Description
Maybe it is already there or could be achieved via other measures.
I am looking for something like a temp based max charge current.
0Celsius: 0c (c-rate)
5C:0.05c
10C:0.7c
20C:1c
30C:1c
40C:0.75c
45C:0.5c
50C:0c
means mac current based on temp & capacity of connected batteries. Current curve between given point could be linear interpolation.
Always minimum of configured algo and this curve (via config file) should be used.
Asking for it as my battery is located in a garage and in winter it could go down to 5Celsius maybe even ~0C. Did never check so far if the resistence based algo will also result in far lower max current at low temps. currently (at 10C) I see 210A CCL and 314A DCL. Which is so far OK (1800Ah connected) but what happens if only one pack would be connected due to maintenance...