This project leverages transfer learning techniques to classify intestinal audio recordings for detecting postoperative ileus (POI). By using pre-trained models from large-scale audio datasets, we address the challenge of limited medical audio data (90 total samples).
- Limited Medical Data: Only 17 POI and 73 Non-POI samples
- Leverage Pre-trained Features: Models trained on millions of audio samples
- Better Generalization: Pre-trained models generalize better than training from scratch
- Faster Convergence: Fine-tuning requires less training time
- Type: Custom architecture with learnable kernels
- Pre-training: Not pre-trained, but uses transfer learning principles
- Architecture: 12 mixed-size kernels (0.5s, 1.0s, 2.0s)
- Parameters: 112K (prunable to 84K)
- Best Performance: 76.5% accuracy, 84.6% NPV
- Type: CNN-based transfer learning
- Pre-trained on: AudioSet (2M+ audio clips)
- Architecture: CNN14 with 14 convolutional layers
- Fine-tuning Strategy:
- Freeze early layers
- Fine-tune final layers
- Custom classification head for POI detection
- Type: MobileNet-based audio classifier
- Pre-trained on: AudioSet (521 classes)
- Architecture: MobileNetV1 adapted for audio
- Transfer Learning:
- Extract embeddings
- Add custom dense layers
- Fine-tune with medical data
- Type: Vision Transformer for audio
- Pre-trained on: AudioSet and/or ImageNet
- Architecture: ViT-B/16 adapted for spectrograms
- Transfer Learning:
- Convert audio to spectrograms
- Use pre-trained vision transformer
- Fine-tune for binary POI classification
Total Samples: 90
- POI (Positive): 17 samples (18.9%)
- Non-POI (Negative): 73 samples (81.1%)
Audio Format:
- Sample Rate: 8 kHz
- Duration: 4 minutes per file
- Processing: 20-30 second segments
# Common preprocessing for all models
- Load 8kHz WAV files
- Segment into model-specific lengths
- Convert to spectrograms/mel-spectrograms
- Normalize based on pre-training statistics# General approach
1. Load pre-trained model
2. Freeze early/middle layers
3. Replace final classification layer
4. Fine-tune on POI dataset
5. Apply regularization (dropout, weight decay)- Weighted Loss: BCEWithLogitsLoss with pos_weight
- Cost-Sensitive Learning: Various ratios (1.5, 2.0, 2.5, 3.0)
- Stratified Splits: Maintain class distribution
| Model | Config | Accuracy | NPV | Sensitivity | Training Time |
|---|---|---|---|---|---|
| SMOLK | Original | 76.5% | 84.6% | 50% | 80 min |
| PANNs | Simple | TBD | TBD | TBD | 15 min |
| PANNs | Cost-Sensitive (2.5) | TBD | TBD | TBD | 20 min |
| YAMNet | Transfer Learning | TBD | TBD | TBD | 10 min |
| YAMNet | Cost-Sensitive | TBD | TBD | TBD | 12 min |
| AST | Simple | TBD | TBD | TBD | 45 min |
| AST | Cost-Sensitive | TBD | TBD | TBD | 50 min |
smolk_implementation.py- SMOLK modelpanns_simple_gpu.py- PANNs baselinepanns_cost_sensitive.py- PANNs with class weightingyamnet_transfer_learning.py- YAMNet transfer learningyamnet_cost_sensitive.py- YAMNet with cost sensitivityast_simple.py- AST baselineast_cost_sensitive.py- AST with class weighting
final_model_comparison.py- Compare all modelsfinal_comparison_visualization.py- Generate plotsvisualize_all_confusion_matrices.py- Confusion matrices
results/directory contains JSON files with metrics
# Deep Learning Frameworks
torch>=2.0.0 # SMOLK, PANNs, AST
tensorflow>=2.13.0 # YAMNet
transformers>=4.30.0 # AST
# Audio Processing
librosa>=0.10.0
soundfile>=0.12.0
scipy>=1.10.0
# Machine Learning
scikit-learn>=1.2.0
numpy>=1.24.0
pandas>=2.0.0
# Visualization
matplotlib>=3.7.0
seaborn>=0.12.0- Minimum: 8GB RAM, CPU only
- Recommended: 16GB RAM, GPU (NVIDIA CUDA or Apple MPS)
- Optimal: 32GB RAM, High-end GPU for AST
- Edge Devices: YAMNet (smallest, fastest)
- Cloud API: AST (highest accuracy)
- Balanced: PANNs (good accuracy, reasonable size)
- Interpretable: SMOLK (learnable kernels)
- Model quantization (INT8)
- ONNX conversion for cross-platform
- TensorFlow Lite for mobile
- Batch processing for efficiency
- Initial Screening: Use ensemble of best models
- Risk Stratification:
- High NPV (>85%) → Low risk
- Low NPV → Requires clinical review
- Continuous Monitoring: Re-test every 4-6 hours
- Models are for screening support only
- Not FDA approved for diagnosis
- Always combine with clinical assessment
- Maintain prediction audit trail
- Ensemble methods combining all models
- Data augmentation techniques
- Cross-validation with different seeds
- Hyperparameter optimization
- Multi-site validation
- Real-time inference pipeline
- Integration with hospital systems
- FDA 510(k) submission prep
- Continuous learning from new data
- Multi-class severity prediction
- Combination with other vitals
- Clinical trial for diagnostic approval
- Kong et al. (2020) - "PANNs: Large-Scale Pretrained Audio Neural Networks"
- Hershey et al. (2017) - "CNN Architectures for Large-Scale Audio Classification"
- Gong et al. (2021) - "AST: Audio Spectrogram Transformer"
- Chen et al. (2024) - "SMOLK: Sparse Mixture of Learned Kernels"
Last Updated: August 2025 Status: Transfer Learning Implementation Complete