
modbus:
29+
host: 192.0.2.2
30+
id: 1
31+
modbus: tcpip
32+
port: 502
33+
tcpip: true

templates/release/en/tariff/energinet.yaml

Lines changed: 3 additions & 3 deletions
Original file line numberDiff line numberDiff line change
@@ -1,4 +1,4 @@
1-
template: energinet
1+
template: energinet-price
22
product:
33
identifier: energinet
44
brand: Energinet
@@ -8,11 +8,11 @@ requirements: ["skiptest"]
88
render:
99
- default: |
1010
type: template
11-
template: energinet
11+
template: energinet-price
1212
region: dk1 # Region, [dk1, dk2]
1313
advanced: |
1414
type: template
15-
template: energinet
15+
template: energinet-price
1616
region: dk1 # Region, [dk1, dk2]
1717
charges: # Charge, Additional fixed charge per kWh (e.g. 0.05 for 5 cents) (optional)
1818
tax: # Tax, Additional percentage charge (e.g. 0.2 for 20%) (optional)

0 commit comments

Comments