What a consumer outside this repository can depend on, and every change to it. That is four things:
- the manifest format (
format:in every file, named by schema v1); - the published build under
library/dist/, whosedevices.jsoncarries acontractnumber; - the DCIM exports under
library/exports/, which carry no number of their own, so a change that re-files data already imported is marked BREAKING for DCIM data already imported; - the addresses a manifest outside this tree holds: a component major it
pins (
name@2), and a lint code it waives.
A number goes up when something a reader depends on is removed, renamed, or changes meaning. Adding a field does not move it: a consumer that ignores a new key is unaffected, and one that wants it can look. docs/format-stability.md states the rules in full.
The hardware itself is versioned per device (device.lock.json beside each
manifest) and per component (version: in each contract), and those versions
are not repeated here, except where a component major is removed: every removal
names the ref that replaces it.
What does not move from 0.1.0: manifests are still format: 1 and the
published build is still contract: 2. No lint code was renumbered or
reused; L125 to L172 are new. What a reader coming from 0.1.0 has to act on
is marked BREAKING or ONE-WAY in its entry, and every component major
that was removed is under Removed with the ref that replaces it.
The entries were written as each change merged, so some describe a state that a later change in this release overtook. Such an entry is kept, and a Superseded clause in it says what is true at 0.2.0.
Routed lengths on a saved rack changed in steps, and the entries under
Changed list them out of order. In order they are: through a D-ring
(@portrayal/kit 0.5.0), beside a duct (0.6.0), along a bundle's trunk
(0.7.0), round solid bodies and a zero-U PDU (0.11.0), along one manager
(0.12.0), from the plug's reach (0.13.0), at rest on trays and sills
(0.14.0), into a ring through its opening (0.15.0), the per-media end
allowance (0.16.0) and bend room (0.17.0). Each entry measures its change
against the kit before it. None of them reaches a consumer of 0.1.0: the
rack modules and the rack file are new in this release.
The kit versions this section names are versions of kit/package.json in
this repository. @portrayal/kit on npm is 0.2.0, which has no rack module.
@portrayal/index is not on npm at this tag, so packageDist and
?dist=cdn have no index to read until it is.
components.jsoncarries the catalogue's derived columns on each entry (one entry per component major, one row oflibrary/components/CATALOGUE.md):seats, the number of devices that seat it (the page'sdevicescolumn);composed-by, the number of other component majors that compose it (the page'sin partscolumn, the reverse ofparts); and the contract'sinterfaceandmates, besideconforms, when it states them. The page and the index are counted by the same functions incomponents_catalogue.py. Additive; thecontractnumber does not move.- The FS FHD-CMP5DR lacer panel (
fs/fhd-cmp5dr), the first passive part that shares a rack unit with other equipment, and what it needs:chassis.mount: rack-face(a part bolted to the rail face that projects outward; it statesru, the units its ears span, and exportsu_height: 0);chassis.shell: sheetwithchassis.thickness, a bent sheet-metal body whose views are elevations and which builds in 3D only what its parts build (lint L127 holds a sheet to its gauge); and apassiveprofile for rack furniture, which owes only its weight. Apassivedevice is exported to DCIM though it has no interfaces, console or bays. Design note:docs/cable-managers-design.md. - Lint L128, on devices and listings: a
part-numberskey has no stray whitespace. Whitespace other than a plain space (NBSP, a tab, a zero-width space) and leading or trailing whitespace are errors; a space splitting a run of capitals and digits between two hyphens (9716-32D-O-A C-F-UK, #720) is a warning a device can waive. Keys that mean their spaces, such asAS7535-28XB-O-AC-F V2and7750 SR-12 (pre-2016 chassis), pass, and nothing in the library raises it (#731). - Fibrain's HD adapter holders for LC, and the multimode SC ones: ten LC
duplex holders (
fibrain/xmi1021ca,-da,-ha,-gaandxmi1031gawith 6 adapters;xmn1021cb,-db,-hb,-gbandxmn1031gbwith 12) and six SC holders in OM3, OM4 and OM5 (xmi1041ca,-da,-ha;xmn1041cb,-db,-hb). The XCU10 gains XCU10-21IC and XCU10-31IC, its 24-adapter LC and LC/APC variants, and its drawer's slots accept all twenty holders. As with the SC holders, these seat in bays of the drawer's module type, which NetBox takes (4.5.7 or later) and Nautobot is not given: none of their ports can be placed in Nautobot yet (#834; superseded by the Nautobot entry under Changed, which gives the drawer its bays). The 12-port LC holders are the first modules to stateoptical.front-orderby position: their lower row is turned over, and its ports still count left to right. optical.front-ordermay name one position of a part (lc07.2) as well as a part. A duplex adapter turned over, as in the lower row of a belly-to-belly holder, has its bore 1 on the other hand, and listing its positions in the order they are numbered (lc07.2, lc07.1) makes the exported front ports and fibre map count along the row. A part named bare counts 1 upward as before, so no existing module changes. Lint L78 holds such a part to naming every position once, together.- MRJ21, VHDCI and RJ11 jacks are connector slots, and three cable plugs seat
in them.
mrj21,vhdciandrj11joinspec/schemas/connectors.yaml, so everystd/mrj21@1,common/vhdci-receptacle@1andcommon/rj11-jack@1publishes akind: connectorslot: nested on the Nokia M48-1GB-XP-TX MDA and on the three Oscilloquartz HD cards, and on the Halny HLX-TGV chassis.common/vhdci-receptacle@1andcommon/rj11-jack@1gain their interface, and the RJ11 jack amatepoint; no drawing changed, and the three cards and five devices that carry them take a patch.generic/mrj21-plug@1,generic/vhdci-plug@1andgeneric/rj11-plug@1are the straight cable plugs that mate them, each with a 30 mm stub of cable sized bycable-odand coloured byjacket-color. The MRJ21 plug and the VHDCI hood are scaled from drawings that dimension neither; seedocs/connectors-mrj21-vhdci-rj11-design.md(#790). - Ground studs seat a ring lug.
common/ground-lug@1,common/ground-stud@1andjuniper/mx-ground-stud@1each gaininterface: terminal-studand amatepoint on the stud axis, on top of what the part builds, so every placement of one is a slot of its device that offersgeneric/ring-lug@1. The three studs ofcasa/c40g-ground-studs@1are nowcasa/shelf-ground-stud@1, composed asstud-tr,stud-blandstud-br, each a nested slot. No drawing changed. A placement statesstud-size(M4,M5,M6,10-32,1/4-20,1/4 in) where a document for its device states the size of the stud or screw: 68 placements on 31 devices, each with its source inprovenance.ground-stud-size. The 53 devices that place one of the four parts take a patch; their DCIM exports change in the drawing version line only. The lug is the one nominal lug and is not turned: where it overhangs a face, or two lugs on a pair overlap, is recorded indocs/connectors-dc-terminal-design.md, section 13, with a two-hole lug as later work (#789). - Two more of the Amphenol Network Solutions 300CB08 family, the passive
connectorized panels:
amphenol-ns/300cb08-sc(stud inputs) andamphenol-ns/300cb08-c(horizontal busbar inputs). Each replaces the screw terminal outputs with sixteenamphenol-ns/output-p40@1receptacles; the -C takes its feeds onamphenol-ns/input-feed-busbar@1, whose landings stand 147 mm behind the chassis (superseded: the -C panels under Fixed put them 38.1 and 95.2 mm behind a 367.0 mm deep panel, #860). Front, top, bottom and sides are the 300CB08. In the DCIM exports each has twodc-terminalpower ports, one per feed, and its outputs are not exported yet. Superseded: the power outlets entry in this section exports them, sixteen outlets labelledP40on each (PR #849). No existing device or export changes. - The two monitored panels of the Amphenol Network Solutions 300CB08 family
with the plain rear:
amphenol-ns/nrg300cb08-ctrl(integrated nrgSMART controller: front displayamphenol-ns/nrg-oled@1, MGMT and LAN RJ45s, RESET) andamphenol-ns/nrg300cb08-sens(sensor card, no network jacks). Both take the new rear centreamphenol-ns/nrg-rear-block@1(alarm headers, nrgNET IN and OUT, two temperature probe jacks), which the DCIM exporter skips as not a DCIM port. In the DCIM exports the CTRL has two management interfaces,mgmtandlan(100base-tx), and both have twodc-terminalpower ports. No existing device or export changes. - Fibrain, a new vendor: the XCU10 extendable HD patch panel (
fibrain/xcu, 0.5U, 48 SC), with XCU10-51ID and XCU10-41ID as configurations. Its front is one captive drawer (fibrain/xcu-drawer@1) whose four slots seat the HD adapter holders XMI1041GA and XMI1051GA (6 SC, 6 SC/APC), XMN1041GB and XMN1051GB (12 SC, 12 SC/APC) or the XBCS0 blind cover.common/sc-simplex-adapter@1is new: one SC port to a body, with no dust cap seated. These are the first parts to useshape: ringandshowson body pieces. In the DCIM exports the holders seat in bays of the drawer's module type, which NetBox takes (4.5.7 or later) and Nautobot is not given: the Nautobot drawer has no bays, so the holders and their 48 ports cannot be placed there yet (#834; superseded by the Nautobot entry under Changed, which gives the drawer its four bays). Nautobot statesu_height: 1for this 0.5U panel. - The explorer edits a part's fields. Selecting a part whose component
declares
fields:- a supply's wattage, a latch colour, a filter's channel numbers - shows one control per field in the inspector: a list for achoice, an input otherwise, starting from the value the configuration built. A change is written withsetFields, in 2D and 3D, is kept across a view change, goes when the part is swapped out, and is carried in the page's location asfields=<path>~<key>~<value>,...besideswap=. A value the field does not take is not written, from the form or from a link. A link restores a field only for a part drawn on the view it opens; one set on another view is dropped on reload (#818).kit/fields.jsgainsfieldRows,fieldAccepts,encodeFields,decodeFieldsanddrawnField, and the shell gainsresetFieldandapplyFields(#811). - Barrier terminal blocks seat a lug per pole.
terminal-studjoinsspec/schemas/connectors.yamlas one nominal connector: a screw or stud terminal a lug lands on, claiming no size. The terminal screws ofcommon/dc-terminal-24@1andcommon/dc-terminal-27@1(1.0.1) are now parts of their own,common/terminal-screw-34@1andcommon/terminal-screw-38@1, composed aslug-1tolug-3; each presents the interface, so each pole is a nested slot (psu1-input/lug-2, orpsu-1/terminal/lug-2on a Telco Systems DC supply). The blocks draw exactly as before and keep every id.generic/ring-lug@1is the one-hole insulated ring terminal that seats there, on a 10 mm stub of wire lying in the plane of the face;wire-colorandbarrel-colorpaint it. It is a nominal lug for 16 to 14 AWG wire, not the lug of any one device. The Edgecore CSR180 and CSR200 and the Telco Systems TM-8104 and TM-8106 take a patch. Seedocs/connectors-dc-terminal-design.md, section 12. - Pluggable terminal headers are connector slots, and three screw-clamp plugs
seat in them.
terminal-508-2,terminal-508-5andterminal-508-6joinspec/schemas/connectors.yaml.common/terminal-header-508-2@1,common/terminal-header-508-5f@1andcommon/dc-terminal-header-6@1(1.0.1, the five-position header 1.0.2) gain their interface and amatepoint; no drawing changed, and the 11 devices that draw one take a patch. Superseded for two of the three headers:@1of each was removed later in this release, and the majors to pin at 0.2.0 arecommon/terminal-header-508-2@3andcommon/terminal-header-508-5f@2(under Removed).generic/terminal-508-2-plug@1,generic/terminal-508-5-plug@1andgeneric/terminal-508-6-plug@1are the plugs that mate them, drawn from the wire side with one 30 mm stub of wire per pole and awire-1towire-Npoint on each.wire-odsizes every stub,wire-colorpaints every stub andbody-colorpaints the body. Each stands 10 mm in front of the face its header presents; seedocs/connectors-dc-terminal-design.md.terminal-508-5is the five-position mating face with or without flanges; the plug drawn is the screw-flange form (#789). - The DC barrel jack is a connector slot, and a barrel plug seats in it. The
library treats the jack as one nominal connector,
dc-barrel: barrel diameters vary by product and no document held for a device that places one states its size.common/dc-barrel@1(1.0.1) gains the interface and amatepoint besidepower; its drawing is unchanged, and the four devices that place it take a patch. Each placement now statesinput-voltageandcurrent-max-afrom its device's documents.generic/dc-barrel-plug@1is drawn at the common 5.5 mm barrel from one manufacturer's drawing, with a 30 mm stub of cable sized bycable-od; it states no rating and claims to be no device's own plug (#789). - A component's body pieces (
body.boxes) can be round and can carry a drawing.shape: cylinderorring(withaxis, andwallon a ring) builds a round piece in the envelope a box would fill;shows: [plan]or[rear]paints a box piece's top or back with the patch of the part's ownfaces.planorfaces.reardrawing it covers.components.jsongainsbody.drawingsandbody.faceon a part whose pieces show one. Lint L71 checks the new keys. Nothing existing changes: a piece that states neither is the plain box it was. - The Cisco Nexus 93180YC-EX (
cisco/n9k-c93180yc-ex): 48 SFP28 and 6 QSFP28 on the port side; two supplies, four fan modules, console, both management ports and USB on the other; port-side intake and port-side exhaust configurations. Two new parts seat in it,cisco/nxa-pac-650w@1andcisco/nxa-fan-30cfm@1, each covering both airflow part numbers through a latch-colour field. - The Cisco Catalyst 4948E (
cisco/ws-c4948e), the front-to-back build: 48 10/100/1000 RJ-45 and 4 SFP+ on the front with the console and management jacks and the status lamps; two supplies and the fan tray on the rear. Two new parts seat in it,cisco/pwr-c49e-300ac-r@1andcisco/ws-x4993@1. Its export names ports as IOS does,GigabitEthernet1/1to1/48,TenGigabitEthernet1/49to1/52andFastEthernet1. - The Smartoptics DCP-1203 (
smartoptics/dcp-1203@1), three 100/400G transponders on one DCP-2 traffic unit: six QSFP28/QSFP-DD combo cages in three pairs, odd ports client and even ports line, each with its Tx and Rx lamps. The DCP-2 accepts it in both traffic slots and gains adcp-1203-x2example configuration. - A device can name its own interfaces. A top-level
interfaces:block, in the shape a NOS listing's has, says what the maker's own operating system calls each port, and the hardware's own DCIM device type uses those names: the Nexus exportsEthernet1/1toEthernet1/54and onemgmt0. An id no rule names keeps its faceplate id, and a listing's names still decide that listing's document. The lock records the names and asks a major bump when one changes; L105 refuses a rule that names nothing the device places. - Amphenol Network Solutions, a new vendor (
amphenol-ns, formerly Telect): the 300CB08 (amphenol-ns/300cb08), a 1RU dual-feed DC circuit breaker panel with sixteen plug-in positions, all six faces, and elevenamphenol-ns/parts. A position takesamphenol-ns/breaker-1ru@1, one module for every rating from 2 A to 60 A, set per position by itsratingfield and printed on its handle;amphenol-ns/tpa-fuse-holder-307492@1, which carries its fuse as afuse-ratingfield; or the blanking cover. A breaker ships wearingamphenol-ns/touch-guard-1ru@1, a separate part seated on it that comes off:spec/schemas/connectors.yamlgainsbreaker-1ru-guard, markedcover: true, the first slot that is a cover mount and not a connector. It is the first power distribution device:spec/schemas/profiles.yamlgains apowerprofile, which owes an input rating, the panel's own draw and an operating temperature and noperformanceorplatformsection, andspec/schemas/power-roles.yamlgains the classbreakerunderpassive, for any removable circuit protector. In the DCIM exports each feed is onedc-terminalpower port (input-a,input-b) and each position is a module bay; the sixteen output circuits and the alarm contacts are not exported yet. No existing device or export changes. Superseded for the outputs: the power outlets entry in this section exports them as sixteendc-terminalpower outlets (PR #849). The alarm contacts are still not exported. The family is eleven panels at 0.2.0, seven of them with P40 outputs, and each exports sixteen power outlets. An entry in this section that counts ten panels, or six with P40 outputs, counts the family before the nrgILS300CB08-SC joined it. - CFP, CFP2, CFP4 and CXP cages offer optics.
generic/cfp-lc@1,generic/cfp-sc@1,generic/cfp-mpo@1,generic/cfp2-lc@1,generic/cfp2-mpo@1,generic/cfp4-lc@1,generic/cfp4-mpo@1andgeneric/cxp-mpo@1are the first parts to matecfp,cfp2,cfp4andcxp, so theacceptslist of every such cage incomponents.json, and in a<device>.configs.jsonthat seats a card carrying one, goes from empty to these. Each publishes its receptacle as a connector slot.common/cfp-thumbscrew@1is the knob the CFP parts compose, andstd/mpo24-module-receptacle@1the two-row MPO mouth the twenty-four-fibre faces compose.spec/schemas/standards.yamlgainscfp-module,cfp2-module,cfp4-moduleandcxp-module, each with thehead:envelope its standard gives. No cage contract and no DCIM export changes. docs/pluggables-cfp-cxp-design.md. - OSFP and XFP cages offer optics.
generic/osfp-mpo16@1,generic/osfp-lc@1andgeneric/xfp-lc@1are the first parts to mateosfpandxfp, so theacceptslist of every OSFP and XFP cage in<device>.configs.jsonandcomponents.jsongoes from empty to these. Each publishes its receptacle as a connector slot.common/osfp-pull-tab@1is the tab the OSFP parts compose.spec/schemas/standards.yamlgainsosfp-moduleandxfp-module, each with thehead:envelope its MSA gives. No cage contract and no DCIM export changes. docs/pluggables-osfp-xfp-design.md. - D-subminiature and VGA panel connectors are connector slots, and four hooded
cable plugs seat on them.
db9,hd15,da15anddb25joinspec/schemas/connectors.yaml, each naming the connector with the gender the library draws on a panel (the DE-9 male, the other three female), so everystd/db9@1,std/vga@1,std/da15@1andstd/db25@1publishes akind: connectorslot: on a chassis, on a card seated in a bay, and throughcommon/db9-receptacle@1andcommon/vga-receptacle@1. No existing part or device changed.generic/db9-plug@1(female),generic/hd15-plug@1,generic/da15-plug@1andgeneric/db25-plug@1(male) are the cable plugs that mate them, drawn from the cable end with their two thumbscrews and a 30 mm stub of cable sized bycable-odand coloured byjacket-color. The moulded VGA hood takeshood-color, blue by default as the port is. Each seats with its flange the mating dimension in front of the panel connector; seedocs/connectors-dsub-design.md(#787). - USB receptacles are connector slots, and three cable plugs seat in them.
usb-a,micro-usb-bandusb-cjoinspec/schemas/connectors.yaml, so everystd/usb-a@1,std/micro-usb@1andstd/usb-c@1publishes akind: connectorslot: on a chassis, on a card seated in a bay, and through thecommon/usb-a@2andcommon/usb-a-bezel@1bezels.std/micro-usb@1(1.0.1) gains its interface and amatepoint; its drawing is unchanged, and the 39 devices that draw it take a patch.generic/usb-a-plug@1,generic/micro-usb-b-plug@1andgeneric/usb-c-plug@1are the moulded cable plugs that mate them, drawn from the cable end at the largest overmould the USB specifications allow, with a 30 mm stub of cable sized bycable-odand coloured byjacket-color. Each seats to the insertion its USB drawing gives; seedocs/connectors-usb-design.md. No receptacle's geometry changed (#786). - AC power inlets are connector slots, and three cord ends seat in them.
iec-c14,iec-c20andsaf-d-gridjoinspec/schemas/connectors.yaml, so everystd/c14-inlet@1,std/c20-inlet@1andstd/saf-d-grid@1publishes akind: connectorslot, on a chassis and on a supply seated in a bay alike.generic/c13-plug@1,generic/c19-plug@1andgeneric/saf-d-grid-plug@1are the moulded cord connectors that mate them, drawn from the cable end with a 30 mm stub of cord sized bycable-odand coloured byjacket-color. Each seats with its nose on the inlet's modelled cavity floor; seedocs/connectors-power-design.md. No inlet's geometry changed (#785). - Supermicro, a new vendor: the SuperServer SYS-111E-WR (
supermicro/sys-111e-wr, 1U, ten hot-swap 2.5 inch bays, two 860 W supplies), the SYS-111E-FDWTR (supermicro/sys-111e-fdwtr, 1U short-depth front I/O, two 600 W -48 V DC supplies) and its AC sibling the SYS-111E-FWTR (supermicro/sys-111e-fwtr, with the SYS-111E-FWTR-EU as itseuconfiguration), each with front, rear and a top view under a removable cover, and 23supermicro/parts. - A face's vents show from inside the chassis in 3D. Where an interior well
(
relief: {walls: inside}) has a side within 3 mm of a face, that side is painted with the face's declared air openings - decor that saysvent:orpattern: vent, which the compiled drawing carries asdata-aperture="air"- each in the place it has on the outside. Nothing is read off a colour: a dark rect that declares neither stays a plate.dell/r660andsupermicro/sys-111e-wrdeclare their rear vents (a patch each).relief.jsexportsfaceFrame,wellWallCorners,wallsAgainstFaces,wallUV,ventWellWallsandWALL_REACH. - Supermicro SuperServer SYS-511E-WR (
supermicro/sys-511e-wr): the 1U WIO server with four hot-swap 3.5 inch bays, front, rear and a top view under a removable cover, with its tray, control panel and cover parts; the Gold Series SKU SYS-511E-WR-01-G2 is itsgoldconfiguration. supermicro/riser-wio-rhs-x13sew@2replaces@1: slot 3's bracket bay moved 2.6 mm so the riser plate no longer covers the edge of a card's first cage. Both X13SEW risers gain a housing over the bracket flanges in 3D.supermicro/system-board-x13sew@2replaces@1: the board is flat art on the floor of one interior well per chassis (supermicro/interior-sc116b@1,-sc815b@1,-sc515b@1), so supplies, risers, fans and DIMMs stand in the chassis as bodies under the cover and leave it empty when ejected. The fan (supermicro/fan-0163l4@1) is drawn as the top of its housing, not as rotors, and the SYS-111E-WR's five fans are at their photographed positions. All four servers gain an air shroud and a supply cage cover under the lid, and the X13SEW risers declare their bodies in pieces - bracket arm, riser card and a connector for each slot - so seated cards show, plugged in.- 3D kit (
relief.jsejectTravel): a pulled part's travel limit is never less than its own depth plus the margin. From above a 1U chassis the limit was the chassis height less 10, 33 mm, and a 40 mm fan or a 31 mm DIMM never came clear of the lid. Parts pulled from the front or rear are unaffected unless they are within 20 mm of the chassis depth. plan: {rotate: 180}on a device bay: the plan of a module seated in a FRONT bay is turned half a turn in the top view, and the occupants of its own bays are offset from the opposite corner. A plan is drawn face-at-the-top, as a rear-seated module lies; the first front-I/O server needed the other way.- NetBox module types carry a module's own bays. A module that seats others -
a riser with PCIe slots, an MPC with MIC bays - exports them as
module-bays, each named and positioned{module}/<bay id>, which NetBox fills with the position of the bay the module itself sits in: a card in slot 2 of a riser inriser-primarynames its portriser-primary/slot-2/port-1. Nothing already imported is renamed. It needs NetBox 4.5.7 or later: before that the install forms refuse a card in a nested bay, and the REST API names its ports after the outer bay alone. The Nautobot module types are not given these bays, so from here the two trees underlibrary/exports/*/module-typesare no longer the same text: Nautobot writes a bay's position as given and cannot fill{module}in it (#765). Superseded by the Nautobot entry under Changed: most Nautobot module types carry their bays at 0.2.0, written plain, with the parent in the port names. The bays that entry lists as withheld (a carrier whose modules also seat directly in a chassis) are still not given. - Five generic optics, a plug and a pull handle:
generic/qsfp-mpo@1(a QSFP with one MPO receptacle),generic/qsfp-dd-mpo16@1(a QSFP-DD with one MPO-16 receptacle in a Type 2 nose),generic/qsfp-lc-simplex@1(a QSFP with a single LC bore),generic/sfp-sc@1andgeneric/sfp-sc-key-up@1(an SFP with an SC receptacle and a bail, key slot down and key slot up),generic/mpo16-plug@1(the sixteen-fibre MPO plug, key offset, matingmpo16) andcommon/qsfp-dd-pull-tab-type2@1(the shorter handle of a Type 2 QSFP-DD module).std/mpo-module-receptacle@1andstd/mpo16-module-receptacle@1draw the MPO mouth as a module carries it, with the pinned ferrule, the key notch and one addressable node per fibre. Each optic's receptacle is a connector slot offering its plug and dust cap. A new registry entry,mpo16-plug. A host's own field default now reaches a part it composes when the two defaults differ. See docs/pluggables-mpo-bidi-pon-design.md. - Nokia Lightspan MF-8 (
nokia/lmfs-f) with its NT board (nokia/lbnt-a), 16-port Multi-PON LT board (nokia/lwlt-c), alarm module (nokia/lalm-f), power module (nokia/lpwr-f), fan module (nokia/lfan-f), the LT and NT dummy boards and the horizontal front cover; the Nokia XS-010X-R and XS-010XR-P XGS-PON ONTs; and the outdoor ONT enclosure 3FE54221AH. - A device's built-in PON port now exports. A placement that states
ponwith a flavour both NetBox and Nautobot define leaves as that interface type; before, an ONT's SC/APC uplink exported nothing. This adds aponinterface (xgs-pon) to the four Halny HLX-TGV device types - an addition, so nothing already imported is re-filed. - Lint L76 counts a lamp bound to a jack from another face (
for: rear/lan), as it already counted one drawn beside the jack. - ReadyLinks GL-12xB-240D (
readylinks/gl-12xb-240d), the first device to seat a BNC jack: twelve ReadyLink ports oncommon/bnc-jack@1(impedance 75) on a new GL-x 12-port BNC line card in slot 1, a slot blank in slot 2, and two BNC sync jacks on the chassis, modelled from the vendor GLB. New componentsreadylinks/gl-x-lc-12xb@1,readylinks/gl-x-lc-blank@1,common/rocker-switch@1,common/dc-terminal-header-6@1andcommon/ground-stud@1.std/bnc@1andcommon/bnc-jack@1are no longerunplaced. chassis.mountin the device manifest:rack(the default),din-rail,wallordesktop. Lint L125 warns on a rack device with noruand refusesruon a box that is not racked (#734).chassis.bevelin the device manifest: edges named by the two faces that meet at them, cut back bysizemm - one number at 45 degrees, or a pair[a, b]taking a different amount off each face. A bevelled face'schassis-faceplateis a<path>of the solid's outline, its bevel strips are drawn inchassis-bevels, and<device>.configs.jsoncarries the solid's polygons aschassis.solidfor the 3D viewer (@portrayal/kitexports./bevel). Lint L126 checks the bevel and keeps parts on the flat face (#735).- Cables in the draw.io exports (#728):
rackDiagram,toDrawioanddiagramtakecables(a rack plan's{id, a: {item, path, view}, b, media, purpose, label, length}) and write each as an edge between two port cells. A cable whose ends are on different pages becomes a labelled stub on each; one with an end not drawn is listed in a notes comment with the reason.cableStylesets the colours, andrackCablesreturns the notes as a list. Withoutcablesthe output is unchanged. - An elements file beside every compiled face:
<device>[.<config>].<view>.elements.jsonlists each element the face draws, by itspath(oroffor a projection), with itsid,class,ref,media,speed,group,group-role,rel-pos,states,forandinner, its box and connection points in the face's millimetres, the bay or cage it is seated in, and itsparentin the Explorer's tree, under a header naming the device, configurations, view, viewBox,source-sha256and component versions. A server can read a face's tree without a DOM or a layout pass. The nesting rule moved out ofkit/shell.jsintofaceTreein@portrayal/kit/swap, which the Explorer and the build both follow; the Explorer's tree is unchanged. Each device's npm package carries its faces' elements files. The file is new, so the distcontractnumber is unchanged at 2; docs/format-stability.md gives its shape (#727). - Diagram exports in the kit:
@portrayal/kit/drawio,@portrayal/kit/omnigraffleand@portrayal/kit/zones, which were written for portrayal.dev and are now the kit's own. Each export is the face as a picture with one named, connectable shape per port and bay; draw.io gets a shape library, a rack elevation or a one-device.drawio, and OmniGraffle a.gstencil.toDrawio(svgRoot, doc)andtoGraffle(svgRoot, doc)export a LIVE drawing - optics seated, lamps lit, marks and a crop applied - and leave out the ports a crop cuts away. A face whose viewBox does not start at 0,0 (an optic's, or a crop) now has its draw.io ports where its picture is; they were offset by the viewBox origin. - Four more SONiC listings (#674): the Celestica DS1000,
DS2000 and DS3000 and the Edgecore AS4630-54TE (EPS201). SONiC builds for all
four in sonic-buildimage but its Supported Devices page predates them; the
build tree is taken as SONiC's list. Port names come from each platform's
table at the same pinned commit, joined by alias (
Eth33/1is port 33). npm_packages.py: the build split into npm packages, one per device (@portrayal/<vendor>-<device>), one for the component skins and one index carryingpackages.json(device → package and version, and a vendor → family → device tree). Each package is versioned from what npm last published, and only changed packages are published. Nothing indist/changes; seelibrary/README.md(#528).- SONiC listings (#674). The 17 boxes on SONiC's Supported
Devices and Platforms page that the library models are listed under
sonic/, every one with SONiC port names: each platform's own table in sonic-buildimage (port_config.ini, orplatform.jsonwith its breakout modes), pinned to one commit and joined to the faceplate by the port's alias- which names the front-panel port where
indexdoes not.eth0is the management port. Celestica's rows use codenames (DX010, Silverstone, Seastone_2) no document here ties to a DS model, so they wait.
- which names the front-panel port where
- DNOS listings (#674). The 13 modelled boxes the DNOS CLI
Reference Guide 26.2 accepts as NCP hardware (
system ncp model) are listed underdrivenets/, each named as DriveNets sells it -model: NCP-40C- and exported asDriveNets/NCP-40C (<SKU>), because one NCP name covers boxes from several ODMs. A listing may now settype-name, a pattern with{model}and{sku}, for exactly that. Six single-speed boxes carry DNOS port names (ge100-0/0/<n>,fab-ncp400-0/0/<n>) for a standalone NCP 0; the mixed-speed boxes carry adnos-port-namesgap, and management jacks adnos-management-namesgap. The fabric boxes (NCF-48CD, NCF-64E) wait for a document that names their hardware. - OcNOS listings for the IP Infusion HCL (#674). Every box
on the OcNOS 7.0.1 MR Hardware Compatibility List (July 2026) that the
library models - 42 of 44 - is listed under
ipinfusion/, with the edition that supports it (OcNOS SP or OcNOS DC) as its portfolio line. 14 UfiSpace boxes carry OcNOS port names: speed-class prefix (ge,xe,ce,cd) and one 0-based count across the panel, as IP Infusion's own S9510-30XC configuration shows and as the UfiSpace silkscreen already numbers them, witheth0for management. The rest carry anocnos-port-namesgap: Edgecore boxes do not all count the same way (the AS7316-26XB restarts per speed class), and no 800G prefix is documented. - The other halves of the AC connectors, for rack PDUs (#933). Two outlet faces:
std/c19-outlet@1(IEC 60320-3 sheet J, from SCHURTER 4710-5; its 3D well follows its R5 outline) andstd/nema-5-20r@1(the T-slot receptacle, from Qualtek 739W-X2/30). Two jumper ends, drawn from the cable end like the C13 and C19 ones:generic/c20-plug@1, which mates the newiec-c19interface, andgeneric/c14-plug@1, which matesiec-c13, the interfacestd/c13-outlet@1presents. Four input plug faces:generic/nema-l6-20p-plug@1,generic/nema-l5-20p-plug@1,generic/nema-5-20p-plug@1(Leviton catalog drawings) andgeneric/cs8365c-plug@1(Hubbell M-6590). - Registry entries for all eight parts, and the
iec-c19connector interface. - DCIM:
iec-60320-c19andnema-5-20rjoinOUTLET_TYPESandPART_OUTLET; the four input plugs map inPART_POWERtonema-l6-20p,nema-l5-20p,nema-5-20pandcs8365c. Every slug is in both NetBox and Nautobot. - The four monitored connectorized panels of the same family:
amphenol-ns/nrg300cb08-ctrl-c,nrg300cb08-ctrl-sc,nrg300cb08-sens-candnrg300cb08-sens-sc. Each is the CTRL or SENS front with the -C or -SC rear (sixteenamphenol-ns/output-p40@1outputs, busbar or stud feeds) andamphenol-ns/nrg-rear-block@1where the passive panel has its alarm card. Their DCIM exports are as the CTRL and SENS. No existing device or export changes. - The Amphenol Network Solutions nrgILS300CB08-SC
(
amphenol-ns/nrgils300cb08-sc): the nrgILS300CB08 with the -SC rear, vertical stud feeds and sixteenamphenol-ns/output-p40@1outputs that acceptamphenol-ns/p40-plug@1, with the nrgILS rear centre block. No figure draws this version; it is the ordering line's combination of two modelled halves, and says so. In the DCIM exports it has the nrgILS's two management interfaces, twodc-terminalpower ports and sixteen P40 power outlets. No existing device or export changes. - The Amphenol Network Solutions nrgILS300CB08 (
amphenol-ns/nrgils300cb08), the load-shedding member of the 300CB08 family: the nrg300CB08-CTRL front on a chassis 42.4 deeper, read off its own bottom view, with the plain stud-and-screw rear and a new centre block,amphenol-ns/nrg-ils-rear-block@1(nrgNET IN and OUT as RJ45s, a probe jack, three unnamed headers), which the DCIM exporter skips as not a DCIM port. In the DCIM exports it has two management interfaces,mgmtandlan(1000base-t), and twodc-terminalpower ports. No existing device or export changes. - The P40 output plug,
amphenol-ns/p40-plug@1(Amphenol PRM0400, 4 mm contacts), and the interface it mates,p40.amphenol-ns/output-p40@1presents it, so all sixteen outputs of the 300CB08-C, 300CB08-SC and the four nrg300CB08 connectorized panels are connector slots that accept the plug. The plug is drawn from the wire side with a stub per pole (BATT, RTN), sized bywire-odand coloured bywire-color; no panel seats one by default. - AurCore, a new vendor, with its ten AIS industrial DIN-rail switches (#744,
#745, #748). They are the first devices to state
chassis.mount: din-railandchassis.bevel: a fanless finned housing, octagonal in section, that clips onto a 35 mm rail or screws to a wall. Each has onebaseconfiguration and exports to NetBox and Nautobot withu_height: 0.- The large housing, 83.8 x 145 x 110:
aurcore/ais4001pandais4001(8 GbE and 4 SFP+),ais2003pandais2003(8 GbE and 4 RJ45/SFP combo ports, whose copper halves arecopper-9tocopper-12),ais2004pandais2004(8 GbE and 12 SFP). - The small housing, 72.1 x 110 x 93:
aurcore/ais2001pandais2001(4 GbE and 2 SFP),ais2002pandais2002(8 GbE and 2 SFP). Its console jack is on the top face, not the front. - A
pmodel is the PoE+ build: two lamps to a jack and a 48-57 V feed, where the plain model has one lamp and 12-55 V. - Fronts are measured from each model's own product photograph. Tops and backs are estimates from an angled render, and each manifest says so in its gaps.
- The large housing, 83.8 x 145 x 110:
- The shared parts the AIS switches need, all in
common/(the vendor has no component namespace of its own):din-clip-ts35@1(the TS35 rail clip),wall-plate-keyhole-2@1andwall-plate-keyhole-2-42@1(56 and 42 mm keyhole plates),dip-switch-2@1,ground-screw-washer@1, and the two pluggable headers,terminal-header-508-5f(power) andterminal-header-508-2(relay). The headers have since taken majors: pinterminal-header-508-5f@2andterminal-header-508-2@3. common/rj45-ganged-link@1, the ganged RJ45 cell with one lamp, for a jack that shows a single LINK/ACT window (#745). It joins the RJ45 family in lint and exports as1000base-t. Itslamp-rightskin is for a column turned the other way, which keeps the lamp at the top.- A routed cable's tight bends are a finding (
@portrayal/kit0.17.0, #973;docs/cable-lay-design.mdsection 3.4).routePathreturnsbends, each corner of the path with less room than the cable's own installed bend radius (ctx.bendOf(cable), else its media's), as{kind: 'tight-bend', cable, point, between, at, angle_deg, legs_mm, room_mm, need_mm, short_mm}, andbendFindings(rack, ctx, nameOf)gives them rack-wide with a sentence.cornersOfandSTRAIGHT_DEGmove torack/route-path.js(rack/bundles.jsstill exports both), andcornersOf(points, {share: 'need'})shares a leg between its two corners by what each turn uses of it, not by halves; the bundle check keeps the halves.detourinrack/solids.jstakesroom. A path point can beat: 'lead'. - The 1RU plug-in breaker (
amphenol-ns/breaker-1ru@1, 1.1.0) has astate:on,offortripped(#808). ON is up, toward the I of the printed I/O legend, as the product photograph shows;offandtrippedcarry the handle 5.8 down its slot, because the Airpax datasheet says a trip puts the handle at OFF. The face draws the toggle end-on and the handle is redrawn as that 8 by 8 end; the red-over-green mark beside it is redrawn as the printed legend it is. The eleven 300CB08-family panels draw their breakers ON as before and take a patch. @portrayal/kit0.8.0: the bend check for cable bundles (#922,docs/cable-bundles-design.mdsection 5.2). Withctx.bendOf(loadCableTypes(dist).bendOf, #919),bundleCheckand every bundle command's findings check the bundle at each corner of its trunk, and at each pathway whose guide states aradius, against the largest installed radius among the members present there, so one fibre makes a bundle as strict as fibre. A corner's room is worked out from its legs,min(a_in, a_out) / tan(theta / 2), and marked estimated; a pathway's stated radius is its room. Each miss is a warning, never a refusal, naming the place, the room, the member that sets the need and how far it falls short. A member with no radius is listed as unchecked, never passed.inspectof a bundle givesbend: {radius_mm, by, unchecked, points, violations}where it gavenull, andcornersOfandbendCheckare exported from@portrayal/kit/rack/bundles. Cables outside a bundle are not checked. Superseded by kit 0.17.0 in this section:routePathreports the tight bends of every routed cable.@portrayal/kit0.9.0: cable bundles in the exports (#923,docs/cable-bundles-design.mdsections 7 and 13).bundleExports(rack, ctx)in@portrayal/kit/rack/export-datagives one record per bundle (number, label, members, length, strap count, size, bend, warnings),bundleNotesone line per bundle with its warnings, andstrapBomRowsthe bill of materials' one hook-and-loop strap line, every bundle's straps summed. draw.io's notes say bundles are drawn there as separate cables.@portrayal/kit0.7.0: cable bundles in the rack kit (#921,docs/cable-bundles-design.md). A rack's optionalbundlesholds cables combed into one run along a stored trunk,{id, number, label, members: [{cable, a?, b?}], route, straps?}; membership lives on the bundle only.bundle.create,bundle.add,bundle.peel,bundle.updateandbundle.removemake and change them, each one undo step, with{error}refusals; with the routing context (ctx.route)bundle.createworks the trunk out from where its cables run together and refuses a fork, a loop, a detour or groups that share nothing by name.resolveRoutefollows a member's bundle and names itsbundle,joinandleave. A new module,@portrayal/kit/rack/bundles(with@portrayal/kit/rack/bundle-route), checks a bundle's size against the smaller of 2.5 in and each opening on its trunk (bundleCheck,bundleChecks,pathwaysOn; a duct running up a part and a duct beside the rack are estimated from their channel and depth), warning and never refusing, and places its straps every 12 in unless it says otherwise (straps).inspect,describeandselectCablesknow bundles;BUNDLE_GONEjoinsGONEandCABLE_GONE.parseDoc(input, {notes})repairs a file's bundles (an id another thing has, a member naming no cable, a cable in two bundles, a number used twice) and says so innotes, one sentence per repair naming its rack;editor.loadDoc(doc, {notes})returns them first in itsfindings.chassis.full-depth: falsestates that a rack device leaves the opposite face of its rack units free, and the DCIM export writes it asis_full_depth: false. A rack device that says nothing keeps thetrueit has always exported; this is stated rather than derived fromdepth, so no existing export changes. L125 refuses it on a device that is notrackmounted (#854).- Cable managers, pieces 2 to 4: brushes, pass-throughs, guides and lab
placement (
docs/cable-managers-design.mdsections 5 to 7). Abrushpanel-decor pattern withbristle: vertical | horizontalpaints itself as a solid field, needs no backing rect and is never an air aperture (data-kind="brush-field",data-bristle). On a sheet body a sunk decor now builds a plate at that depth with no walls, as a well does, which is how a brush is an opaque slab in 3D.passes:on a view declares where cables cross the face, each{id, at, size, shape: rect | obround, cover: open | brush}, compiled to invisibledata-class="pass"outlines in a--passesgroup. Lint L136: a pass lies inside its face and overlaps no component but a well that holds it whole. Lint L137: a pass covered by a brush has a brush drawn over it, and a brush over a pass belongs to one whose cover isbrush.guide: {kind: ring, aperture: {w, h}, run}on a component contract, andguides:(kind: duct, withfinger-pitchandfinger-gap) on a device view, compile todata-guide*attributes and an unpainteddata-class="guide"rect;components.jsoncarries a contract'sguide. Lint L138: a ring's opening fits inside its part, seen along its run, and a duct lies inside its view with a gap less than its pitch. Nothing consumes passes or guides yet, and the DCIM exports ignore both; the device lock fingerprints them only where they are declared. Superseded for the first half:rack.jsonlists each device's guides and passes, and@portrayal/kit/rack/routeroutes cables through them. At 0.2.0, 30 devices declare at least one: 18 state passes, 24 a duct guide, and 6 place a ring that carries a guide. The DCIM exports still ignore both.attrs.performance.cable-capacityandcable-capacity-basishold the vendor's one capacity figure per manager with its cable and fill basis (decision 9). A lab placement of arack-facedevice takesface(frontorrear) and is placedona host placement at itsunit(from 1 at the host's bottom unit), or at a rack unit byru. Labs have a schema,spec/schemas/lab.schema.json(its$idishttps://portrayal.dev/schemas/v1/lab.schema.json), checked by lint (L1) and by the build, and five rules: L139 (refs, ids andonresolve), L140 (face/on/unitonly on a rack-face part, placed byonorruand not both), L141 (the host is a rack device andunitis within it), L142 (everything fits the rack, no two rack devices share a unit, no two rack-face parts claim one unit on one face), all errors, and L143, a warning naming the host behind a rack-face part placed byru.labs_index.pywill not write a lab that fails L1 or L139-L142.roadm-ring-demopasses all of them. Everylabs.jsonplacement keeps its keys and gains its resolvedru,face,mount,hostandunit; new fields only,contractstays at 2, and a site that reads none of them still draws a rack-face part on its unit. Two devices:fs/cmh-4drb1u, the FS CMH-4DRB1U (#68690), a 1U sheet tray with four steel D-rings and a brush strip behind five windows, from the vendor's dimensioned front and side views, withfs/cmh-4drb1u-panel@1,-ring@1,-end@1and-flange@1; andfs/cmh-sfd1u, the FS CMH-SFD1U (#29038), a 1U ABS finger duct built hollow as a sheet body: the base plate as the well (fs/cmh-sfd1u-base@1), two rows of thirteen fingers standing in it (fs/cmh-sfd1u-finger@1,-finger-end@1) with twelve gaps a side at 34.1 mm, and the cover across their tips (fs/cmh-sfd1u-cover@1), which comes off to open the channel; the channel and its ends are open, and aductguide declares it. - Solid bodies and the
crosses-bodyfinding, step 2 of the cable lay (#949;docs/cable-lay-design.mdsection 1).rack.jsongainssolidsfor a sheet part and for a zero-U part that carries a lane, derived byrack_index.py(through the newrack_solids.py) from the compiled faces of its default configuration and never stated in a manifest: a sheet part is its plates (the floor of each well and each node that stands proud of it; never a ring, never drawn decor, and never anything inside a duct's footprint or mounted on a duct); a lane duct is what is left, its walls and back. Each box is{part, box: {x, y, z, w, h, d}, holes?: [{via, box, size}]}, x from the device's left as seen from its front, y up from its bottom, z back from its front; a hole is a declared pass-through. Any other device carries none and is its envelope; a device with cable space inside its envelope (the FHD enclosures) waits for step 6 of the note. The FHD-CMP5DR and the FS D-ring panels, finger ducts and vertical ducts gainsolids.formatstays 1. @portrayal/kit0.11.0: a new module,@portrayal/kit/rack/solids(solidsOf,legCrossings,detour,CLEAR), andbodyFindingsinrack/route.js.routePathreturnscrossingsanddetours;inspectof a cable returnsroute.crosses;describewith a route context adds a line "Findings: N cables cross a body.";cableScheduleRowstakes{bodies}and writes each finding's sentence into its cable's notes. A cable crosses a body only through a ring, a duct, or a pass-through whose smaller side fits its diameter (ctx.diameterOf, else its media's); a tie slot is never an opening, and a cable lying against a plate (its centre line a radius outside it, on either face) is not crossing it. The finding warns and never refuses.- Trays: a floor a cable lies on (#949,
docs/cable-lay-design.mdsection 2). A component contract declarestray:(itsfloorrectangles, theheightof the floor's top above the bottom of the envelope,lip,run, the tie slots cut in it asties, andslack,areaor aspool), so every placement of the part carries it; a device plan (its top view, and no other) declarestrays:by id. Each compiles to unpainteddata-class="tray"anddata-class="tie"rects, andrack.jsoncarries each device'straysin the frame of itssolids, with the openings of the rings standing on the floor. A route names a tray by its id, as it names a ring. L170 holds a floor inside its part or view, each tie slot on a floor, a tray's id to one pathway, its height to the depth of its well, and its ties to the slots the device draws on its bottom view. The schema's recorded shape is re-recorded: the component and device schemas now accepttrayandtrays. - A ring places its opening:
guidegainsdepth(along the run),sill(from the base it stands on to the lowest inside edge of the opening) andaperture.at(the opening's corner on the drawing). They compile todata-guide-depth,data-guide-sillanddata-guide-aperture-at. L138 holds each inside the part. - fs/fhd-cmp5dr-tray@1 1.1.0 states its tray: the strip and its two arms, 3.0 mm up the envelope, no lip, the sixteen slots as ties, slack as area. fs/d-ring-snap-in@1 1.2.0 states its opening: 6.8 mm along the tray, its sill 5.6 mm above the floor (read off the ring-profile view, where 2 mm was estimated before), its corner at 12.75, 5.8. fs/fhd-cmp5dr 1.1.0.
cable-types.jsonin the published build: named cable types (OM3, OM4, OM5, OS2 and its G.657.A1 and A2 cords, Cat 6 and Cat 6A U/UTP and F/UTP patch cords, passive DAC by gauge, AOC, and C13 and C19 power cords named by their cord), each with its media, a typical outside diameter and a minimum bend radius{installed, loaded}as a fixed figure or a multiple of the diameter, marked standard or convention, with its source. The source table isspec/schemas/cable-types.yaml. The bare type ids are the Rack Builder's cable media, so a cable's media names its type. The kit's new@portrayal/kit/rack/cable-typesresolves a type's installed radius in millimetres (radiusMm,installedRadiusMm,bendLookup) and loads the file (loadCableTypes). A new file, socontractstays 2 (#919).- Power outlets in the DCIM export, for a distribution panel's outputs
(#806). Two placement keys say what an outlet needs:
fed-bynames the placement whose power port the output hands on, andthroughnames the bay - the breaker or fuse position - the circuit runs through. A placement of a part indcim_export.PART_OUTLETexports as apower-outletsrow on the device type, named by its placement id, withpower_portset fromfed-by;throughis written as a sentence on the outlet's description and appended to the bay's (; protects output-a1), since Nautobot drops an outlet's description on import. Both targets read the same block. The ten Amphenol 300CB08 panels gain sixteen outlets each (dc-terminalon the 300CB08, the monitored nrg300CB08-CTRL and -SENS and the nrgILS300CB08;otherlabelledP40on the connectorized -C and -SC); nothing is renamed or removed. Statingfed-byorthroughis a minor device version, changing one a major. Lint L132 (fed-bynames a placement that exports a power port), L133 (throughnames a bay), L134 (every outlet statesfed-by: a warning, an error atverified) and L135 (no two outputs name one position: a warning). Design note:docs/power-outlets-design.md. optical.trunk, an optional component key (#246): the positions that are a single-faced module's common, network-side end, infront-order's item grammar. The DCIM projection puts them on rear ports as it puts a rear-face connector there - one per trunk part, named<PART>-1- so a module whose connectors are all on one face exports at last. Front port names keep the faceplate's count, so no published number changes meaning; components.json carries the key insideopticalas it carries the rest. The eight path-bearing Smartoptics PPMs state one, andppm-ad1-1510andppm-ad1-1625gain their glass from ds-ppm-r4.0's signal-flow figures: add and drop written as banded legs off the line port. A fibre-map row on a banded leg carries itsband.- New exports for the PPMs.
exports/fibre-maps/Smartoptics/, a fibre map for each of the eight; front and rear ports in the eight NetBox module types and the four DCM Nautobot types. Nautobot cannot put several front ports on one rear position, so the two OCU couplers' and two AD1 filters' Nautobot types state no ports and say the split is in the NetBox type and the fibre map. - A fibre adapter that exports nothing is named, not dropped
(#204). Device and module types record the ones with no
glass behind them in their comments - 117 on the three DCP chassis, two on
the DCP-F-A22, and the LC adapters of seven CommScope CH3000 modules - as
the decision #204 asked for: neither an interface nor a front/rear pair.
Only
commentschanges on those types.common/lc-duplex-adapterleaves NOT_A_DCIM_PORT. - Lint L129, L130 and L131, on components (#246):
optical.trunkis for a single-faced module and names nounusedposition by number (L129); every leg of a projected module runs between the front and the trunk (L130); and a module withoptical.pathshas a trunk, a rear face oroptical.trunk(L131, an error). L78 checks trunk entries name a connector and a position it has, and L79 allows a source to start several paths when all but one carry abandand no two carry the same one - an add/drop filter, not a hidden split. - The Dell PowerEdge R660 (
dell/r660,draft), a 16th-generation 1U two-socket server, 434.0 x 42.8 x 773.5 (#721):- Five fronts as variant views: ten 2.5 inch bays (
front), eight with a Smart Flow vent (front-sff8sf), no backplane (front-nobp), and sixteen or fourteen EDSFF E3.S (front-e3s16,front-e3s14). - A rear whose riser band takes riser configurations 0 to 9, and a top view of the interior into which seated supplies, risers, cards and front drives project. The bottom and sides are estimates.
- 42 orderable configurations, named
<front>-rc<n>-<risers>, and four examples. Its NetBox and Nautobot device types are namedPowerEdge R660 <configuration>. - The riser slots accept the cards the R740xd slots accept: the generic brackets and cards and the NVIDIA ConnectX adapters, and on the full-height risers 1P and 4P the UfiSpace N3100-4C.
- Five fronts as variant views: ten 2.5 inch bays (
- The
dell/parts the R660 needs, 71 component majors at 0.2.0, among them: the 60 mm AC supplies (dell/psu-700w-ac-60mm@1,-800w-,-1100w-,-1400w-); six OCP NIC 3.0 cards and a blank (dell/ocp3-*); the LOM card, the MIC card and the rear I/O board; the BOSS-N1 module, its M.2 carrier and blank; the E3.S carrier, blank and fillers; twelve 16G risers (dell/riser-1p-16gtoriser-4p-16g) and the cages they compose; the interior plan parts; and the 1U 16G bezel, drawn fitted. std/drive-e3s@1and thedrive-e3sstandard inspec/schemas/standards.yaml: the EDSFF E3.S drive, 76.0 x 7.5 x 112.75, which the E3.S bays accept besidedell/e3s-carrier@1(#721).- common/pan-screw-m5@1, an ISO 7045 M5 cross-recessed pan head, 9.5 across and 3.5 high, drawn where a document shows one (#971).
chassis.earsmay be an object as well as the stringbehind(#906):{behind?, h?, y?, positions: [{name, label?, at?, default?, racks?, part?: {kit, part}}]}, wherenameisflush,recessed,mid,rearorproudandatis millimetres from the faceplate front back to the ear plane.chassis.kitslists the rail kits a device takes:[{ref, supply: in-box|optional, variant?: reversed, depth?: {config, range}}]. Both are optional, for a rack device only (L125), and documented indocs/format-stability.md. No device states either yet. Superseded forchassis.ears: four devices state it at 0.2.0,eaton/pdumh20net,fs/fans1u2f,fs/fans1u4fandfs/uscmh-sfdabsb2u. No device lists a kit, and nokind: kitcontract is in the library.- Lint L160 to L163 check them: at most one default position; each listed kit
ref is a
kind: kit, listed once; a position's{kit, part}names a listed kit and one of its part ids; adepthoverride names a configuration of the kit, in that configuration's shape, with min below max. - A "Rack ears" toggle in the kit's Explorer (#909), off by default and shown
only for a device that gets a generic ear. It turns the generic L-bracket
ear on in 3D (
viewer.setEars) and in 2D, where the published face has no ears and the kit draws them as an overlay. The choice is remembered per viewer, not written into the page's location. Ears built into a face are part of the drawing and always shown. @portrayal/kit/ears2d(kit 0.9.0, the version that also carries the bundle exports of #923; kit 0.8.0 is the bend check of #922 alone):drawEarsandclearEarsdraw the generic ear over a published face asrender.py --with earsdraws it (the same shapes, ids and colours, and the viewBox grown to hold them), fromearPlan, the plan the 3D viewer builds. The overlay is not a part: it carries nodata-path, takes no pointer events, and an export of the live drawing carries it as picture. relief.jsEARgainsEDGE, the outline colour ears.py draws with.chassis.ears.color(optional, additive): the colour the generic ear is drawn in. configs.json publishes it inearswhere it is stated, and the plan from ears.py and relief.jsgenericEarscarries it ascolor. devicelock hashes it with the rest ofearsas chassis surface, so stating it is a patch.- The Eaton EVMA8365X, a Rack PDU G4 managed (0U, 41U, 1829 x 52 x 65 mm): a
CS8365C cord on a 208 V delta input (40 A, 50 A plug, 14.4 kW), 42 outlets (24
C13, 18 C39) in six sections A to F, a 20 A two-pole breaker per section with its
linesfrom the drawing's one-line diagram (A and D on L1-L2, B and E on L2-L3, C and F on L3-L1), the eNMC network module, and two mounting buttons 124.0 from the cord end at the 1555.8 pitch. Its capability ismetering-scope: outletandoutlet-switching: true, so its class ismanagedand every outlet declares the[on, off]states (#934, docs/pdu-model-design.md section 9.1). eaton/g4-outlet-led@1, the G4 outlet status lamp, placed beside each outlet withfor:; the device states itsongreen andoffred. A lamp with no state set draws unlit.eaton/g4-cord-cs8365c@1, the G4 fixed input cord with a CS8365C plug, exported as acs8365cpower port.eaton/evmi2130x, the Eaton Rack PDU G4 metered input EVMI2130X and the first rack PDU in the library: a 0U strip mountedrack-side, a fixed NEMA L21-30P cord, 42 outlets (24 C13, 18 Eaton C39) in six colour-coded sections, three 20 A two-pole breakers and a hot-swappable network module. Drawn standing, cord end down, from Eaton drawing 9001-22301.std/c13-outlet@1, the IEC C13 outlet face a PDU moulds (a well a C14 shroud enters, with the nose standing in it), and itsc13-outletentry in the standards registry.- Six Eaton parts:
eaton/c39-outlet@1(the proprietary C13/C19 combination outlet),eaton/g4-outlet-labels@1(section colour and outlet numbers are fields),eaton/g4-breaker-20a-2p@1,eaton/g4-mounting-button@1,eaton/g4-cord-l21-30p@1and the network moduleeaton/g4-enmc@1. eatonin the vendor registry.- The DCIM export writes AC power outlets:
iec-60320-c13andeaton-c39joinOUTLET_TYPES, both in NetBox and Nautobot, and the PDU's cord exports as anema-l21-30ppower port. No outlet statesfeed_leg: every outlet on the EVMI2130X is line to line. - A device's own
interfaces:rules now name its power outlets as they name its interfaces, so the EVMI2130X's outlets export as A1 to C42, as the unit prints them. An outlet no rule names keeps its placement id, so no other device's export changes. eaton/pdumh20net, the Eaton Tripp Lite series switched PDU PDUMH20NET: a 1U horizontal rack PDU with 16 NEMA 5-15/20R outlets, eight on the front and eight on the rear, named 1 to 16 as printed, eachfed-bythe fixed L5-20P input cord and each with a lamp bound to it byfor:. Classswitched-metered-input; every outlet declares[on, off]. The WEBCARDLX network card sits in a bay, the two-digit load meter on the front, and the ground screw and the factory DE-9 on the rear. The bolt-on brackets arechassis.earswith flush (default), recessed and rear positions. No drawing exists: every position is read off the two straight-on Eaton photographs, with the scale proved on the DE-9's standoffs and the outlet faces.- Three Eaton parts for it:
eaton/webcardlx@1(the network card module),eaton/tripplite-ammeter@1(the two-digit load meter) andeaton/tripplite-cord-l5-20p@1(the fixed input cord, exported as anema-l5-20ppower port). eaton/pdumv20hvnetlx, the Eaton Tripp Lite series switched PDU PDUMV20HVNETLX and the library's first switched rack PDU: a 0U strip mountedrack-side, a C20 inlet on the face (the detachable L6-20P cord is not drawn), 24 outlets (20 C13, 4 C19) in two load banks of twelve named 1 to 24 as printed, a lamp bound to each outlet withfor:, a two-digit load meter, the LX Platform interface (10/100 Ethernet, an RJ45 console, USB-A) and two toolless mounting buttons that publishmount-points1556 apart. Classswitched-metered-branch; every outlet declares[on, off]. Drawn standing, from the Tripp Lite submittal drawing 17-08-067. The two bank breakers are not placed: no held source shows where they are (abreaker-positionsgap).- Three Eaton parts for the Tripp Lite series:
eaton/tripplite-led@1(the round lamp window beside each outlet),eaton/tripplite-mounting-button@1(matespdu-button) andeaton/tripplite-load-meter@1(two seven-segment digits and the Select / Rotate button). - FS.com blanking panels: FHU-BPS-1U-10, FHU-BPS-2U and FHU-BPS-4U (screw-on
steel), FHU-BPSTL-1U-10, FHU-BPSTL-2U and FHU-BPSTL-4U (tool-less steel with
ABS clips, the new
fs/bpstl-clip@1), FHU-BPA-1U-10 (ABS, pegs and magnets) and FHU-BPAD-2U and FHU-BPAD-4U (ABS, wave-ribbed, snappable). Each is drawn as the whole plate, 482.6 mm (482 for the BPA), with its slots or clips. - FS.com rack fans: FANP3U3F (3U panel, three fans behind stamped guards, a
rocker switch, front-to-back airflow) and the FANS1U2F and FANS1U4F 1U fan
trays, each with the new
fs/fan-temp-controller@1(two-digit display, LOAD and SET lamps, four keys). All three take power through the newfs/fan-cord-5-15p@1, which exports as anema-5-15ppower port. - FS.com cantilever shelves FS-CFS-1U, IWEP1U350 and IWEP1U550 as sheet bodies:
a vented floor, side walls to their profile, a rear lip on the IWEP, and the
built-in ears drawn on the full rack-width face. Each states its usable
surface and static load in
attrs.physical. - FS.com DIN rail brackets DINRAIL2U and DINRAIL4U: two side brackets with
built-in ears, a rail panel and a 400 mm TS35 x 7.5 rail
(
fs/din-rail-ts35-400@1), with the rail's profile, length, height and setback range inattrs.physical. fs/cmh-sfd2u0.1.0, the FS CMH-SFD2U 2U single-sided ABS finger duct (#29039): the CMH-SFD1U fingers on an 86.5 mm base well with two 75 x 37.5 pass-through holes, and its own pullable cover. Hollow, not full depth, Cat6 capacity 124 at 100% fill. New partsfs/cmh-sfd2u-base@1andfs/cmh-sfd2u-cover@1.fs/cmh-dfd1u0.1.1, the FS CMH-DFD1U 1U dual-sided ABS finger duct (#29040), 174 mm deep: the fourfs/cmh-sfd1uparts on the front view and again on the rear, two channels and two covers that pull separately, the joined bases between them closed by sunk plates. Not full depth: it bolts to the front rails and at 174 mm does not reach the rear rails. Cat6 capacity 96 at 100% fill across both channels.fs/uscmh-sfdabs1u,fs/uscmh-sfdabs2uandfs/uscmh-sfdabsb1u0.1.0, the FS USCMH ABS finger ducts (#317015, #317017, #317023): nine fingers a row on a 53.9 mm pitch, a hinged cover that pulls, pass-through windows, and the ribbed base behind the ears drawn as a straight box. Depths are the drawings' 97.0, 107.0 and 162.83 mm; the product selector's 71 and 127 mm for the 2U and the B1U are the projection in front of the ears. FS states no weight or cable capacity for this line, and each device records both as vendor-silent gaps. New partsfs/uscmh-sfdabs1u-base@1,-cover@1,-finger@1,fs/uscmh-sfdabs2u-base@1,-cover@1,fs/uscmh-sfdabsb1u-base@1,-cover@1and-finger@1.- Four FS 1U D-ring cable managers, each a flat steel panel between the ear folds
with its rings standing out of it, built as a sheet body so that the rings are open
loops you can see between:
fs/cmh-5dr1u(five detachable polycarbonate rings,fs/cmh-5dr1u-ring@1),fs/uscmh-5dr1u(five polycarbonate frames,fs/uscmh-5dr1u-ring@1, under a cover,fs/uscmh-5dr1u-cover@1, that the explorer can pull, and four windows through the panel),fs/cmh-5dr1u-n(five steel rings,fs/cmh-5dr1u-n-ring@1) andfs/cmh-6dr1u(four of the same steel rings). Every ring carries aringguide. Each device states its cable capacity and is not full depth. The two end rings of the CMH-6DR1U stand outside the rack's width, beyond the ears, and are not drawn; the device records them. - Six FS ABS high-density finger ducts, built hollow from their datasheet drawings, the
only pictures FS publishes of them:
fs/cmh-uhd-sfdabs1u,fs/cmh-uhd-sfdabs2uandfs/cmh-uhd-sfdabs3u(175 mm deep),fs/cmh-hd-sfdabs3uandfs/cmh-hd-sfdabs4u(112 mm deep), each a back plate with pass-through windows, two walls of ten T-shaped fingers and a hinged cover the explorer can pull; andfs/cmh-bs-dfdabs2u, a 2U dual-sided duct with a channel, fingers and a pullable cover on each side of a shared spine. Each states its cable capacity,full-depth: falseand a vendor-silent weight. Where the drawing dimensions a cover taller than the rack unit, the device is that tall:fs/cmh-uhd-sfdabs1u0.1.0 is 52 mm high over its 44 mm ears andfs/cmh-bs-dfdabs2u0.1.0 is 93.5 mm over its 87 mm ears, the covers overhanging the units above and below;rustays 1 and 2. The HD and UHD lines share one finger part each,fs/cmh-hd-sfdabs-finger@1andfs/cmh-uhd-sfdabs-finger@1; the other new parts are per model. - The FS steel finger ducts, five horizontal cable managers built hollow like
fs/cmh-sfd1u: a sheet body whose backbone is the floor of a well, two rows of fingers standingin:it, and a cover that can be pulled.fs/cmh-sfds1u(1U, cover 51 mm high),fs/cmh-sfds2u(2U) andfs/cmh-bs-sfds1u(1U, steel channel with ABS fingers) are single-sided and statefull-depth: false.fs/cmh-dfds1u(1U, covers 57.8 mm high) andfs/cmh-dfds2u(2U) are dual-sided, with a channel and a cover facing the front and another facing the rear; they bolt to the front rails and, at 230.6 and 232 mm, do not reach the rear rails, so they too statefull-depth: false. Each brings its own base, finger and cover components (fs/<model>-base@1,-finger@1,-cover@1, andfs/cmh-bs-sfds1u-finger-end@1). Only CMH-BS-SFDS1U has a stated cable capacity; the other four carry avendor-silentgap for it. - A generic L-bracket rack ear, drawn from
chassis.ears(#909): a flange each side reaching from the body to the 482.6 mm rack face, with a slot over each rail hole, and a 30 mm leg back along the body,ears.htall andears.yup (the chassis's height, and 0, where they are absent), its flange on the default position'sat.render.py --with earsdraws it on all six faces asear-leftandear-right; the kit's viewer builds it in 3D withcreateViewer(el, {ears: true})orviewer.setEars(true), from relief.jsgenericEars, and a GLB taken then carries it. A device that is not arackdevice, statesears: behind, has a front as wide as the rack face or still placescommon/rack-ear@1gets none in 2D. The default build draws no ears, so no published face, export or device lock changes. - Lint L164 warns when
chassis.earsy + his above the chassis, and L165 when two ear positions have the samenameandlabel. common/ground-screw-m4@1(ISO 7045 M4 pan head, 8.0 across, 3.1 high) andcommon/ground-stud-pair-5-8-m4@1, two of them on 5/8 in. (15.875) centres presentingstud-pair-5-8, so ageneric/two-hole-lug-5-8@1seats across an M4 grounding pair (#830).common/ground-screw@1: the stud, washer and cap ofcommon/ground-lug@1without its earth symbol, presentingterminal-studat the same height, for the second screw of an unsized two-screw landing whose chassis prints one symbol (#830).nokia/sr-1-dc-stud@1andnokia/sr-1-dc-pole@1: one 10-32 stud of the 7750 SR-1 DC terminal block, and a pole of two of them on 5/8 in. centres presentingstud-pair-5-8(#828).nokia/sr-1-dc-terminal-block@1(1.1.0) composes four poles,a-neg,a-rtn,b-negandb-rtn, so a two-hole lug seats across each pole of the SR-1 DC (0.1.3) and a ring lug on each stud. The 45-degree lug the guide names is not built; the straight one stands in.- A two-hole lug across a pair of studs (#828). Three connector interfaces,
stud-pair-5-8,stud-pair-3-4andstud-pair-1, each spanning twoterminal-studseats at the pitch in its name (15.875, 19.05, 25.4), and a lug for each,generic/two-hole-lug-5-8@1,-3-4@1and-1@1, drawn across with the wire leaving along the pair. Pair hosts compose two studs at the pitch and present the pair at their midpoint, at the top of the studs:juniper/mx-ground-stud-pair-5-8@1,juniper/mx-ground-stud-pair-3-4@1,common/ground-stud-pair-5-8-m6@1,-5-8-1-4@1,-3-4-1-4@1and-1-1-4@1. A pair and its two studs are one level or the other (L115); each stud still takes the ring lug alone. docs/connectors-dc-terminal-design.md section 13.7. - Sized ground screws (#830):
common/ground-screw-m6@1(ISO 7045 pan head) andcommon/ground-screw-1-4@1(ASME B18.6.3 pan head), used only inside the pair hosts.common/ground-lug@1stays the nominal, unsized ground screw. - HPE, a new vendor, with the ProLiant DL160 Gen10 (
hpe/dl160-gen10), a 1U two-socket server (#759). It has two fronts as variant views, four LFF bays (front) and eight SFF bays with a media bay (front-sff8), over one rear, and a top view of the interior. Its seven configurations arebase, the orderablesff8, and five examples. The NetBox and Nautobot device types are named for the two chassis option numbers,878972-B21and878973-B21. - The
hpe/component namespace, 42 parts at 0.2.0 (#759, #761, #778, #780):- drive carriers and blanks for both fronts, the 500 W and 800 W Flex Slot supplies and their blank, the fan, heatsink, system board and access panel;
- the primary and secondary risers,
hpe/riser-primary-dl160@1andhpe/riser-secondary-dl160@1, whose PCIe slots are bays behind a standard bracket window, so the cards the library already has seat in them; - the FlexibleLOM riser
hpe/riser-flom-dl160@1, a second occupant of the primary riser bay, whoseflombay acceptshpe/flom-blank@1and twelve FlexibleLOM adapters, each named for its option number (hpe/flom-817749-b21@1is the 640FLR-SFP28); hpe/riser-blank-primary-dl160@1, the plate fitted where no primary riser is ordered, seated by thelff4-no-riserexample;- three Media Module adapters, the serial port option and their blanks. The adapters were renamed to their option numbers before any release, as the HPE entry under Removed records (#760).
common/rj45-eth-pinside@1: a lamped RJ45 whose two lamps are in the side walls at the pin end, away from the latch notch (#781). It iscommon/rj45-eth@1with the lamps at the other end. It joins the RJ45 family in lint and exports as1000base-tunless the placement states a speed. Three HPE adapters use it, the 562FLR-T, 535FLR-T and 533FLR-T.kind: kit, a third kind of component contract, for a rail, bracket or slide kit (#905). A kit has noclass, nosizeand no skin, and admits onlyformat,kind,name,version,description,provenance,unplaced,superseded-byand the kit keys:motion,travel,install,parts({ref, id, count}),configurations({id, racks, parts, depth, preset, tolerance, rail-depth},depthone[min, max]or one per hole type) andaccessories({kind: cma|srb, ref, rail-depth, sides}). A component or module still requiresclassandsizeand takes none of them. No kit is in the library yet.- Lint L155 to L159 check a kit: each part ref resolves to a component that is
not a kit and part ids are distinct; a configuration names only the kit's
own part ids and has an id of its own; every depth range has min below max;
travelonly withmotion: sliding; each accessory ref resolves to a component that is not a kit. library/dist/kits.json: every kit as its contract states it, written bycomponents_index.pyon every build ({"kits": []}while there is none). A kit is never an entry ofcomponents.json, and the component catalogue lists kits in a table of their own, outside its component count. The keys are documented indocs/format-stability.md.- The kit device picker offers the NOS vendors and the boxes each lists
(#711).
createDevicePickerin@portrayal/kit/devseltakes two optional inputs,listings(the buildlistings.json) andlisting(the entry to start on). Choosing a listing loads the drawing of the hardware it lists and keeps the listing as the selection. Nothing an existing caller uses changes shape:onchange(name)still receives the device name, with{listing}as a second argument, andpicker.valueis still the device name, beside the newpicker.listing.pickerEntries(devices, listings)is exported, and gives the entries the picker shows. The explorer writes?listing=<ns>/<id>beside?device=, so a reload lands on the same entry. @portrayal/kit/nosnames, a new export: what a listing says its NOS calls each port (#719).listingNames(listing)andnosNameFor(listing, path)give the names,expandName(pattern, n)expands one pattern, andbreakoutNote(breakout, n)words a breakout. It is the grammar of the DCIM export, ported, and a test holds the two to identical names over every listing in the build. With a listing chosen, the explorer inspector shows the NOS name of a selected port. Only the top-level ports of a device are looked up, and a port the listing does not name is never guessed: the inspector names the listing gap that explains it.- The kit reads a device from its npm package (#691).
createShellandcreateViewertakedistas a function from a path in the build to its URL, or as a string, which still means a build directory, so an existing caller is unchanged.@portrayal/kit/distexports the three that make one:flatDist(base), a build directory;distResolver(dist, fallback), which accepts either form;await packageDist({at, index}), the published packages. A device file comes from that device package, a component skin from its components package, and every other file from@portrayal/index. Each is read at the exact versionpackages.jsonnames, andlatestis resolved to an exact index version first, so a page never mixes two releases.at(name, version)picks the server and defaults toJSDELIVR. The explorer reads the packages with?dist=packages(a locallibrary/packages/) and?dist=cdn, with&index=<version>to pin one. Its default is the build directory, as before. The per-namespace components packages of the npm entry in this section are whatpackageDistreads at 0.2.0.
rackDiagramin@portrayal/kit/drawiotakes three optional keys (#724). A group may carry its ownfaces, so a page draws only the faces it names and a rack builder can make one page per face. A mounted device may carry its ownid: cell ids are slugged from it and not from the name, so two devices of one model are two cells. A rack may carry its ownnumDisp, anddescendprints U1 at the bottom. Without the three keys the output is what it was.- The 3D viewer reports a lost WebGL context (#746). A viewer emits
contextlostwhen the browser takes the context away andcontextrestoredwhen the scene is back, with the rebuild error ornull, andviewer.contextLostsays which state it is in. <device>.configs.jsoncarrieschassis.kits: each rail kit the device lists, resolved inline in the order listed - the device'ssupply,variantanddepthoverride, and the kit'sversion,description,motion,travel,install,configurations(with the override applied),partsandaccessories, each part and accessory with itsversion,class,sizeandbody(#907). These are the refs devicelock'scomposedfollows fromchassis.kits(#906), andrender.py --if-stalenow rebuilds a device when a kit it lists, or a kit's part or accessory, changes. No device lists a kit yet.- The DCIM exports say a device's ear positions and rail kits in the comments, beside the overhang line, since neither NetBox nor Nautobot has a field for either (#907).
- Every lint rule says why it exists: what it prevents, and for whom (#952).
docs/lint-rules.mdgains a why column and a severity column, saying whether a finding warns, fails, or warns until a device claimsmaturity: verified. lint-rules.jsonin the dist: the rule table as data for the site's rule page, written bylint.py --list-rules --jsonfrom the same table as the page. Each rule carries its code, scope, rule, why, fix, a severity token (error,warning,at-verified,mixedormixed-at-verified), andfails,warnsandfails-at-verified(#952). It ships in@portrayal/index.- Lint L172 (error): whatever is named for a logo is a reserved place and
paints nothing (#964). A contract element, a skin node or a device region
whose id has the word
logoin it islogo-zone(orlogo-zone-<n>); the skin node is an emptyrectwithfill="none"and no stroke; the region statesatandsize; and no decor, cutout, silkscreen mark, bay or placement of a device carries the word. The library is clean under it and nothing was added to the lint baseline. The rule reads names only: a box standing for a mark under another name is not caught. - A JSON Schema for the marked-up drawing document,
spec/schemas/marks.schema.json, so a client that sends one (an MCP tool, a script) can be told what to send.normalise()inkit/marks.jsis tested against it: whatever it returns is a valid document. juniper/mx2000-lc-adapter@1, the MX2000-LC-ADAPTER (ADC, 150 W). It seats an MX240-form MPC turned 90 in its one bay,mpc, as the MX960 seats it. Its module type exports asMX2000-LC-ADAPTER.yaml.- In NetBox an MPC installed under the adapter names its components
fpcN/mpc/.... - Nautobot is not given the adapter's
mpcbay, because the same MPCs also seat directly in the MX240, MX480 and MX960. Superseded by the Nautobot entry under Fixed (#917): Nautobot has the bay at 0.2.0, with a blank position.
- In NetBox an MPC installed under the adapter names its components
- A configuration can turn a seated occupant: an
occupants:mapping takesturn:, in degrees, relative to the seat, one of the turns its host allows. An interface inspec/schemas/connectors.yamllists the turns it allows (terminal-stud: 0, 90, 180 and 270, so a ring lug turns freely on a ground stud), and a component's presented connection point may narrow them withturns:(common/terminal-screw-34@1and-38@1allow 0 alone: the barriers fix the pole). An interface that names none allows 0, so no other seat changes (#829). - Where a configuration states no turn, the build chooses one for a seat that turns: the wire goes down, toward the nearer side edge of the face, the other side or up, the first direction in which the whole lug crosses no part, bay or other seat; running past the edge of the face is allowed and a printed legend is avoided where it can be. Across the library's 155 ring-lug seats on 63 devices that is 103 down, 24 left, 22 right and 6 up, none across a part, and the ring lug no longer lies across LAN1 on the Supermicro SYS-111E-FWTR and SYS-111E-FDWTR, the ESD jack on the Juniper MX150, a fan bay on the Edgecore DCS500 or the second stud of a pair. A two-hole lug on a stud pair (#828) turns 0 or 180 only, and its 51 seats on 25 devices lead 45 down, 4 left, 1 right and 1 up; two of them, on the MX150 and the MX480, cross a part either way and are recorded. No library configuration seats a lug, so no drawing changes (#829).
<device>.configs.jsonpublishesturnson every slot entry (the angles an occupant may take on top ofrotate, null where there is no choice) andseat-turns,{view: {slot key: {ref: turn}}}, the turn the build seats a part at where its configuration states none; a seated occupant on a seat that turns carriesdata-seat-turn.components.jsoncages carryturnstoo (#829).- The explorer offers a turn for a seated lug in the inspector, seats it the
same way in 2D, in the faces it holds and in 3D, and writes the reader's
turns to the share link in a parameter of its own,
turn=<key>~<deg>, so a link written before it keeps its swaps.kit/swap.jsgainsseatTurn,seatRotate,encodeTurns,decodeTurns,acceptTurns,builtTurnsandturnOverrides;occupantAt,occupantTransform,seatOccupant,applyOccupantOverrides,applyFaceOverrides,seatFace,seatViewsandviewsToRewritetake the turns as a further, optional argument (#829). - Lint L146: an occupant's
turnis one its host allows. L147: a connection point'sturnsis a subset of the turns its part's interface allows, and only the presented point states one (#829). combineon an optical path, an optional component key (#246): several sources landing on one destination, the opposite of a split, written in place offromas a list of{at}entries with onetoendpoint. Each source says how it joins - abandfor a wavelength combine (the add side of a filter) or aratiofor a power combine (a coupler run backwards) - and the two do not mix. Two plain paths into one position are still an error; only a declared combine may share one. The DCIM projection writes one fibre-map row per source, carrying itsbandorratio, exactly as it writes one per destination of a split, so a combine onto a trunk position and banded legs off it export the same rows. A contract written before this key reads as it did. A published build carries the shape: an entry ofoptical.pathsinlibrary/dist/components.jsonmay now holdcombineand nofrom, so a consumer that readsfromon every path must allow for it.- Lint L171, on components: a
combinehas one destination and no path-levelband, names each source once, and its sources either all carry aratiosumming to 100 or carry bands, no two the same, with at most one source carrying what the bands leave. L78, L80 and L130 read a combine's sources as they read any other endpoint, and L79 allows several sources on one destination only inside a declared combine. optical.legsin the tools: the reader for the three path shapes.optical.endpointsis built on it, so the fibre map, the fibre-ends index and every lint rule that walks a path read the shapes in one place.@portrayal/kit0.10.0: an outlet's state is shown on its lamp (#934;docs/pdu-model-design.mdsection 3.2). A state set on the path of an element that declares states - a switched PDU outlet - is applied to every lampfor:binds to it as well: by a marks document (marks.jsapply), by the Explorer's chips, and in the 3D scene (relief.jsapplyNodeStates,viewer3d.jssetStates), through one rule in@portrayal/kit/states:boundLamps(svg)(path -> the bound lamps) andexpandStates(map, bindings). A seated plug or silkscreen naming the outlet declares no states and is left alone, and a port declares none of its own, so no drawing already in the library changes.relief.jsgainsnoteLampBindings,clearLampBindings,lampBindingsandexpandedNodeStates.- A drawing marks an element a lamp is bound to with
data-lamped="true", and the base stylesheet dims a power outlet that isoffand has no lamp (opacity 0.55); one with a lamp is never dimmed. No device in the library has a switched outlet yet. Superseded: three do at 0.2.0,eaton/evma8365x,eaton/pdumh20netandeaton/pdumv20hvnetlx. - A rack PDU states its capability as two facts,
attrs.management.metering-scope(none,input,branch,outlet) andoutlet-switching, and the class is derived from them and published aspdu-classin<device>.configs.jsonanddevices.json:basic,switched,metered-input,switched-metered-input,metered-branch,switched-metered-branch,metered-outletormanaged(#934, docs/pdu-model-design.md). Lint L166 states the two together and ties the outlet[on, off]states tooutlet-switching. - Structured input keys in
attrs.power:input-cord,input-phase,input-wiring,input-voltage-v,input-current-a,plug-rating-aandcapacity-kw;input-plugis now thePART_POWERslug of the input (L167), and a PDU states its voltage ininput-acrather thaninput-voltage(L168 warns on both). The DCIM export writes the rating on the input power port's description and in the comments, beside the derived class. - A placement key
lines(L1,L2,L3,N) on a breaker, or on an outlet with no breaker, andthroughmay now name a fixed breaker placement as well as a bay (L133 widened, L135 reads bays only, L169 new). An outlet's export description names its breaker and lines, andfeed_legis written only for a line-to-neutral outlet on a three-phase wye input. pdu-button, the rack PDU mounting interface, in the connectors registry, andconfigs[].mount-pointsin<device>.configs.json: each mount point a configuration draws,{mates, at}, derived from the button placements.- A lab's rack-side
sidetakes the kit's attachment points:left-front,left-rear,right-frontandright-rearbesideleftandright. L154 checks overlap per point and refuses a side that mixesleftwith a four-post name;labs.jsonpublishes the point as written. A rack-facesidestaysleftorright(L153). spec/tools/portrayal/preflight.py, one command a builder runs before asking for review (#924). Against the merge base with--base(defaultorigin/main), working tree and untracked files included, it prints PASS or FAIL per check with the command that fixes it, and--jsonfor an agent: the DCIM exports regenerated from the tree and compared withlibrary/exports(no build: the exporter's dist is derived from the sources), added skip reasons againstspec/allowed-skips.txt, private strings in added lines, the changelog fragment,devicelock(also against the base lock for a device the diff re-locked), lint on the touched devices and every device that seats a touched component plus the library-wide rules a--devicerun skips, with no warning beyond the baseline, andnpm testwith the kit behaviour tests that name a changed module whenkit/changed. No build and no suite run.- Preflight has an eighth check,
prose, and it only warns (#114). It reads eachdevice.yamlandcontract.yamlthe diff changes and reports a sentence of more than 25 words that the merge base does not have, in adescription(device, configuration or component) or a string underattrs. That is the prose a DCIM export carries. Text the base already holds is never reported, words quoted from a vendor are not counted, and gap notes andprovenanceare not read. A WARN leaves the exit status and theokfield of--jsonunchanged; a check'sstatusin--jsoncan now beWARNas well asPASSorFAIL.CONTRIBUTING.mdstates the rule: new and changed prose follows Simplified Technical English, and existing text is not rewritten. @portrayal/kit0.4.0:@portrayal/kit/rack/*has commands and questions an agent can use without reading the code (docs/rack-agent-commands-design.md).fitseats, empties or restores one bay or cage;fieldsets one setting of one seated part;cable.updatetakesaandbto move an end and keep the cable.cable.routerefuses a waypoint the rack lacks and judges only the new ones.inspectreads one device's bays, cages and part settings, or one cable's ends, route, routed length, slack and loose ends (unchecked: truewhen the ends could not be read);selectCablesturns "the cables on this device" or "every loose cable" into ids (saying when some ends could not be checked), and refuses apurposeormediathat is not a name;describetakes a window (section,offset,limit, at mostMAX_WINDOW, 50, lines a section) and refuses one it cannot read;catalogfilters bykind.loadSlots(dist, refs)inrack/catalog.jsloads the parts lists thateditor.apply(cmds, {ctx})andeditor.preview(cmds, {ctx})check against, for that call only.rack.jsongives every device akind, an advisory word for what it is (switch,router,patch panel,cable manager,server,pdu, ...) whose words may be refined without a format change, anddevices.jsoncarries each device'sprofile, whichkindis read from. Both are additive:rack.jsonstaysformat1 anddevices.jsonstayscontract: 2.library/dist/rack.json: the rack catalogue, written byrack_index.pyafter the compiled faces exist. Each device carries its rack units, size, airflow, default configuration and configurations, and, only when it has them, itsmount,shell, stated cablecapacity, and theguidesandpassesids a cable route can pass through on each view.formatis 1; the keys are documented indocs/format-stability.md.@portrayal/kit0.3.0 carries the Rack Builder's rules as@portrayal/kit/rack/<module>: the rack file, fit rules, cable managers, cables, routes, the export and DCIM rules, the catalogue loader (loadCatalog(dist), which readsrack.jsonthroughflatDistorpackageDist), and the command core: every edit as a named, validated command (commands.js), undo and redo (history.js), a headless editor with change events (editor.js) and queries that read a rack (queries.js).kit/README.mdhas a "Racks" section with an example thatspec/tests/js/rack-readme-example.mjsruns.spec/schemas/rack.schema.json, published athttps://portrayal.dev/schemas/v1/rack.schema.json: the schema of a rack file (format: "portrayal-rack",version2). It is the Rack Builder's file format, not a manifest, so it does not carry format 1. Superseded: a 0.2.0 rack file isversion3 and its schema is at/schemas/v2/(the rack file entry under Changed).chassis.overhang: {left, right}states how far arackdevice's real parts reach beyond its rack face, in millimetres (#865). Such a device draws its front at the rack face with its ears, and a part beyond it is an ordinary placement at negative x or past the view's width. L150 refuses a placement, bay or cutout outside its face that the side's figure does not cover (optional placements and decor are not checked); L151 warns when no part reaches a stated figure.<device>.configs.jsoncarries it aschassis.overhang, and the DCIM exports say it in the comments, since neither schema has a field for it. To devicelock it is a statement, likemount: the parts that reach past the face carry their own geometry.chassis.ears: behindstates that a rack device's ear folds are behind its body, so a 482.6 mm front is the part and L43 stands down (#865).<device>.configs.jsoncarries the statement underchassis.ears, in the object form #907 publishes; devicelock files it as surface.fs/uscmh-sfdabsb2u0.1.0, the FS USCMH-SFDABSB2U 2U ABS finger duct, the width of the rack in front of its rails, from the FS Horizontal Single Sided Manager datasheet, with its partsfs/uscmh-sfdabsb2u-base@1,-finger@1,-end-finger@1and-cover@1(#865).fs/cmh-6dr1u-end-ring@1andfs/cmh-6dr1u-ear@1, the CMH-6DR1U's end ring, with a verticalringguide, and its ear (#865).- A ring says what of its loop is solid (#968,
docs/cable-lay-design.mdsection 3.3):guidegainswall(each leg beside the opening),height(the top of the loop over its base) andslit([from, to], the gap in the far leg of an open loop). They compile todata-guide-wall,data-guide-heightanddata-guide-slit, and L138 holds each inside the part. A sheet part'ssolidsin rack.json now carry each such ring's legs, bar, seat and hook asring/<id>/<part>. The schema's recorded shape and L138's rule text are re-recorded. - fs/d-ring-snap-in@1 1.3.0 states them: legs 5.8, the loop 41 high, the slit 28.6 to 30.8 mm over the tray. fs/fhd-cmp5dr 1.1.1.
- The snap-in rocker (
common/rocker-switch@1, 1.1.0) has astate,offoron(#808), and is the first part whose position SHOWS rather than moves. It is drawn as the see-saw it is: one surface tipped about its centre, a node for each position, rising toward the I end foroff(drawn, as before) and toward the O end foron. In 3D each is a slopedprofile, 4.9 at the raised end and 2.2 at the low end, both read off the GL-12xB GLB. The ReadyLinks GL-12xB-240D and the Catalyst 4948E (through its AC supply) draw as before and take a patch.common/power-switch-slide@1is left without positions: no source says which end of its travel is ON or how far the slider moves. - Seven parts that draw their own rocker take the same see-saw (#808): the
Juniper JNP10K-PWR-AC2 and MX80 AC supplies and the Telco Systems TM-7124S
AC supply (
state), the Casa C40G AC inlet panel (switch-1toswitch-4), the Casa PEM's rocker breakers (breaker-1tobreaker-4), and the Nokia SR-7 and SR-12 PEM-3 (breaker,power-switch), each a contract minor with estimated heights. The devices that seat them draw as before and take a patch. Rockers whose art marks no ON end, and the SR-1 DC block whose lamp rides on its rocker, are left as drawn; the design note says why for each. - Lint L144 (warning): members of one group that one configuration draws on
one face hold one
rel-poseach (#414). Variant views of a face and bays thatonly-inscopes to different builds are alternatives and may share a position; a position reused on another face is not reported. Thirteen devices carry a clash and are in the lint baseline: the six Juniper MX chassis whosegroundinggroup puts an ESD jack at position 0 beside the first earthing stud or plate (mx80, mx150, mx204, mx240, mx304, mx480),dell/r740xdfurniture,ufispace/s8901-54xclane lamps, and the port lamps ofedgecore/agr110,agr130,agr560,csr310andecs4120-28fv2-i. Each cure renumbers or regroups placements, a major device version, and is left for a decision. - Lint L145 (warning): a group is not named
ports, which names no port family (#414).dell/r660,dell/r740xdandmaiaedge/port-extenderare in the baseline; renaming a group is a major device version. - A position field may list
drawn-by-absence: the options drawn by showing none of its SHOW nodes. Lint L148 now asks every other option of a field with SHOW nodes to show at least one node (#874). - A position is a field (#808, docs/switch-positions-design.md). A
choicefield may now MOVE a skin node (data-move-fromand adata-movetable ofoption: dx dy [deg]) or SHOW one (data-show-fromand the options listed indata-show). The build applies both, the kit'spaintFieldsapplies the same two rules at runtime andunpaintFieldsputs them back, and in 3D a change to such a field rebuilds the scene, because a moved node stands somewhere else. An option the field does not declare fails the build. A placement may say what each position means inpositions:, carried into the drawing asdata-positions. Lint L148 holds a position's table to its field's options and L149 keeps a moved node on its part; L73 counts both attributes as wiring.common/dip-switch-2@1(1.1.0) is the first user:sw-1andsw-2,offoron, drawnoffas before, so the ten AurCore devices that place it draw as they did and take a patch. - The 300CB08 family's alarm DIPs (
amphenol-ns/alarm-dip-8@1, 1.1.0) are the second user:sw-1tosw-8,upordown, drawn up as before. The eleven panels that place them say inpositions:what each switch does (the alarm for breaker position A1 to B8; on the nrgILS, whether a circuit is held on out of software control), and theirpopulatedandwith-fusesconfigurations set the switch of every fitted position down, as the installation guide requires. Each panel takes a patch. - Two more FS vertical cable managers, both
rack-side.fs/cmv-dfd45u5w, the FS CMV-DFD45U5W (#63030), a 45U dual-sided ABS finger duct with hinged PVC covers on both faces, 2108 x 138.8 x 302 (the drawing; the table and the dimensioned render say 310, recorded as asources-disagreegap), built hollow as two channels back to back across a 25.6 mm spine. Its back and cover views are the CMV-SFD45U5W rasters byte for byte and its side view lands on the single-sided figures within half a millimetre, so every part is reused on both faces:fs/cmv-sfd45u5w-base@1,-wall@1,-finger@1,-clip@1and-cover@1. The middle is closed by plates sunk inside the side, top and bottom faces, as onfs/cmh-dfd1u. Capacity 5490 Cat6 (datasheet); the 16.80 kg product page weight is stated and flagged as suspicious, 3.5 times the single-sided 4.75 kg.fs/cmv-sfd42u9w, the FS CMV-SFD42U9W (#188944), a 42U single-sided finger duct, 1866.9 x 88.9 x 152.6 in two 21U sections: a folded steel channel open at six rectangular windows (fs/cmv-sfd42u9w-base@1), two finger walls (-wall@1), 84 moulded T fingers at one rack unit (-finger@1) and a pullable cover a section (-cover@1), measured on the 600 dpi page render of its low-resolution drawing. The material (SPCC on the product page, ABS in the datasheet) and the cover (none in the specification, drawn and rendered) aresources-disagreegaps; the drawing and renders are modelled. No capacity is published for it. - The FS steel vertical finger ducts, CMV-SFDS45U5W (#220089) and
CMV-DFDS45U5W (#220091), two
rack-side45U parts, 2000.25 (45 x 44.45) tall and 169 wide over their steel covers, from the four views of the FS steel vertical datasheet (portal id 6868). Both are built hollow as sheet bodies: a steel back plate (on the dual, a 2.4 spine) as a well open at its seven windows, two steel returns, 44 T-shaped fingers a row at one rack unit with the top unit empty, and two pullable steel covers a working face (976.45 or 976.95 upper, 1021.4 lower), each with six hinge clips, under aductguide run down the 141.52 channel.fs/cmv-sfds45u5wis 152.63 deep with its seven back-plate openings declared as pass-throughs;fs/cmv-dfds45u5wis 307.66 deep with a channel, fingers and covers on its front and rear faces. New partsfs/cmv-sfds45u5w-base@1,-wall@1,-cover-upper@1,-cover-lower@1, the same four forcmv-dfds45u5w, andfs/cmv-fds45u5w-finger@1, the finger both ducts share. The covers reserve a logo zone. Neither part carries a cable capacity: no FS document states one (acable-capacitygap). - Vertical cable managers, steps 1 and 2:
rack-sidemounting andsideplacements (docs/vertical-cable-managers-design.md).chassis.mount: rack-sideis a part that attaches to the side of a rack's upright and runs vertically beside the rack, outside the rails. It statesru, the rack units it runs beside (L125 warns without it, andfull-depth,overhangandearsstay rack-only), and its DCIM export writesu_height: 0andis_full_depth: falsewith the comment line "Mounts on the side of a rack's upright, beside the rack; occupies no rack unit." Lint L152 (warning): a rack-side part's front is taller than it is wide, because it is drawn as it stands. A lab placement takesside: left | right. A rack-side part states it and is placed byru, its bottom unit (default 1), on aface(defaultfront); it takes noonorunit. A rack-face part narrower than the 450 mm rack opening may state it too, and then claims its rack unit per face AND side, so a bracket on each rail shares a unit; any other rack-face part claims both sides (L142). Lint L153 (error):sideonly on those two, and a rack-side part has one. Lint L154 (error): a rack-side part fits the rack's height, and two on one side of the rack do not overlap. Everylabs.jsonplacement gainsside(left,rightornull); a new field only, andcontractstays at 2. Two devices:fs/cmv-sfd45u5w, the FS CMV-SFD45U5W (#63033), a 45U single-sided ABS finger duct with hinged PVC covers, 2108 x 138.8 x 165.1 (cover included; body 125.4), built hollow as a sheet body from the datasheet's back, side and cover views - the back plate as a well open at eight oval pass-throughs (fs/cmv-sfd45u5w-base@1), two finger walls (-wall@1), 92 fingers at one rack unit (-finger@1), 24 cover clips (-clip@1) and a pullable cover per 22.5U section (-cover@1), with aductguide run down its height; andfs/cmv-5u3w, the FS CMV-5U3W (#64186), a 5Urack-facefinger bracket 26 wide, 222 high and 84 deep on the rail face, from the datasheet's side and top views (fs/cmv-5u3w-base@1,-fingers@1). @portrayal/kit0.6.0: parts beside the rack and parts on one rail are the rack kit's (#926;docs/vertical-cable-managers-design.mdsection 8). A zero-U part (mount: rack-side, a vertical cable manager or a zero-U PDU) is an entry ofrack.zeroU,{id, ref, cfg, label, at, offsetMm, between?}, placed, moved and removed byzerou.place,zerou.updateandzerou.remove, and fitted by the rack units it states, not its drawn height. A narrow rack-face part (under the 450 mm opening) goes on one rail withside.placeand changes rail, or goes across both, withside.set. A new module,@portrayal/kit/rack/zero-u, says where each part stands;describeandinspectlist them, and the export data says where each stands (zeroUNotes,zeroUImportItems,rackNotes(rack, {zeroU: false, chassisOf})). A cable lane runs through a duct beside its upright (laneXAt), andfillandcapacityOvercount the cables through it.rack.schema.jsondescribes thezeroUentry andsideon an item, and no longer callszeroUreserved. Both keys are optional and unconstrained, so every file that validated still does; the rack file staysversion2 (docs/format-stability.md). Superseded: it stayed 2 for this change only. Bundles made itversion3 (the rack file entry under Changed).
- Schemas: the device schema types ten keys that took any scalar at 0.1.0.
BREAKING for a manifest outside this library that already used one of
these names with another spelling of the value: the schema refuses it now.
Under
attrs.power:input-plug(a lowercase slug, asnema-l21-30p),input-cord(fixedordetachable),input-phase(singleorthree),input-wiring(wyeordelta), andinput-voltage-v,input-current-a,plug-rating-aandcapacity-kw(each a number above 0). Underattrs.management:metering-scope(none,input,branchoroutlet) andoutlet-switching(a boolean). These are the keys the two rack PDU entries under Added introduce. At 0.1.0attrs.powerandattrs.managementtook any key with a string, number or boolean value, and they still do for every other key. No key was removed from any schema. All 1,226 manifests of the 0.1.0 library (170 devices, 1,027 component majors and 29 listings) validate under the 0.1.0 schemas and under these. The component and listing schemas refuse nothing they accepted.formatstays 1, and each schema keeps its$idunder/schemas/v1/. relief.profileandprofile-ynow move withoutwhen their part standsin:a well or is seated in a lifted bay, so the heights stay heights above what the part stands on. The schema used to say a profile was not shifted byin:; no part in the library before the FS FHD-CMP5DR met that case, so nothing already built changes.chassis.rualso means the rack units arack-facepart's ears span, not only units occupied; L125 asks arack-facedevice forru, and L43 (ears are not drawn) stands down for it.- The Nautobot export stops on a front port it cannot state truly, instead
of writing it: a one-fibre front port whose
rear_positionis missing or outside its rear port's positions, and a front port collapsed to one position that is not the whole of its rear connector, fibre for fibre. No export in the library changes (#771). - A device's
ponflavour types only a port: an SC receptacle or a pluggable cage. A lamp or label in a group that statesponno longer exports as a second PON interface. No export in the library changes (#772). - Lint L39 counts a lamp as punched when the holes over it together cover
more than half of it, not only when one hole does, and a lamp whose part
declares several windows also when the holes cover more than half of those
windows. A lamp seen through several windows could not be covered before,
however honestly they were punched.
expand.pystill punches a lamp automatically only when its part declares one opening.edgecore/ais800-32d(1.1.0) punches its 128 lane windows as round cutouts (led-port-N-lane-K) and drops the L39 waiver it carried for want of this (#395). spec/schemas/standards.yaml: thesc-duplex-adapterpitch floor is 12.71, the narrowest of the five gaps it was measured from, not 13.0, their mean. L81 now accepts an evenly spaced SC adapter panel at 12.71 or wider, where it used to refuse anything under 13.0.fs/fhd-1mtp12-sc-os2-a@3(3.0.2) no longer undercuts the floor and drops thepitch-notethat said it did; the seven FS FHD enclosures that seat it take a patch (#245).- BREAKING for DCIM data already imported. Telco Systems is listed as
BATM/Telco Systems, the name the vendor asks to be listed under. Themanufacturerof its fourteen devices changes, and with it every one of its NetBox and Nautobot exports: themanufacturerfield of fourteen device types and thirteen module types, each device type'sslug(telco-systems-tm-8104is nowbatm-telco-systems-tm-8104), and the directory they are written under,Telco Systems/toBATM-Telco Systems/(a slash in a manufacturer is written as a hyphen in the directory, as it is in a model's file name). A DCIM that imported the old files holds a manufacturer namedTelco Systems: rename it there before importing again, or the new files create a second manufacturer beside it. The namespacetelco-systems, every component and device ref, every port name and every drawing is unchanged, and so is the@portrayal/telco-systems-*package name of each device.spec/schemas/vendors.yamlkeepsTelco SystemsandBATM Networksas aliases. - The npm packages: the component skins ship one package per namespace,
@portrayal/components-<namespace>, andpackages.jsonin@portrayal/indexmaps each namespace to its package and version undercomponents. One package for every skin was the largest in the scope, grew with every component and moved whole with any one skin.packageDistin@portrayal/kit/distreads the new map, and@portrayal/kitis 0.2.0 for it: 0.1.0 reads the old single entry and cannot load an index published from here on.@portrayal/components0.1.0, published before the split, is not updated again (#526). - The Nautobot exports are no longer a copy of the NetBox ones in two places,
because Nautobot could not import 37 of them. Front ports under
library/exports/nautobot/now carryrear_portandrear_port_position(read from the fibre map) in place ofpositions, which is the shape Nautobot's FrontPortTemplate requires; and a device that occupies a half rack unit states the next whole number, with the true height incomments, because Nautobot storesu_heightas an integer. That is the 35 FS FHD cassettes and panels, the Juniper MX104 (3.5U, written as 4) and the Telco Systems TM-7124S (1.5U, written as 2). The four MPO-to-MPO adapter panels state each front and rear connector as one position there, since Nautobot binds a front port to a single rear position; the fibre map keeps every fibre. None of the 37 could be imported into Nautobot before, so no imported data changes. The NetBox exports and the fibre maps are unchanged. - A 3D export leaves the marks out (roc-ops/portrayal-site#46):
exportData()anddownload()hide every mark halo for the export, as they always hid the selection halo, and restore them after. A GLB or USDZ is the model; the marks stay on screen. - BREAKING for DCIM data already imported. The DCIM exports no longer
call every device without
rua 1U full-depth rack device. A box that is not racked exportsu_height: 0, not full depth, with its mounting in the comments (ReadyLinks GL-8XEP, Halny HLX-TGV), and the Dell R740xd exports at its real 2U. A DCIM that imported these types holds the old height until they are re-imported (#734). toDrawio()'sportsis what a line can be drawn to (#730): every port and every empty bay. A bay holding a card is a container that takes no line, and counting it overstated a modular chassis by its seated cards.connectable(ports)indrawio.jsgives the same count.toGraffle()is unchanged - every port and bay there is a magnetised shape - and itsportsnow says so.- BREAKING for DCIM data already imported. The Edgecore DCS510's AC builds
export as
9716-32D-O-AC-F-EUand9716-32D-O-AC-B-EU, not9716-32D-O-A C-F-UKand9716-32D-O-A C-B-UK, under Edgecore and its Arrcus, IP Infusion and SONiC listings. Two UK part numbers carried a stray space, which sorted them first; with it removed the EU part number names the type, as for a build whose every part number has a cord. A DCIM that imported the old types keeps them under the old model; re-import under the new one (#720). - The DriveNets names leave the UfiSpace hardware (#674).
Twelve UfiSpace boxes carried their NCP name as an
oemalias (#518) - the S9700-53DX'sNCP-40Cand so on. DriveNets' own listing now carries it (drivenets/<box>/listing.yaml,model:), filed under DriveNets and found by search and the picker, so the alias is removed and each box takes a patch bump.aliasesindevices.jsonand<device>.configs.jsondrops those names, and the UfiSpace DCIM types lose "Also sold or listed as: NCP-...". The S9600-102XC losesNCP-96X6C-Stoo: the DNOS CLI reference accepts only the S9601-102XC for that model. The fabric boxes (S9705-48DNCF-48CD, S9725-64ENCF-64E) keep theirs until they are listed. amphenol-ns/output-p40@1is 1.1.0: it gains its interface and mate point, and its drawing does not change. The six panels that place it take a patch; their DCIM exports change in the drawing version line only.cisco/asr-9902andcisco/asr-9903(1.0.4) record the Fixed-Port Routers installation guide's dimensioned top views, Figures 18 and 19: 439.5 mm for the ASR 9902 and 439.9 mm for the ASR 9903, which settles the stencil-versus- data-sheet question in favour of the stencil (#374). The ASR 9902'stwo-chassis-one-body-outlinegap is closed; the ASR 9903 carries achassis-width-sources-disagreegap naming the rescale (0.99108 on every x) and the five parts it reaches, still to do.- ASR 9000 route switch processors seat where a Cisco document names the
chassis (#262).
cisco/asr-90063.1.0 takes the A9K-RSP-4G, RSP-8G, both RSP440s and both RSP5s in slots 0 and 1;cisco/asr-90101.1.0 adds the RSP-8G, RSP440s and RSP5s to slots 4 and 5;cisco/asr-99043.1.0 adds the RSP440s and RSP5s to slots 1 and 2; andcisco/asr-9906andcisco/asr-99101.1.0 add the RSP5s to their outer RSP slots. Sources: RSP datasheet c78-500699 Table 3, RSP440 datasheet c78-674143 Table 3, the IOS XR 64-Bit datasheet c78-737841 System requirements and the RSP5 datasheet c78-741128. Each chassis names its sources underprovenance.rsp-chassis-support. Nothing is renamed or removed; the DCIM exports change in their bay descriptions only. - The 1-port and 2-port 100GE MPAs seat in the modular line cards
(#262).
cisco/a9k-mod400-se@2and-tr@2(2.1.0) take both in both bays, from the Ethernet Line Card Installation Guide list for the 400G card.cisco/a9k-mod200-se@2and-tr@2(2.1.0) take the 1-port in both bays and the 2-port in bay 0 only, which is what the guide states and is how the one-2-port-per-card limit of data sheet c78-735809 holds. - The
unplaced:sentence on the twelve ASR 9000 parts still seated by nothing now names what blocks each one: no compatibility statement in the corpus (four line cards), a double-height SPA, the ASR 9906 rear that has no fabric bays, power trays with no tray-level bay, and two parts with no document or part number. - The two-position RELAY header on the ten AurCore AIS switches (
aurcore/ais2001,ais2001p,ais2002,ais2002p,ais2003,ais2003p,ais2004,ais2004p,ais4001,ais4001p) iscommon/terminal-header-508-2@2, placed turned 90 at the same centre. Its two contacts now run parallel to the five of the power header, with the keyed side toward the RELAY legend, as the vendor's video and product images show. A seatedgeneric/terminal-508-2-plug@1turns with it and overhangs the RELAY legend, as the five-position plug overhangs POWER.@2is 12.16 wide, the Phoenix Contact MSTBA 2,5/ 2-G-5,08 (1757242) width, with the contacts and thematepoint (6.08, 6.05) 1.0 further in. Each of the ten devices takes a major, 0.1.x to 1.0.0. The header is still drawn 12.1 high, which counts the solder pin; #873 asks whether it should be the installed 8.6 (#804). Superseded: #873 was answered in this release.@2is removed, and the ten switches seatcommon/terminal-header-508-2@3, drawn 8.6 high, at 2.0.0 (the entry on the two headers in this section). kit/rackno longer speaks as portrayal.dev's page (#895). A rack file newer than the kit is refused with "this reader supports up to version N" (no "Reload to get the newer page"); a system command sent without originsystemis refused as "a system command, sent only by the caller"; theCOMMANDSdescriptions say "set by the caller" and "sent by the caller".kitReadmeandtitleLinesname their maker assource(defaultPortrayal),kitReadmepoints a blank site or role atsettingsAt(default: the rack'sdcim.siteanddcim.role), and the Nautobot script's address is named only when the caller passesscriptUrl: there is no portrayal.dev default. A host that wants its own sentences passes them; the Rack Builder passessource: 'the Portrayal Rack Builder', its ownsettingsAtand its script URL to keep its README as it was.- The rule and fix text of L18, L31, L45, L50 and L132 (
--list-rules,docs/lint-rules.md,lint-rules.json) now say what each rule checks (#959). L18 asks a port on a family cage to state its media; L31 checks a distance a side or top region label states; L45 is cleared by drawing the face or by a gap whosescopenames it, not by anempty:sentence (whose 40-character floor the schema holds); L50 is about printing off the part or covered by something drawn after it, not font size; L132 names both of its branches. What the rules raise is unchanged. - The modelling guide and the pitfalls page state each lesson as a rule with
its check, and no longer need the reader to know the device that taught it
(#71). Measured tables keep their sources. A few cases stay as examples,
each after its rule and marked Illustration. Both pages say how a new
lesson is written, and the
portrayal-model-deviceskill lists the gates in order. docs/modelling-a-device.md, Stage 2, says again that the pitch of a ganged block is read fromspec/schemas/standards.yamlbefore it is measured off an image: an explicitpitchwith itspitch-kind(targetto use,floorto clear), the notes of an entry with nopitchkey, androw-pitchfor stacked rows. Device provenance already cited the guide for that rule.- A routed path leaves every turn room for the cable's bend radius
(
@portrayal/kit0.17.0, #973). On the reference rack of #949, 86 corners of the sixteen paths had less room than OM4's 25 mm, and almost none was a real bend. A free span is now sampled evenly along its arc, a landing is laid as the tangent points of its two bends, and no hang is laid that leaves a corner short of the radius; an approach point stands the bend radius from its ring's band where the route turns there, and a cable from behind it is led square to it through a lead point; each move to a detour's plane is two bend radii long; and a cable whose first turn needs more leg than its plug gives runs on straight out of it. None of the 86 is left. What the kit's rules find no room for is still routed, and reported. ONE-WAY: routed lengths change on saved racks. On the reference rack every cord is 10.9 to 179.2 mm longer and seven of the sixteen move from 0.5 m to 1 m (c1 to c3 and c5 to c8; c4 stays 0.5 m, the lower leaf's eight stay 1 m). On one sample of 60 generated racks (1,803 cables of mixed media,spec/tests/js/bend-room-sample.mjs) a length moves by 113 mm shorter to 297 mm longer, median 14 mm longer, 93 stock sizes up and 34 down, and the corners short of their radius fall from 22,910 to 959, each a bend the kit's rules found no room for. A cable written the other way round does not always lay the same: 38 of those 1,803 measure differently from the other end (19 before), and 9 report a different number of bends. No cable runs in front of a zero-U part's outward face that did not before. A saved rack's routed lengths and stock sizes are re-measured the next time a page measures them; an entered length is never touched. - The cable schedule has a
bundlecolumn straight afterroute, solength_source,statusandnotesmove one place right, and its notes carry a line per bundle. NetBox's cables file names a member's bundle first in its description ("Bundle 2. uplink. Length measured along its route."), and its over-limit note now speaks of the whole description. Nautobot's cables file is unchanged; its notes list each bundle's cables. - The rack file is
version3, a one-way change. Migration from 2 is the identity, so every version-2 file opens as it was, but a page saves every document it opens as version 3, and a page or kit from before 0.7.0 refuses a version-3 file rather than opening it and losing its bundles.rack.schema.jsondescribes version 3 and is published athttps://portrayal.dev/schemas/v2/rack.schema.json; the/v1/schema, which describes version 2, stays as published (docs/format-stability.md). This is the net result for 0.2.0: a rack file this release writes isversion3, and the schema that describes it is the one at/schemas/v2/. The two entries under Added that sayversion2 and/schemas/v1/describe the file before bundles. No rack file existed at 0.1.0. - Routed lengths change for a bundled cable: it is measured along its bundle's trunk, not its own route, between where it joins and leaves.
cable.remove, andremovewithcables: 'remove', take a cable out of its bundle in the same step and say so. A new cable's id, and a repaired one, is past every id a bundle still names, and an item id a trunk or peel point names is not handed to a new device.cable.routechecks waypoints againstctx.route.guidesOfwhen given, and a flatctx.guidesOfotherwise.describe's refusal of an unknown section namesbundles.fs/cmh-4drb1u1.0.1 andfs/cmh-sfd1u0.1.1 statefull-depth: false; both exportis_full_depth: false(#854).- A lab is validated (
docs/cable-managers-design.mdsection 6):labs_index.pyused to pass anylab.yamlthrough. The lab schema is strict on the top level and on placements (id,ref,cfg,label,ru,face,on,unit,turned), so a lab carrying a key it does not know now fails the build. A labrefis a device's barename. fs/d-ring-snap-in@11.1.0 declares its ring guide, a 32.0 x 29.5 mm opening run along the tray.fs/fhd-cmp5dr1.0.1 for that, and for stating its capacity of 30 ascable-capacityrather than in its description; its drawings gain only the guide attributes, and its DCIM exports change in their description and version only.- Lint L127 reads a
chassis.thicknessthat is not a number as a finding rather than raising. - Lint L44 counts a view's declared pass-throughs as openings in the part
that holds them, so a brush seen through a well's windows is not called
buried;
fs/cmh-4drb1uneeds no waiver. - Routed lengths change wherever a straight leg of a route would cross a
solid body:
routePathadds detour points there (over the near edge, a tray's front edge first; else round the end; else by a side lane; a detour that meets a second body goes round it too), which count in the measured length and are never stored. Most of the change is a cable from a port on a device's far panel, which now goes round its own device to the lane: on a two-post rack most rear routes, on a four-post few. A saved rack's routed lengths and stock sizes are re-measured the next time a page measures them; an entered length is never touched. A sheet part read from an olderrack.json, withoutsolids, is open, as every sheet part was before. - A zero-U part that stands in the gutter and carries no lane (a zero-U
PDU) moves the cable lane beside its upright outboard of it, at the units it
spans (
laneXAt): the lane runs in a gutter as wide as the usual one just outside the PDU, so a cable runs beside it and not through it, and a port leg to that lane goes round the PDU on its back, the side facing into the rack, never over its outlet face. Measured on one sample 42U rack (five switches and an FHD panel with an FHD-CMP5DR, four front and four rear ports each, every pair of ports, 780 routes) with a 52 x 65 mm zero-U PDU added: on a four-post with the PDU on a rear upright, 264 routes grew by 13 to 164 mm (median 63); on a two-post, 349 routes changed by -13 to +421 mm (median +202). Those figures are the PDU's own share, the same rack with and without it. - Cables rest (
@portrayal/kit0.14.0, #949,docs/cable-lay-design.mdsection 3). A ring on a tray holds a cable on its sill, its radius above the opening's lowest inside edge as mounted, at the side nearer the rail; a route through a tray lays the cable on the floor at its radius, or, where the page pins it (ctx.trayFaceOf) and the tray has tie slots, strapped under the plate, sagging between two straps no lower than the strap line; every other free span hangs by the 3D drawing's catenary scaled by theDRAPEof its family (fibre and AOC 1, twisted pair 0.5, DAC and power 0.35) and no tighter than its installed bend radius allows, and lands on any surface it would pass below.routePathgains pointsat: 'tray'andat: 'rest'and a list ofrests, whichinspectgives asroute.rests;solids.jsgainstraysOf. ONE-WAY: routed lengths change on saved racks. On the reference rack of #949 the upper leaf's cords grow 34 to 42 mm and the lower leaf's 125 to 144 mm (they now go round the tray's front edge to reach a ring on its sill), and thirteen of sixteen measure past the 0.5 m stock break where seven did; a free span to a gutter, or an unrouted jumper, grows by its hang. A saved rack's routed lengths and stock sizes are re-measured the next time a page measures them; an entered length is never touched. - The
cable.routerefusal names trays among what a device offers ("has no ring, duct, pass-through or tray called ..."). - Rule 7 of the modelling guide is narrowed: cable management that is
part of the product (a lacer and its rings, a tray, a spool, a bend-radius
bracket) is declared, and drawn where it is a part, with the tie slots cut
in a plate declared as
ties; accessories added in the field (loose ties, straps, retainer bails) stay undrawn. - The CXP, CFP, CFP2 and CFP4 cages are now the panel opening each standard
prints, as
std/sfp@1andstd/qsfp28@1are: the box is the opening,dthe bezel to the connector,relief.sizethe interior behind it, with the one 1.0 collar (#802).std/cxp@2is SFF-8642 Rev 3.3's 23.50 x 12.10 cut-out, 28.96 deep, with the 21.60 x 10.20 snout opening behind it;std/cfp@2the CFP MSA Mechanical Layout's 82.8 x 14.8 opening, about 126 deep (derived from a scaled figure);std/cfp2@2the CFP2 Baseline Drawing's 14.30-high opening at the 41.50 module width, about 87.5 deep;std/cfp4@2the CFP4 Baseline Drawing's 11.30-high opening at the 22.10 faceplate width, about 67.9 deep. Thecxp,cfp,cfp2andcfp4entries inspec/schemas/standards.yamlcarry the same figures and acavity; the CXP pitch floor is SFF-8642's printed 27.00 (was 30.0, an estimate) and the CFP2 floor the 42.50 faceplate (was 45.0, which the drawing's two modules per 86.35 opening contradicted). Every card that composes one (fourteen Juniper MICs and MPCs, five Nokia MDAs and NT cards, the Edgecore AMX-3200 sled) composes the second major, each port kept on its centre; the seventeen devices that seat those cards take a patch. A seated generic CXP, CFP, CFP2 or CFP4 optic sits where it did. casa/ground-strap@2composescommon/esd-jack@1for its 4 mm wrist-strap jack instead of drawing its own circle, so the C100G's ESD point is the same part the Cisco and Juniper chassis place (#413). The skin keeps the marked plate and the earth symbol; the 1.x circle and its misnamedbolt-holeelement are gone.casa/c100g1.0.0 seats it, front and rear.- A pull request records its change in a new file under
changelog.d/instead of editingCHANGELOG.md, which every pull request used to edit at the same lines. Each file holds entries under### Added,### Changed,### Removedor### Fixed;spec/tools/portrayal/changelog.pychecks them (a test runs it) and folds them into## Unreleasedwhen a version is cut. Until then the unreleased record is that section followed by the fragments, andchangelog.py --showprints the two together. library/components/CATALOGUE.mdis no longer committed../build.sh, and so./publish.sh, writes it at the same path, which is now gitignored, andpython3 spec/tools/portrayal/components_catalogue.py --library library --out library/components/CATALOGUE.mdwrites it without a build. Its component total and its per-part device counts moved with nearly every pull request, so a committed copy conflicted as often as the changelog did. The test that compared the committed page with the generator now checks the generator: that it runs and that its page has a row for every component major.- BREAKING for DCIM data already imported. Nautobot module types now
carry their own module bays, and a module seated only in such a nested bay
names its ports by the chain of bays above it. Nautobot copies a bay's
position as written and renders no bay name, so its bays are written plain
(
mic0atmic0), and the parent goes into the port names of what seats there:{module.parent}/{module}/port-1, which Nautobot renders tofpc3/mic0/port-1, the name NetBox gives the same port. 47 Nautobot module types gain 95 bays; the Fibrain XCU10's drawer now seats its four adapter holders, so its 48 fibre ports are reachable in Nautobot as in NetBox. A bay accepting a model that is also seated directly in a chassis bay (the A9K MPAs, the 7750 MDA-e family, the MX MIC-3D family, Dell's E3.S carrier; 35 models in all) is withheld, because that model's ports must keep{module}/x; 30 bays on 15 carriers, each named in the type's comments, wait for position templating upstream (nautobot/nautobot#5823). The renames are 934 component templates in 125 Nautobot module types, and every one of those types was offered no bay by any earlier Nautobot export, so no data imported through these exports holds the old names. Two caveats. A module ALREADY INSTALLED from an earlier import keeps the names it was created with, and re-importing its type does not update the templates. And a renamed type installed by hand directly in a device bay, against itsAccepts:list, renders with the token left in: Nautobot's render_name_template leaves a token deeper than the bay chain as written, so its ports read{module.parent}/slot1/x. NetBox exports and fibre maps do not change (#765, #834). dell/r660took five majors between its first merge and 0.2.0, none of them in a release. Each is listed for a consumer of main or of the npm packages:- 1.0.0: riser 3 starts at x 270.6, where the cage of riser 2 ends, and slot 3 is back at 268.5 (#743). Before that, low-profile slots were re-handed (slot 1 turned over, slots 2 and 3 tip-left) and every riser gained its 3D boxes, as patches (#726, #729).
- 2.0.0: the Gen5 riser print, riser configuration 9 and the redrawn E3.S blank, with the six removals listed under Removed (#749).
- 3.0.0: the rears not yet drawn.
dell/riser-blank-full-16g@1and five<front>-rc0-noneconfigurations for no risers,dell/rear-io-board-dlc-16g@1for liquid cooling, and examples without a LOM card and with the MIC (#750). - 4.0.0: riser 2S, the liquid-cooling module
dell/dlc-module-1u-16g@1and the PCH shroud in the top view. The heatsinks areonly-inevery configuration but the liquid-cooled example (#751). - 5.0.0: risers 2Q, 1P and 4P project into the top view, as estimates
(
size-confidence: estimated), and the gap that names them is renamedrisers-2q-1p-4p-from-above-estimated(#753).
dell/r740xdtakes three majors, 24.0.1 to 27.0.0. No placement, bay or port id changes in any of them, and each major is one change:- 25.0.0 adds the example configuration
sff24-rc4-1a2a3a-connectx-100g: the NVIDIA ConnectX-6 Dx MCX623106A in riser 2,nvidia/mcx623106-fh@1in slot 4 andnvidia/mcx623106-lp@1in slot 6 (#702). It joins sixonly-inlists, which the lock counts as a placement change. The device has 43 configurations. - 26.0.0 seats
common/drive-carrier-25@2andcommon/drive-blank-25@2in every 2.5 inch bay, in place of the@1of each (#721). The bays keep their size and ids. - 27.0.0 states
chassis.ru: 2(#741). The DCIM device types export 2U where they exported 1U, as the height entry in this section says.
- 25.0.0 adds the example configuration
- From 1.0, a retired component major is deprecated with the
superseded-by:key the schema already has, naming the ref that replaces it, not with a newdeprecated:marker asspec/DESIGN.mdsection 9 anddocs/format-stability.mdsaid. Nothing implemented the marker, so no manifest changes (#448). - FS DINRAIL2U and DINRAIL4U 1.0.0: the rail panel meets its side
brackets (#971). The datasheet's 400 mm is the rail; the panel is the
width between the brackets' inner faces, so it no longer stands about
10 mm clear of each bracket in 2D and 3D. fs/dinrail2u-panel@2 (421.2 wide)
and fs/dinrail4u-panel@2 (419.7) replace the @1 majors (see Removed).
The joint is drawn as the side views show it: the brackets' edges are
lowered between their ends, the panel's tabs lie on them, its flange shows
through the slots and window, and two M5 screws a side stand over the
slots, whole heads on the bracket's outer face, at the default setback (a
new
screwsgroup, four placements). common/drive-carrier-25@2andcommon/drive-blank-25@2are the 2.5 inch carrier at its own face, 15.3 x 73.0 (#721).@1drew 17.868 x 79.4, which is the bay pitch and seam extent of the Dell R740xd and not the carrier. Four Dell drawings of the part agree on the new size. The art is the@1art rescaled onto that face, not redrawn, and the element ids are unchanged (lamp-activity,lamp-status,featureson the carrier).dell/r740xd26.0.0 keeps its measured 17.868 x 79.4 bays and seats@2centred in them;dell/r660seats the same carrier lying flat.- A
kind: kitplaced in a view, accepted or defaulted by a bay (L5), composed as a part or seated in a component's bay (L10) is refused at lint instead of failing at render. A kit'ssuperseded-bynames a kit, and a component's names a component (L101). L43 stands down forears: {behind: true}as forears: behind. - devicelock files
chassis.kitsas chassis surface besideears, so stating either is a patch. A listed kit, its parts and its accessories join the device'scomposeddigest, so a kit edited in place asks each device that lists it for a patch. L89 counts a kit a device lists as reached, with its parts, andlint --devicelints the kits a device lists. - The component catalogue and
composed-byincomponents.jsonno longer count a kit as composing its parts or accessories. - The generic rack ear is silver (
#c8cacc, ears.pySILVER, relief.jsEAR.SILVER) unless the device states otherwise, inrender.py --with ears, the 3D viewer and the 2D overlay alike; it was drawn incommon/rack-ear@1's near-black, which relief.jsEAR.FILLstill names. Nothing published moves: no published face draws the ear. - A DCIM outlet description names the fixed breaker it runs
throughas the unit prints it,Through breaker A, lines L1-L2, not by its placement id: the breaker placement'sattrs.label, else itsattrs.section(the G4 tile letter), else the id (decided 2026-10-09). The EVMI2130X re-exports with its outlet descriptions changed and takes a patch, 0.2.1. common/ground-screw-m6@11.0.1: its description no longer says it is never placed alone - the EVMI2130X places one as its M6 bonding screw. The four devices that compose it take a patch.std/nema-5-20r@11.0.1: itsunplaced:sentence is gone, since the PDUMH20NET now seats sixteen of them. No other device composes it.std/c19-outlet@11.0.1: itsunplaced:sentence is gone, since the PDUMV20HVNETLX now seats four of them. No other device composes it.- Four Edgecore devices now record the AS number as
modeland the catalogue name as akind: marketingalias, as the rest of the line does (#916):edgecore/dcs500isAS7816-64X(aliasDCS500),edgecore/dcs510isAS9716-32D(aliasDCS510),edgecore/cor550isAS7926-40XKFB(aliasCOR550) andedgecore/cor580isAS9926-24D(aliasCOR580). Each data sheet's ordering table names the base model by the AS number. Device slugs are unchanged. No DCIM export is renamed: device types are named by SKU, and those of these four boxes and of the Arrcus, DriveNets, IP Infusion and SONiC listings of them keep their file names andmodel; their comments now list the catalogue name under "Also sold or listed as". The AIS800 line keepsAIS800-*as its model: its current data sheets and quick starts print no AS number, andAS9817-64Ois recorded as a superseded name. - The end allowance is per media, sourced, with a temporary dressing
allowance beside it (
@portrayal/kit0.16.0, #962;docs/cable-lay-design.mdsection 1.6). A routed length was the path plus 0.15 m an end, a figure with no source. The sourced part is now a table,END_ALLOWANCE_BY_MEDIA, of what is physically there and not in the path: at each end, the part of the plug inside the port and half the maker's short tolerance. It is 13.1 mm for LC fibre (generic/lc-plug@2; FS fibre cords are +x/-0), 34.5 for copper and a cable with no media (9.5 of generic/rj45-plug@1, and half of the 1 per cent a Brand-Rex Cat6A cord may be short at 5 m), 25 for a DAC (half the FS SFP+ DAC's +/-5 cm; its length is measured between the heads) and 52.4 for an AOC (generic/qsfp-cable@1's head in the cage; L-com's AOC is +x/-0). The LC and RJ45 plug depths rest on estimates, which section 1.6 lists. Service loops and dressing slack belong in explicit tray slack (#949 step 4), which is not built yet, so until it is the kit adds a dressing allowance of 0.1 m an end on top, for every media: temporary, by decision, with no maker's source, and not exported.endAllowance(cable)gives the two together (113.1, 134.5, 125 and 152.4 mm an end) androutePathreturns it as the path'sallowance, whichpathLengthadds (a path without one takes the copper figure); both, withEND_ALLOWANCE_BY_MEDIA, replaceEND_ALLOWANCE_M. A routed length is 73.8 mm shorter for LC fibre, 31 for copper and 50 for a DAC, and 4.8 mm longer for an AOC. On the reference rack of #949 seven of the sixteen cords move from 1 m to 0.5 m; on a 3,120-cable generated sample 221 move down a stock size and one moves up. A saved rack's routed lengths and stock sizes are re-measured the next time a page measures them; an entered length is never touched. BREAKING for a page that importsEND_ALLOWANCE_M. Code that took the allowance back off a length,measured - 2 * END_ALLOWANCE_M, must subtract twice the path'sallowanceorendAllowance(cable);END_ALLOWANCE_BY_MEDIA[media]is the table alone, and would leave the result 0.2 m long. - The per-media table is
END_ALLOWANCE_BY_MEDIA(@portrayal/kit0.18.0, #962). In 0.16.0 and 0.17.0 its name differed fromendAllowance(cable)only by case, for figures 100 mm apart. No kit version after 0.2.0 is on npm, so no published kit carried that name. The table is the sourced part alone;endAllowance(cable)and a path'sallowanceare what a length adds an end, the table's figure and the dressing allowance. The old name is not kept as an alias. No figure and no routed length changes. - L44 also reports decor whose box lies wholly outside its view's drawing - the face plus every placement the default build draws beyond it - where it is never seen (#878).
- Lint L43 stands down when the body itself is as wide as the rack face
(
chassis.widthat or above the generic ear's 480 mm threshold,ears.EAR_WIDE): a blanking plate's ears are built into its face, so the face is the part (decided 2026-10-09). A body narrower than that, drawn with a rack-wide front and nothing seated in its ears, still warns. No existing device changes; L43 had no hits in the library. chassis.airflowtakestop-to-bottom: air drawn in at the top face and pushed out of the bottom, as a rack fan tray blowing down through the rack does. It exports astop-to-bottom, NetBox's own value; Nautobot's device type has no airflow field. The FS FANS1U2F and FANS1U4F state it.common/rocker-switch@1(1.2.0) takes arocker-colorfield that tints the rocker. Empty by default, so every existing rocker draws as before; its two surfaces' 3D sides now follow the painted art. The FANP3U3F's rocker is red. WS-C4948E (0.1.4) and GL-12xB-240D (0.1.5) take a patch for the new part.fs/cmh-4drb1u-ring@11.1.0 declares its ring guide, a 37.2 x 74.8 mm opening run along the rack, so every FS ring carries one.fs/cmh-4drb1u1.0.2 for the composed change; its drawings gain only the guide attributes.fs/uscmh-sfdabs1u,fs/uscmh-sfdabs2uandfs/uscmh-sfdabsb1u0.1.1 carry an ESTIMATED cable capacity (33, 116 and 70 Cat6 24AWG cables at 100% fill), which FS states nowhere for these ducts: each channel's cross-section at 39.9 mm2 a cable, the ratio in the capacities FS does state for the CMH-SFD1U, CMH-DFD1U and CMH-SFD2U.cable-capacity-basissays it is an estimate, and the vendor-silent gap stays, noting the figure carried.- devicelock keeps
chassis.ears.handyas surface now that an ear is drawn from them, since that ear is never in a published face; the reasoning is indocs/format-stability.md, which also now says a kit's missingdescriptionis published as an empty string, as the code always wrote it. - UfiSpace grounding points are one M4 pair host where they were two
common/ground-lug@1studs 11.0 or 13.0 apart (#830). The accessory lug is fixed with two M4 screws, and the flank figures of seven guides - three distinct drawings, one shared by four guides and one by two - read the holes 15.6 to 15.9 apart, the 5/8 in. pattern; each landing is re-anchored where its own figure puts it, about 16.4 behind the front face. Breaking for anything holding the old placement idsground-1andground-2, nowground-screws; each device takes one major: M3000-14XC 4.0.0, S9500-22XST 3.0.0, S9501-28SMT 4.0.0, S9502-16SMT 2.0.0, S9510-28DC 6.0.0 (its two stand-in cutouts and its unsourced flank GND legend are gone), S9510-30XC 4.0.0, S9511-20CT 3.0.0. The second grounding location the 302 mm guides draw is recorded as a gap, not drawn. - UfiSpace S9601-104BC (4.0.0): the grounding lug is on the LEFT flank at its
rear end, as HIG Figure 20, the vendor render and the boss on the rear
elevation show, not on the rear strip.
ground-1, the upper hole of a pair drawn on the rear, is gone with the pad behind it;ground-screwsis one M4 pair host on the left view, its depth estimated and a gap saying so (#830). - Edgecore grounding plates drawn as one stud are their two screws (#830):
common/ground-lug@1on the screw the printed earth symbol sits by andcommon/ground-screw@1on the other, so each plate keeps one symbol. No pair host fits:- DCS500 (3.0.0): each plate is
ground-1andground-1b,ground-0andground-0b, M5, 17.2 apart on the datasheet rear, which is no two-hole lug pattern, and a gap records it. The 14 x 7 cutouts are gone: the plates are plain; - EPS112 (2.0.0), EPS203 (2.0.0) and AGR560 (3.0.0):
groundis nowground-1andground-2, one above the other, 16.3, 16.2 and 16.1 apart as read off the rear photographs and datasheet elevations, unsized because no document names the screw. Breaking for anything holdingground.
- DCS500 (3.0.0): each plate is
- Ground points drawn as two studs, or as one stud standing for a pair, are one
pair host at the pitch of the two-hole lug their documents call for (#828,
#830). Breaking for anything holding the old placement ids; each device
takes one major:
- the eleven Amphenol 300CB08 panels (300CB08, -C, -SC, the six nrg300CB08
CTRL and SENS versions, nrgILS300CB08 and its -SC), 2.0.0: each of the three
landings is
common/ground-stud-pair-5-8-1-4@1at 15.875 (was twocommon/ground-stud@115.9 apart), idsground-bottom,ground-left,ground-right; - Edgecore AIS800-64D and AIS800-64O, 4.0.0:
ground-screws, onecommon/ground-stud-pair-5-8-m6@1(wasground-screw-1and-2, 16.2 apart). The 5/8 in. is inferred from the lug the guide names, and a gap says so. The earth symbol above the plate is drawn; - Nokia 7360 FX-16 (nfxs-d-ba), 1.0.0:
ground-leftandground-rightarecommon/ground-stud-pair-1-1-4@1; FX-8 (nfxs-e-bb) and FX-4 (nfxs-f-bb), 1.0.0:groundiscommon/ground-stud-pair-3-4-1-4@1, stood on end; - Nokia Lightspan MF-8 (lmfs-f), 1.0.0:
ground-studs, onecommon/ground-stud-pair-5-8-m6@1at 15.875 (wasground-stud-1and-2, 16.3 apart): the manual's 16 mm (0.63 in.) is 5/8 in. rounded. Its ESD point moves out ofgroundinginto its own group,esd(#866).
- the eleven Amphenol 300CB08 panels (300CB08, -C, -SC, the six nrg300CB08
CTRL and SENS versions, nrgILS300CB08 and its -SC), 2.0.0: each of the three
landings is
- Casa C40G (0.5.16): no change to the terminal. Its
ground-stud-countgap records that the guide's lug points at 5/8 in. and at horizontal or vertical mounting, and why the pair waits. - The Juniper MX ground studs are pairs a two-hole lug spans (#828), each
device a major.
juniper/mx802.0.0,mx2402.0.0 andmx4802.0.0 (a vertical pair, was 14.0 / 13.2 / 13.2 apart) andmx1043.0.0 (was 16.0) place onejuniper/mx-ground-stud-pair-5-8@1at the 0.625 in. their guides state;mx1502.0.0 placesjuniper/mx-ground-stud-pair-3-4@1at 3/4 in., inferred from the lug its guide names (was 13.0). The placementsground-stud-0andground-stud-1are gone: the pair isground-studs, its studsground-studs/1and/2.mx2044.0.0 seatsjuniper/mx204-ground-plate@2, two 10-32 screws on the guide's 0.75 in. (@1 drew 16.0, and is removed); the plate is the pair, its screwsground-plate/1and/2.mx3044.0.0 seatsjuniper/mx304-ground-plate@2, two M6 screws one above the other on 5/8 in., the guide's "0.63-in. (16-mm) centers" (@1 drew 16.0, and is removed); its screws areground-plate/1and/2. - ESD jacks on the MX80, MX150, MX204, MX240, MX304 and MX480 are in a group of
their own,
esd(Point, furniture), notgrounding(#414). The MX204's laser label moved fromgroundingto a newfurnituregroup. A placement moving group is breaking for anything that addressed it by group. - L116's depth arm reads where a spanned part PRESENTS, its placed
liftplus its own seat out, rather than itsliftalone. Nothing the library placed before changes: an LC bore presents at its own face. A stud presents at its top, which is where a lug across a pair lies (#828). <device>.configs.jsonpublisheschassis.earsas an object, always: the bareears: behindis{"behind": true}, and an object is published with the keys it states, lengths as floats (#907).fs/uscmh-sfdabsb2u, the one device that statesears, publishes{"behind": true}where it published"behind", and its NetBox and Nautobot exports gain one comment line saying its ear flanges fold back behind the body. The string form was never in a release. Documented indocs/format-stability.md.- The L5 catalogue text says what the rule checks: no placement ref, and no
bay's
acceptsordefault, is akind: kit. - Lint L109 judges a polarity only at a width a held source draws it at
(
POLARITY_WIDTHS: Type A and AF at 12 and 24 fibres, universal at 12, all from the FHD MTP-12/24 Cassettes Datasheet). At any other width it warns "polarity not judged at this width" instead of passing or failing a generalisation (#524). One library part is affected:fs/fhd-fap12mtp16-a@1declares Type A on twelve MTP-16 adapters, a width no held source draws Type A at, and now carries that warning where it used to pass. - Every horizontal Juniper MIC is its own plate, 168.8 x 29.2, measured off
the MX104 and MX80 front photographs (#261). It was the estimated 168 x 27
"window". The 20 single-wide MICs take a major (
juniper/mic-3d-4xge-xfp@2 to @3, the others @1 to @2) and their art is re-enveloped, not redrawn. The two dual-wide MICs,juniper/mic-3d-40ge-tx@2andjuniper/mic3-100g-dwdm@2, are one 338.1 x 29.2 plate across both MIC slots, as the MX2010 photograph shows a dual-wide MIC. - The MICs the photographs show are drawn from them:
mic-3d-2xge-xfp@2has its cages at 45.4 and 91.75 along the plate, where they were at 25.75 and 54.75.mic-3d-4xge-xfp@3has its cages at 31.8, 65.9, 99.8 and 133.7, a 34.0 pitch, read off the MX2010. The Figure 31 reading it replaces was about 3% stretched.mic-3d-20ge-sfp@2has its two five-cage blocks centred at 46.85 and 121.4.
juniper/mpc1e-3d@3,mpc2e-3d@3andmpc3e-3d@3: the two MIC bays are the measured plate, abutting at the card plate's centre (x 37.7 and 207.0, y 0.15).juniper/mx1044.0.0: the MIC bays sit on the measured 169.3 pitch (x 17.8 / 187.1; it was 175.2) and at rows y 42.6 / 74.1, which were 6 to 7 mm low.juniper/mx803.0.0: the MIC bays sit at x 28.7 / 198.3, y 6.5.juniper/mx2404.0.0,juniper/mx4804.0.0 andjuniper/mx9603.0.0 seat the @3 carriers.juniper/mx2008,juniper/mx2010andjuniper/mx20201.0.0:- Each LC slot seats the new adapter card. The slots are the adapter's 43.18 x 449.8 on a 43.18 pitch, which three front photographs confirm. They were an estimated 41.0 x 425.0 on 41.0.
- The native MX2K cards and the slot blank keep their estimated size, centred in the slot.
- The MX2010 gains a
photographedexample configuration.
nokia/m2-oc192-xp-xfp1.0.1 namesjuniper/mic-3d-1oc192-xfpwithout the major it retires;nokia/sr-7andnokia/sr-12take the patch.- Deprecated, not deleted: each part below stays in the library, marked
superseded-by:its replacement and given a patch bump, so a manifest that pins it still resolves (#448). No device seats them any more.- The eleven MX2000 vertical card twins,
juniper/<base>-v2k@1formpc-3d-16xge-sfpp,mpc1e-3d,mpc2e-3d,mpc3e-3d,mpc4e-3d-2cge-8xge,mpc4e-3d-32xge-sfpp,mpc5e-100g10g,mpc5e-40g10g,mpc7e-10g,mpc7e-mrateandms-mpc, each superseded byjuniper/<base>@2(@3for the MPC1E/2E/3E), which the MX2000 slots seat insidejuniper/mx2000-lc-adapter@1. - The twenty vertical MIC twins,
juniper/<mic>-v@1(mic-3d-4xge-xfp-v@2), each superseded by the horizontal MIC's new major.juniper/mx-mic-blank-v@1is live, because the native MPC8E and MPC9E seat it. - The old majors of the 22 MICs, blank included (
@1;mic-3d-4xge-xfp@2), and of the three carriers (@2), each superseded by its next major above.
- The eleven MX2000 vertical card twins,
- The DCIM module export leaves out a contract that carries
superseded-by:. A retired major shares its successor's model, and exporting both wrote one file twice.components.jsonnow carries thesuperseded-byfield. - The MPC1E, MPC2E and MPC3E carriers (
juniper/mpc1e-3d,mpc2e-3d,mpc3e-3dand the-v2k/-v960form of each, 1.2.0) are each their base SKU and nothing else (#417).power-draw-max-wis the base row of the MX240 guide's Table 93: MPC1E 175 -> 165 W, MPC2E 294 -> 274 W, MPC3E 440 W. Each bay'sacceptsis exactly that SKU's column of the Interface Module Reference Tables 10-12, so the MPC1E no longer takes the 4x10GE XFP, the 10GE SFP-E, the ATM or the three channelized/CE OC3 MICs, the MPC2E no longer takes the 10GE SFP-E, the ATM or those OC3 MICs, and the MPC3E no longer takes the 4x10GE XFP, the 10GE SFP-E or the ATM MIC; the MPC3E now takes the OC192 XFP, both multirate OC3/OC12/OC48 MICs, the DS3/E3, the MACsec 20GE and the MS-MIC-16G.model-variantskeeps only the SKU that shares the row and the column (MX-MPC1-3D, MX-MPC2-3D). The queuing, P and NG SKUs are not these contracts and will be their own parts. The MX240, MX480, MX960, MX2008, MX2010 and MX2020 take a patch. - BREAKING for DCIM data already imported: the MPC3E module type is now
named by its part number,
MX-MPC3E-3D, not its component nameMPC3E(#417). Its NetBox and Nautobot module-type file is renamed to match, and an import keyed on the old model creates a second module type rather than updating the first. - BREAKING for DCIM data already imported (Nautobot): no carrier now
takes
MIC-3D-10GE-SFP-E(#417; it fits only the NG MPCs, which are not modelled yet), so its Nautobot module type names its ports{module}/port-0-Ninstead of{module.parent}/{module}/port-0-N. The six MICs no carrier takes say so inunplaced:. juniper/mic-3d-4xge-xfp@2andmic-3d-4xge-xfp-v@2(2.0.0): the four XFP cages are re-laid from the Interface Module Reference's Figure 31 (g100580), measured on the embedded image and scaled on the 19.5 mm XFP opening, at a pitch of about 32.7 mm instead of the guessed 22.0 and 21.1 mm (#238). The card keeps its size. The MPC2E carriers seat the new majors. The cage positions are ESTIMATED: photos of the MX104 and MX80 put the MIC plate at 168.6 mm and the XFP bezel at about 21 mm, which would make the figure's pitch about 35 mm; #261 re-measures this MIC from the MX104 photo.generic/qsfp-mpo@1andgeneric/qsfp-dd-mpo16@1(1.0.2) default the pull tab to the neutral grey#6f6f6f, not beige (#773). Beige is SFF-8679's code for 850 nm, and an MPO face is also the face of single-mode PSM4, DR4 and DR8 optics, so the generic drew those as multimode. A vendor wrapper states the colour its wavelength calls for, as it does ongeneric/qsfp-lc@2; no wrapper in the library composes either generic yet.- The MX240, MX480 and MX960 card is one part, drawn once: the 22 horizontal
MX card contracts (
juniper/scb-mx,dpc-r-4xge-xfp,dpce-20ge-2xge,dpce-2xge-xfp,dpce-40ge-tx,dpce-q-20ge-sfp,dpce-r-40ge-sfp,mpc-3d-16xge-sfpp,mpc10e-10c-mrate,mpc10e-15c-mrate,mpc1e-3d,mpc2e-3d,mpc3e-3d,mpc4e-3d-2cge-8xge,mpc4e-3d-32xge-sfpp,mpc5e-100g10g,mpc5e-40g10g,mpc7e-10g,mpc7e-mrate,ms-dpc,ms-mpc,mx-dpc-blank) are @2 at 413.5 x 29.5, the ejector-lever envelope of Juniper's Visio stencil, with a 396.0 plate centred in it, measured off the MX240, MX480 and MX960 front photographs (#261). Their art is re-enveloped, not redrawn. The levers, the model name and the OK/FAIL status group are re-placed from the photographs, and the MIC windows ofmpc1e-3d,mpc2e-3dandmpc3e-3dfrom the MX2010 photograph's ratios. On the 13 layout-derived cards, the port layout moves 8.4 mm right to clear the lever.mx-dpc-blank@2draws the blank's own short knobs and its 0/1 mark instead of card levers. juniper/mx2403.0.0 andjuniper/mx4803.0.0: every card slot is the card's 413.5 x 29.5 envelope at x 28.5, centred on the measured plate, with a 396.0 x 29.5opening. The slot pitch is 31.0 on the MX240 (was 30.45) and 31.3 on the MX480 (was 31.86; the photograph reads 31.2-31.5). The grey slot-number tab strip the plates no longer cover is chassis decor, with the slot numbers on their tabs. The MX480's front scale note is corrected: the photograph is isotropic to 0.8%, not 5.1% anisotropic.juniper/mx9602.0.0: its fourteen slots seat the same horizontal cards atrotate: 90, footprint 29.5 x 413.5 with a 29.5 x 396.0opening, on a 31.0 pitch (was 30.1). The SCB slots takejuniper/scb-mx@2(superseded:@3at 0.2.0, #891), so an MX960 SCB now offers the RE-S-2000 as well as the RE-S-1300. The MX960 device type'sAccepts:descriptions name the horizontal cards. Each module type's export comments now name one fewer author.smartoptics/ppm-ad1-1510@2andppm-ad1-1625@2(2.2.0 to 2.3.0) state their add direction as acombineonto Line Tx, from the signal-flow figures of ds-ppm-r4.0. It was written as banded legs off the line port while the vocabulary had no combine. The glass is the same: every port and every fibre-map row is what it was, and the fibre maps do not change at all.smartoptics/dcp-2composes both and takes the patch the lock asks for (2.1.2 to 2.1.3). The only lines of any export that move are the version sentences incomments: the contract version on the two filters' module types and the drawing version on the DCP-2 device types.docs/optical-paths-design.mdrecords the combine form, how a path reads in both directions, and thatoptical.trunkis the statement of an endpoint's role: a position it names, or a rear face carries, is a trunk, and every other routed position is a branch.- Lint L108 now checks stacked OSFP cages, which it used to skip. A stacked
OSFP cage is one connector that seats both modules heat sink up (OSFP MSA
rev 5.22 section 7.1, Table 7-1, Figures 7-1 and 7-2), so an OSFP pair has
to be turned alike: 0 over 0, 180 over 180 for a cage on the underside of
the board, or both 90 or both 270 on a card drawn on its side. SFP, QSFP
and QSFP-DD stacks are still belly-to-belly (upper 0 over lower 180). An
OSFP pair turned 0 over 180 needs a recorded reading in
stack-exceptions:(#799). edgecore/ais800-32o2.0.0: the lower OSFP row is now drawn the same way up as the upper (rotate 0), as the quick start guide's elevation and its install render show. Two optics seated in one column no longer overlap nose to nose by 1.66 mm. 0.06 mm of overlap remains because the drawn row pitch is 14.54, against the MSA's 14.90. Its DCIM exports change in the drawing version line only (#799).celestica/ds4100andcelestica/ds41010.1.1 keep their lower OSFP rows turned 180, and now say why: each install guide's elevation draws the lower cage as the upper turned over. Their 18.9 and 18.4 mm row pitches leave room for a board between the rows, so these are single cages on both faces of one board rather than stacked cages. Each pair is named instack-exceptions:(#799).celestica/ds5000,ds60000.1.1,ds60010.1.2 andedgecore/ais800-64o4.0.1 keep their OSFP turns for now. Each pair is named instack-exceptions:, and a newstacked-osfp-orientationgap says what would settle it. Their drawings read as the lower bank turned over (0/0 over 180/180), which neither the current geometry nor the first #799 proposal matches.ufispace/s9321-64eo1.0.16 corrects a provenance note that still said OSFP stacks were not checked (#799).offin the Explorer is a state that can be lit, not only the absence of one: theoffchip setsstate-offon an outlet (so a G4 outlet lamp shows its declared red, or a lamp-less outlet dims) and on any element that declares a colour foroff, and clears only a lamp or a plain element with none, as before.states.jspaintsmeasures a declaredoffrather than assuming it. A custom lamp colour is not shown on a lamp that isoffhowever it came to be off - its own mark, another mark, or its outlet - in 2D as in 3D.juniper/mic-3d-4xge-xfp@4: the four ports are named for the module reference's pic/port numbering (Figure 31: [0/2]0, [0/2]1, [1/3]0, [1/3]1),port-0-0,port-0-1,port-1-0,port-1-1, asmic-3d-2xge-xfpnames its two; 3.x named themport-0-0toport-0-3. Each port gains its LINK lamp,led-link-<pic>-<port>, with the reference's states (off, green on link) (#887).@3is retired withsuperseded-byand stays accepted byjuniper/mpc2e-3d@3(3.1.0), which now accepts@4too.juniper/mx20102.0.0: its vendor-photo configuration seats the new MIC in LC0 and LC6. Breaking for DCIM data already imported: the third and fourth port of each of those MICs is renamed.mx2008,mx2020,mx240,mx480andmx960take a patch for the carrier change.juniper/dpc-r-4xge-xfp@3: the four XFP ports sit on the 76.1 mm pitch the MX240 and MX480 photographs agree on (card x 105.55 to 333.8, y 18.85), with each port's TUNNEL and LINK lamps side by side to its left and its legends printed upward, as photographed; 2.x had them on a 53.4 pitch from x 95.5 (#891).juniper/scb-mx@3: the Routing Engine bay is 271.9 wide, to the right end both photographs put the RE plate at (it stopped 9.5 mm short), and the SCB's two panel screws are where the photographs show them (#891).juniper/re-s-1300@2andjuniper/re-s-2000@2take the same width and draw the plate's right captive screw.juniper/dpce-r-40ge-sfp@22.1.0: the card's own OK/FAIL lamp under its legend, with states ok, fail and absent from the module reference (#891, #899).juniper/mx2405.0.0,juniper/mx4806.0.0,juniper/mx9604.0.0: their slots accept the new majors. Ports keep their ids.juniper/mx1045.0.0: the fixed panel and the supply/Routing Engine band re-placed off the front photograph on its checked scale (#901). The four XE ports are discretestd/sfp@1cages on a 17.2 mm pitch at y 28.2 (they were a ganged row at 14.25, y 25.2); the ALARM connector, the ONLINE/OFFLINE button, the SYS OK lamp, the timing RJ45s and SMBs and their legends move to the photograph's positions; the band starts at y 105.5, the second supply moves 8 mm left and both Routing Engines 36 mm left, with the side cover beside them. The fixed-panel decor stops at the MIC plates, y 42.4.juniper/mx804.0.0: the fixed XFP cages on the photograph's 31.3 mm pitch at y 71.4 (29.4 before), with their LINK lamps right of each cage; the console, AUX, Ethernet, USB and clock jacks, the status lamps and the button re-placed on the same scale; the USB jack lies horizontal, as photographed (#901).- Both devices gain a gap for what the photographs show and nothing draws yet.
- MX2000 upper cages on the guides' 1.7 in slot (#902).
juniper/mx20103.0.0 andjuniper/mx20202.0.0 place CB-RE 0, SFB 0-7 and CB-RE 1 as ten 43.18 x 412.1 mm slots (1.7 x 16.225 in, the guides' physical tables) over the line-card slots, as the front photographs show; they were 55- and 40-wide estimates, 405 high.juniper/mx20082.0.0 does the same at the photograph's 182 mm height, y 109-291 (it was 170 high at y 143); its guide's Table 98 rows for the MX2008 RCB (16.225 in) and SFB2 (16.23 in) carry the MX2010's heights, and the disagreement is recorded as a gap. - New majors at the new size:
juniper/mx2000-cb-re-v@2,mx2000-cb-re-128g-v@2,mx2000-cb-re-1800-v@2,mx2000-sfb-v@2,mx2008-sfb-v@2andmx2008-rcb-v@2. Their faces are re-centred, not re-read; port ids are unchanged. juniper/mx4805.0.0: the front vent band and the front ESD point are re-placed on the photograph's body scale (#892). The band now runs x 19.5-417.6, y 4.7-30.6 (it was 310 mm wide at x 20), and the ESD jack, its cutout and its mark move from (8, 20) to (16.1, 28.2). Both had been read at the ear-inclusive 3.379 px/mm scale the 3.0.0 slot rework retired.juniper/mx960-blank@11.1.0 carriesmodel: DPC-SCB-BLANK, the MX960 guide's Table 5 part number (#899). Breaking for DCIM data already imported: its module type is renamed frommx960-blanktoDPC-SCB-BLANK.juniper/mx960-craft@2: the fourteen slot clusters sit where the MX960 photograph puts them relative to the slots, at 16.65 + 31.40 k, instead of on the retired 30.1 slot pitch (#899).juniper/mx9605.0.0: a new orderableacconfiguration, the chassis as photographed (DPC 40xGE in slots 1 and 3, DPC 4x10GE in 7 and 9), so a seated, turned line card renders in the build and in CI (#899).juniper/mx2405.0.1,mx4806.0.1,mx960: aslot-pitchnote on why the three chassis read 31.0, 31.3 and 31.0 for one card, and why the guides' 1.25 in is the card's height and not a pitch (#899).eaton/evmi2130x0.2.0:metering-scope: branchandoutlet-switching: false(classmetered-branch), the structured input keys withinput-plug: nema-l21-30pand its voltage prose moved intoinput-ac,lineson its three breakers (A L1-L2, B L2-L3, C L3-L1) andthroughon its 42 outlets. Its exported outlets now say which breaker and lines they are on, and its input power port carries the rating. No outlet statesfeed_leg: every one is line to line.eaton/g4-mounting-button@11.1.0:mates: pdu-buttonand amatepoint on its axis.- Routed lengths start at the plug's reach (
@portrayal/kit0.13.0, #960;docs/cable-lay-design.mdsection 1.5). A cable leaves the far end of its plug, so eachroutePathnow starts and ends with a straight stretch out of the port's face, to a new pointat: 'reach'(withend), and its first and last legs, their detours included, run from there. The reach is the page'sctx.plugReachOf(end, cable)when it gives one, elsePLUG_REACHby media: 27.6 mm for LC fibre (generic/lc-plug@2 and common/lc-boot@1), 39.4 for copper and a cable with no media (generic/rj45-plug@1 and common/rj45-boot@1, with the boot taken to abut the plug, so it may err long by a few mm), 64.8 for a DAC or an AOC (generic/qsfp-cable@1). The 0.15 m end allowance is unchanged at 0.13.0 (kit 0.16.0 replaces it with a per-media allowance, #962): it is the dressing slack, and the plug was always along the first leg, which the reach turns into a dog-leg rather than lengthening by a plug. Almost every routed length grows, by what the dog-leg out of each plug adds (median about 43 mm on a 780-cable sample) and by up to about 0.33 m where the reach puts a leg over a tray floor, so it goes round the tray's front edge; one cable in six to eight moves up a stock size. On the reference rack of #949, c7 and c9 to c14 move from 0.5 m to 1 m stock (c9 to c12 measured 0.494 to 0.496 m from the port faces, 0.517 to 0.524 m now). A saved rack's routed lengths and stock sizes are re-measured the next time a page measures them; an entered length is never touched. A plug in a panel port behind a deep shelf is now acrosses-bodyfinding ("at its port on ..."). patchwith a newcfgand noswapsorfieldsclears both; naming the default of a device whose file leavescfgempty is no change. With parts lists loaded,placeandpatchrefuse a configuration the device does not list, andpatch {swaps}leaves out, and names, what a slot does not take.describestarts with a totals line (Rack 1 (r1): 6 items, 40 cables.); the frame follows on its own line.- The command descriptions name no function and no page:
describe(),freePorts(),catalog()and the Explorer are gone from them. fs/cmh-6dr1u1.0.0 draws its front at the 482.6 mm rack face with its ears, and its two end rings 43 mm past each, where they were a gap; it statesoverhang: {left: 43, right: 43}. Its D-rings move 26.3 mm right on the wider face; the moved geometry takes the major. Its DCIM exports gain the overhang comment.nokia/lmfs-f1.0.1 statesoverhang: {right: 47}, the reach of its horizontal front dust filter past the right flange, which it already drew in the front-cover configuration; nothing on the drawing moved. Its DCIM exports gain the overhang comment.- A drawing bigger than its face (a part beyond it grows the viewBox) carries
the face it declares as
data-face-wanddata-face-hon its root, and the 3D viewer lays the face out on that rather than on the drawing's extent, so the face is centred and a part beyond it stands beyond the plate. A drawing that fits its face is unchanged. A sheet body's rack face builds no 25.4 mm plate (#865). - The rule for a retired component major is stated the same way in
spec/DESIGN.mdsection 9,docs/format-stability.mdandlibrary/components/README.md. While the package is at 0.x, a superseded major may be removed, and every removal is listed inCHANGELOG.mdwith the ref that replaces it. The deprecation mechanism is required before 1.0: thesuperseded-by:marker, a stated support window, and L89 telling a deprecated major from a dead one. No lint behaviour changes (#448). library/components/README.mdsays that moving decoration nothing addresses, inside an unchanged part outline, is a minor bump, and namesfs/d-ring-snap-in@11.3.0 as the precedent (#968).@portrayal/kit0.5.0: a routed cable passes THROUGH a D-ring along the ring'srun, not to a point inside it (#930). Each ring waypoint becomes the point where the cable enters, on the side of the point before it, and the point where it leaves, half the ring'sdeptheither side of its centre, with a straight run between them. A ring that states no depth is taken asRING_DEPTH, 10 mm, marked estimated. The newroutePath(rack, cable, ctx)is that path, and it decides each ring once, in the rack's frame: which way through, or not through at all.routedLength(pathLength),fill,capacityOverandinspect(route.rings) read it, andringMarks(rack, cable, ctx)hands its decisions to the drawings:routed2dandroutePoints3dtake them as an optional last argument, draw each ring the way it was decided, and round their corners outside it (throughRingsinrack/route-path.js). A mark's sense is in the rack's axes; a drawing that flips one turns its marks withorientMarks(a front elevation{y: -1}, the mirrored rear pane{x: -1, y: -1}), andreverseMarksserves a path drawn from its other end. A route that would enter and leave a ring by one face is not drawn through it, is counted neither in that ring's fill nor in its manager's capacity, and is reported byringFindings(rack, ctx). A point further off the run in the face than along it (a port well below the ring) stands on neither side; a manager's stand-off out of the face does not count. The automatic route takes only the rings on the way from the port to its gutter, no longer a ring behind the port. Routed lengths change: a ring adds up to its depth, and a cable whose automatic route used to double back through a ring is up to about 100 mm shorter. Stored routed lengths are re-measured the next time a page measures them; an entered length is never touched. Ducts and pass-throughs keep a single point. The Rack Builder's half (re-vendoring, passingrunand the ring marks to the drawings, showing the findings) is listed indocs/cable-managers-design.mdsection 13.- A ring is solid, and a route enters it through its opening
(
@portrayal/kit0.15.0, #968).solidsOfplaces a ring's parts with the other solids;legCrossingsanddetourmeet them with the cable's tube, the part grown by its radius, so a leg that would graze a leg or the bar is gone round. A zero-U part (a PDU in the gutter) is met by the tube too, so a leg to the lane beside it never runs across its outlet face. Every pass through a ring whose opening is placed starts and ends at an approach point on the run outside the band, the cable's radius andCLEARpast it (at: 'approach'), so a detour or a leg from behind or below ends there and the cable enters along the run; a ring a route would double back at is gone to as far as that point (the path'sfacepoint, where the ring's ownfacestays on the band).bodyFindingsnames the part ("ring 3 front leg") and says to "route it into the ring along its run, through its opening". ONE-WAY: routed lengths change on saved racks. On the reference rack of #949 the upper leaf's cords grow 10 to 38 mm (five now go over their ring to the approach point on its far side) and the lower leaf's 2 to 6 mm; c2 and c3 pass the 0.5 m stock break. On generated racks lengths move by up to about a tenth of a metre either way, depending on the layout: one sample of 3,120 cables (one layout and seed) gave -89 to +131 mm, median +10, 67 stock sizes up and 67 down; an independent sample of 3,962 cables gave -94 to +94 mm, median +4.5, 67 up and 27 down. A saved rack's routed lengths and stock sizes are re-measured the next time a page measures them; an entered length is never touched. - Automatic routes and routed lengths change (
@portrayal/kit0.12.0, #949;docs/cable-lay-design.mdsection 4.1, pulled forward from step 5). A cable whose two ends leave through the same manager on the same face runs along it, port to port, through the rings whose centres lie between its two ports, and no longer goes out to the side lane and back; with no ring between, through the ring nearest the middle of its two ports (of two as near, end a's side; the nearest one it passes through, when one does), so never direct. Any other automatic route takes the gutter both ports stand on, or, when they stand on opposite sides of the centre line, the side whose path is the shorter (end a's side on a tie, or when a port is not found); before, the side was end a's alone. On the reference rack of #949 every one of its sixteen cords changes, from 0.67 to 1.04 m by the lane to 0.43 to 0.50 m along the lacer (stock 1 or 1.5 m to 0.5 m); on a sample of 780 cables between six devices, a fifth to a quarter change, every one shorter. A saved rack's routed lengths and stock sizes are re-measured the next time a page measures them; an entered length and a route edited by hand are never touched. - Fewer doubles-back ring findings (#949, #930's rule): a cable whose
route reaches only a short way past its port into a ring just beyond it is
held by the ring and not reported. Short means the nearer neighbour along
the run is a port, and the ring's near face is no further past it than the
ring's depth plus the cable's diameter (the diameter counted at most up to
the depth); a turn-back just past another ring or a lane point, or further
off, is a hook-back and is still reported. Such a cable now passes the ring
(
held: trueonroutePath's ring,back: falseon its mark), is drawn through it, counts in its fill and its manager's capacity, and measures its reach through the ring longer (about 8 to 14 mm on the FHD-CMP5DR). The rule is inthroughRings, so hand routes and automatic ones agree. Saved hand routes that were findings can lose them; the saved routes on the reference rack of #949 had none before or after. - An automatic route can carry a doubles-back finding. A patch along one
manager with no ring between its ports goes through the nearest ring even
when it cannot pass it or be held by it: a cross-connect on one panel from
bay 3 lc2 to lc5 behind an FHD-CMP5DR takes ring 3, 31.5 mm past lc2, and
ringFindingsreports it. Before, automatic routes never doubled back. - The descriptions in the six JSON schemas say what each field is, what it
takes and what it does, without citing repository paths, document sections,
steps or issue numbers, and without the history of how a rule came about
(#951). 132 of 553 descriptions changed; what validates did not. The reasons
that history carried are in
spec/DESIGN.md, under "Why some schema fields are shaped as they are". American spellings in the rack schema (millimeters, catalog) and in a few colour descriptions are now British. - A test records each schema's shape with its descriptions removed
(
spec/tests/fixtures/schema-shape.json), so a change to what validates is re-recorded on purpose, withpython3 spec/tests/test_schema_descriptions.py --update. Another rejects a description that cites a.mdfile,spec/,docs/, a section, a step or an issue number. - Lint L19 also reads a bay in a group whose role is
indicator: it statesfor:as a lamp placement does (#414). common/terminal-header-508-2@3andcommon/terminal-header-508-5f@2are drawn 8.6 high, the Phoenix Contact installed height, not the data sheets'hof 12.1, which counts the 3.5 solder pin under the board (#873). Both now claim their registry entries (terminal-508-2-header,terminal-508-5-header, whosehis now 8.6), and eachmatesits at 4.3, on the axis the 508 plugs already assumed. The ten AurCore AIS switches seat the new majors (2.0.0), each placement moved 1.75 so the header's centre stayed put. The three 508 plugs take patch bumps for their provenance.- A
sidekey on a lab placement is no longer refused by the lab schema: it is checked by L153 instead. L142 claims a rack-face part's unit per face and side; a lab with nosideanywhere resolves and checks exactly as before. - Routed lengths change beside a duct: a lane waypoint at a unit a zero-U
duct spans is measured at the duct's centre line, about 49 mm further out at
each end beside a 138.8 mm duct. Stored
routedlengths are re-measured the next time a page measures them. parseDockeepssideon an item, and gives azeroUentry with no id, or a repeated one, an id of its own.- A rack-face part is judged on every unit it spans, not only its bottom one,
and within the rack's height.
placeof a zero-U part is refused, namingzerou.place;removeandmovegiven a zero-U id name the command that takes it. Aframechange moves the parts beside the rack to their side of the new frame, or down to fit, and removes one that no longer fits, saying so.fitsZeroUtakesruas well asoffsetMm, and refuses a part that is not a zero-U part. describe's totals line counts the parts beside the rack when there are any, and a window takessection: 'zeroU';inspectof an item carriesside.- The tools are 0.2.0:
versioninpyproject.toml, and thegeneratorversion the compiler stamps into the metadata of every compiled face and into each elements file. Nothing else in a face moves with it. Every device package on npm takes an update at the next release run for that stamp.docs/maintainers.mdlists the strings that move at a release.
nokia/3fe54221ah1.0.0: thefront-openview is gone, with its two placementsfront-open/placements/security-screw-openandfront-open/placements/latch-screw-open. The inside of the housing is now on thefrontview, asnokia/3fe54221-interior@1behind the removable doornokia/3fe54221-door@1; the screws arefront/placements/security-screwandfront/placements/latch-screw. The device has no DCIM export.- BREAKING for DCIM data already imported. Five HPE parts are renamed, and
the old refs are gone. The DL160 Gen10's Media Module adapters take their
option numbers, as its supplies do:
hpe/media-module-872161@1is nowhpe/media-module-866464-b21@1,hpe/media-module-872162@1ishpe/media-module-866467-b21@1andhpe/media-module-872163@1ishpe/media-module-866470-b21@1; their NetBox and Nautobot module types are renamed with them. Two lamps that are shapes and not HPE products move tocommon/:hpe/led-sq@1iscommon/led-sq@1andhpe/button-led-sq@1iscommon/button-led-sq@1(#760). - Six Dell R660 component majors are superseded and removed, each replaced by
its
@2:dell/e3s-carrier-blank@1(redrawn as Dell's real E3.S blank), and the Gen5 risersdell/riser-2p-16g@1,dell/riser-2r-16g@1,dell/riser-3p-16g@1,dell/riser-3q-16g@1anddell/riser-3r-16g@1(now on the Gen5-printed cages). A manifest that pins an@1moves to the@2of the same name (#749). - Two Supermicro component majors are superseded and removed, each replaced by
its
@2:supermicro/riser-wio-rhs-x13sew@1(slot 3's bracket bay moved) andsupermicro/system-board-x13sew@1(the board is now flat art on the floor of an interior well). A manifest that pins an@1moves to the@2of the same name. The DIMM bays of the SYS-111E-WR, SYS-111E-FDWTR and SYS-111E-FWTR are renamed as the board names them,dimm-1..dimm-8todimm-a1..dimm-h1, in the drawings and in their NetBox and Nautobot device types. None of this was in a release (#782). edgecore/ais800-psu-dc@1, replaced byedgecore/ais800-psu-dc@2(#397). Element ids are unchanged;vent-fieldmoved and grew.common/terminal-header-508-2@1, which nothing places any more. Usecommon/terminal-header-508-2@2(#804). Superseded:@2was removed in turn (#873, below), and the major to pin at 0.2.0 iscommon/terminal-header-508-2@3.std/cxp@1, the 27.0 x 10.0 x 92.0 estimate; usestd/cxp@2(#802).std/cfp@1, the 82.0 x 13.6 faceplate-on-body envelope; usestd/cfp@2(#802).std/cfp2@1, the 41.5 x 12.4 module body; usestd/cfp2@2(#802).std/cfp4@1, the 21.5 x 9.5 module body; usestd/cfp4@2(#802).casa/ground-strap@1, replaced bycasa/ground-strap@2(#413). Itsbolt-holeelement has no successor: the jack is the composedjackpart.- fs/dinrail2u-panel@1, replaced by fs/dinrail2u-panel@2 (#971): the @1 panel was the rail's 400 mm wide and stood clear of both brackets.
- fs/dinrail4u-panel@1, replaced by fs/dinrail4u-panel@2 (#971), for the same reason.
common/drive-carrier-25@1, replaced bycommon/drive-carrier-25@2(#721). A manifest that pins@1moves to@2; a bay drawn at the@1size shows 2.6 mm of chassis between carriers.common/drive-blank-25@1, replaced bycommon/drive-blank-25@2(#721), for the same reason.juniper/mx204-ground-plate@1, replaced byjuniper/mx204-ground-plate@2(two 10-32 screws on the guide's 0.75 in. centres, presenting astud-pair-3-4; @1 drew the holes 16.0 apart) (#828, #830).juniper/mx304-ground-plate@1, replaced byjuniper/mx304-ground-plate@2(two M6 screws on 5/8 in. centres, presenting astud-pair-5-8) (#828, #830).MIC-3D-4COC3-1COC12-CElosesport-1-0toport-1-3:juniper/mic-3d-4choc3-1oc12@1drew eight cages in two PICs, while the card has four OC3/STM1 ports, numbered 0 to 3. The module reference states it and the MX104 photograph shows it.@2hasport-0-0toport-0-3, and the module type is written from it. BREAKING for DCIM data already imported.juniper/mic3-100g-dwdmleaves the MPC3E's MIC bays: it is dual-wide, and no bay can take a module that fills two (unplaced, asmic-3d-40ge-tx).- Nautobot module types
MIC-3D-4XGE-XFP,MIC3-3D-10XGE-SFPP,MIC3-3D-1X100GE-CFP,MIC3-3D-1X100GE-CXP,MIC3-3D-2X40GE-QSFPPandMIC3-100G-DWDMname their interfaces{module}/port-.... They were{module.parent}/{module}/port-.... The exporter writes the one-token name for a model seated at several depths or at none. The first five are now seated at two depths: in an MPC on the MX240 to MX960, and in an MPC inside the adapter on the MX2000.MIC3-100G-DWDMis seated nowhere, because no bay can take a dual-wide MIC (above). NetBox is unchanged. BREAKING for DCIM data already imported (Nautobot). Superseded for the first five by the Nautobot entry under Fixed (#917), which gives them{module.parent}/{module}/port-...again. Of the six, onlyMIC3-100G-DWDMkeeps the one-token name at 0.2.0. juniper/mic-3d-4xge-xfp@1andjuniper/mic-3d-4xge-xfp-v@1, whose cages were laid out from registry sizes rather than measured (#238). Pinjuniper/mic-3d-4xge-xfp@2andjuniper/mic-3d-4xge-xfp-v@2instead. Superseded: both of those are now kept only as deprecated majors (superseded-by, #448), and the major to pin at 0.2.0 isjuniper/mic-3d-4xge-xfp@4(#887).- The MX960 vertical card twins, each replaced by the horizontal card at
rotate: 90:juniper/dpc-r-4xge-xfp-v@1byjuniper/dpc-r-4xge-xfp@2,juniper/dpce-r-40ge-sfp-v@2byjuniper/dpce-r-40ge-sfp@2,juniper/scb-mx960-v@1byjuniper/scb-mx@2, andjuniper/<base>-v960@1byjuniper/<base>@2fordpce-20ge-2xge,dpce-2xge-xfp,dpce-40ge-tx,dpce-q-20ge-sfp,mpc-3d-16xge-sfpp,mpc10e-10c-mrate,mpc10e-15c-mrate,mpc1e-3d,mpc2e-3d,mpc3e-3d,mpc4e-3d-2cge-8xge,mpc4e-3d-32xge-sfpp,mpc5e-100g10g,mpc5e-40g10g,mpc7e-10g,mpc7e-mrate,ms-dpcandms-mpc(#261). Superseded for five of them:juniper/dpc-r-4xge-xfp@2andjuniper/scb-mx@2were removed in turn for@3(#891, below), andmpc1e-3d@2,mpc2e-3d@2andmpc3e-3d@2are kept only as deprecated majors whose replacement is@3(#448). Those five@3are the majors to pin at 0.2.0. juniper/re-s-1300-v@1, which onlyscb-mx960-vseated, is replaced byjuniper/re-s-1300@1injuniper/scb-mx@2. Superseded: both were removed in turn (#891, below), and at 0.2.0 it isjuniper/re-s-1300@2injuniper/scb-mx@3.juniper/mx960-blank-v@1is replaced byjuniper/mx960-blank@1, drawn horizontally with the MX960 blank's own knobs. Its DCIM module type is renamed frommx960-blank-vtomx960-blank, so the export filesmx960-blank-v.yamlare replaced bymx960-blank.yaml. BREAKING for DCIM data already imported. Superseded: the module type was renamed again, and at 0.2.0 it isDPC-SCB-BLANK, inDPC-SCB-BLANK.yaml(#899, under Changed).- The 22 horizontal card majors at @1, each replaced by its @2 above. The
major to pin at 0.2.0 is
@3fordpc-r-4xge-xfp,scb-mx,mpc1e-3d,mpc2e-3dandmpc3e-3d, and@2for the other seventeen. juniper/dpc-r-4xge-xfp@2, replaced byjuniper/dpc-r-4xge-xfp@3;juniper/scb-mx@2, replaced byjuniper/scb-mx@3;juniper/re-s-1300@1andjuniper/re-s-2000@1, replaced byjuniper/re-s-1300@2andjuniper/re-s-2000@2(#891). Nothing in the library seats them any more, so per #448 the superseded majors are removed rather than kept; a manifest that pins one moves to its replacement.- The six upper-cage majors the new sizes replace (#902), per #448:
juniper/mx2000-cb-re-v@1(now@2),juniper/mx2000-cb-re-128g-v@1(now@2),juniper/mx2000-cb-re-1800-v@1(now@2),juniper/mx2000-sfb-v@1(now@2),juniper/mx2008-sfb-v@1(now@2) andjuniper/mx2008-rcb-v@1(now@2). Nothing in the library seats them any more. juniper/mx960-craft@1, replaced byjuniper/mx960-craft@2(#899). Nothing seats it any more, so per #448 it is removed rather than kept.common/terminal-header-508-2@2, replaced bycommon/terminal-header-508-2@3, andcommon/terminal-header-508-5f@1, replaced bycommon/terminal-header-508-5f@2(#873). Element ids are unchanged.
- 3D kit: a
uhandlestandingin:a well rises from the well's floor, asout,cylandbaralready did, rather than from the face plane. amphenol-ns/tpa-fuse-holder-307492@1(1.0.1) keeps its fuse rating out of the drawing once the rating is set in a viewer. The rating is carried by the part and never printed, because the fuse is inside the holder; its text node was hidden by its owndisplay, whichkit/fields.jsremoves from a node it writes a value to. The node now sits in a group that is not displayed. The 300CB08 takes a patch, 1.0.1.- 3D kit (
swap.jsviewsToRewrite): a swap into a slot on a placed part that composes several slots and is no cage itself, such as a pole of a barrier terminal block (psu1-input/lug-2), now reaches the 3D scene. No bay and no cage of any view claims such a key, so no view was named, the face was never rewritten and the occupant showed in 2D only, with no warning. Every view is rewritten for such a key (#814). @portrayal/kit: the README's links to the Portrayal README and to the artifact contract are absolute GitHub URLs, so they work on the npm package page, where a relative link resolved against npmjs.com and broke. The package also names itshomepageand where to reportbugs. Neither is in kit 0.2.0 on npm, which was published before this change; both reach npm with the next kit publish (#716).edgecore/ais800-psu-dc@2: the vent lattice is 23.46 tall from y 13.56, measured module edge to module edge on the quick start's Connect Power figure, where 1.x drew it 20.12 from 15.01 (#397).edgecore/ais800-32d2.0.0 andedgecore/ais800-32o3.0.0 accept it.- The -C panels of the Amphenol Network Solutions 300CB08 family
(
amphenol-ns/300cb08-c,nrg300cb08-ctrl-c,nrg300cb08-sens-c) are 367.0 deep, front of the metal to the tops of the output receptacles, as their own bottom view (installation guide Fig. 3-13) measures, not the stud panel's 330.8; their bottom is re-read off that view. Their busbar landings (amphenol-ns/input-feed-busbar@1, 1.0.1) now stand 38.1 and 95.2 behind that, the two lengths the drawing dimensions, where both stood 147, a figure that subtracted a depth without the front guards from one with them (#860). Each of the three panels takes a major (2.0.0): its geometry moved, though no id or slot did. Their DCIM exports change in the drawing version line only. - The kit's
loadDeviceandloadStage(kit/shell.js) take a generation each call, and one that a newer load overtook stops after its await: it writes no device, configuration or view, mounts no drawing and emits noload, and its promise rejects with an errorisSuperseded(err)(exported) recognises. The stage holds exactly one drawing after any overlap. A host that awaited a load sees the rejection instead of carrying on with a stale target (#929). - A
fields=entry for a part drawn only on a face other than the one the link opens (a supply's wattage on the rear, a link opening on the front) is kept on reload: the shell fetches the other faces before judging the entry, asapplySwapsalready does for a slot on another face, and paints it when that face is mounted. It used to be ignored and dropped from the location (#818). - L132 resolves
fed-byper configuration, as the export does: an output every configuration has, fed by an input that only some configurations have (only-in), is an error naming the configuration that lacks it, where it used to lint clean and stop./publish.shwithNotExpressible(#857). - A breaker bay whose description is too long for its
; protects <outlet>clause now leads withProtects <outlet>;and shortens what it accepts after it. The clause is the only place Nautobot keeps the breaker-to-outlet link, and it used to be cut off. No bay in the library is that long, so no committed export changes (#857). - L129 refuses an
optical.trunkthat names one position of a multi-position front connector exported as one port (an MPO adapter): the export shrank the port and kept each leg's originalfront_position, which both DCIMs refuse. Name the connector bare (#857). - L39 asks each window a multi-window lamp declares to be more than half punched, where it summed them: a four-window lamp with three windows punched passed, and the missing window was never reported. Nothing in the library changes. Tests now pin the windows' turn at 90, 180 and 270 degrees on a part that is not symmetric (#845).
- L39 reads a composed leaf with no registry entry (no
conforms, no parts of its own, a size, and not a lamp, latch or printing) as the opening of the part that composes it, as_aperture_ofalready did, so the C100G's strap plate is checked against its jack's cutout rather than reported 4.5 mm off it (#413). - Every Casa lamp now declares the states it can show and is drawn off (#940).
The STATUS, ACTIVE and ALARM lamps on the line cards (BDM, BDM2, BDM2m,
DS 8x8/8x96/8x192, US 16x4/16x8, CSC 8x10G) and the SMMs (2x10G, 8x10G,
300G, 300GM) take
ok,activeandalarm, from the front-installed module LED tables of the C100G and C40G installation guides; STATUS and ACTIVE are no longer painted permanently green. The port lamps on the CSC 8x10G and SMM300G/GM takelinkandactivity(blinking), and the SMMs' management jacks colour their lamps green. The C100G fan and PEM lamps takeok,alarmand a bluehigh-speed(fan) oron(PEM, which the guide marks "Not used"). The C40G AC PSU's status lamp is now a declared element,casa/c40g-psu-ac@1status, withokandalarm; it was art painted green that no state reached. No element id changed. Each of the sixteen components takes a minor, and the C100G and C40G a patch. fs/dinrail2uandfs/dinrail4u0.1.1: the setback notes say the datasheet side views are embedded rasters (461 x 212 and 435 x 279 px, about 1.1 and 1.2 mm a pixel) read on an upsampled render, not vectors; the 2U note says the slot's front end is hidden under the screw head drawn at 69.4, which is where the front stop is taken (64.4 + 2.6 would be 67.0). The 51.2 mm front setback stands. The configuration-levelairflowdescription in the device schema and theconfigs.jsonairflow list inlibrary/README.mdnametop-to-bottom.eaton/pdumv20hvnetlx0.1.1: the frontlogo-zonemoves to (19.0, 677.0), over the wordmark DT01 shows, and the left view gains alogo-zonefor the upside-down EATON wordmark DT08 and DT01 show about 864 to 930 mm from the top end (the mark is not drawn). The side vent fields no longer carry a fill theirslotspattern replaces; the drawing is unchanged.- The device schema's
interfacesdescription and power-outlets-design decision 5 say that a NOS listing that states its owninterfaceskeeps every outlet's placement id, since it does not apply the hardware's own naming rules. generic/nema-5-20p-plug@11.0.1:provenance.pinsgives the blade centres 15.45 apart, as the Leviton drawing places them (6.31 + 9.14), not 15.49. The drawing is unchanged.components.jsonpublishes a turned bay with itsrotate(#718). Each component entry lists its own bays withat,size,acceptsanddefault, and left out the turn, so a consumer placing a card by the index landed it wrong in a turned slot. The two slots ofdell/riser-3a-14g@2carryrotate: 180. A bay that is not turned states nothing, as before. Additive; thecontractnumber does not move.- DCIM exports: a micro-USB console reaches the device type as a console port,
Console (Micro-USB), typeusb-micro-b, beside the RJ45Consolethe panel labels apart from it; and an RJ45 AUX serial port on a chassis is a console port namedAUX, as a card's already was. 96 device types in each oflibrary/exports/netboxandnautobotgain ports (31 devices with a micro-USB console, plus the ASR 9001, ASR 9901 and MX80 with AUX), and nothing already exported is renamed, retyped or removed. A USB storage or service port is still not exported, by the existing rule that a USB data port is not a console; every management-cluster port that is not exported is now named, with its reason, inMGMT_NOT_A_DCIM_PORT, and a test asks the exporter about each one (#384). edgecore/eps1222.0.8 draws the orange bands that mark its 90 W ports 41-48: one behind the legend row above them and one behind the lamp row below, measured on the guide's front elevation at its native resolution and coloured from a pixel count. The single band it carried sat at x 601.74 on a 440 mm face, so it was never seen. The panel legend is transcribed as "1.65A Max/Port41-48", not 1.85 A, and the row under the ports is identified as the per-port lamp row (#878).juniper/mx2044.0.2 no longer carries four ear-flange rects beside its front and rear faces. They lay wholly outside the drawing and were never seen, and the device's own provenance says the ears are not modelled (#878).edgecore/exp800-16oandedgecore/exp100-32x(2.0.0) print the white arrow beside each port numeral as silkscreen (silk-arrow-N), as the AIS800 review ruled for the same glyph, and keep the dark triangular windows under it as lamps: the EXP800 quick start calls them out as the OSFP LEDs (#396). Both port strips were re-measured on their elevations: the numerals, which sat where the arrows are or past the windows, and the lamps, which sat between the two pairs of windows, now stand where the drawings put them; each lamp is its port's left window.- The covers of the FS HD and UHD finger ducts show their four latches in 3D
(#869): the plate and its clips are one raised group, so the clips are
drawn on the face instead of left behind it, and the hinge rails end 0.1 mm
behind the face.
fs/cmh-uhd-sfdabs1u-cover,-2u-cover,-3u-cover,fs/cmh-hd-sfdabs3u-coverand-4u-cover1.0.1; the five devices 0.1.1. The 2D drawings are unchanged. fs/cmh-sfds1ucites the FS quick start guide it takes its fixings from as a reference, and its capacity note and those offs/cmh-sfds2u,fs/cmh-dfds1uandfs/cmh-dfds2uno longer label a missing figuredatasheet(#869).- Four FS finger-duct covers reserve a
logo-zonewhere FS prints its mark (#869), so a renderer has the box without the library drawing a vendor logo. Measured on FS's straight-on renders forfs/cmh-sfds1u-coverandfs/cmh-dfds2u-cover, estimated from an angled close-up forfs/cmh-sfd1u-cover, and borrowed from the SFDS1U forfs/cmh-bs-sfds1u-cover, of which no image exists; all four 1.1.0.fs/cmh-sfds2u-coverandfs/cmh-dfds1u-coverclaimed a mark that no render or drawing shows; their provenance now says so, 1.0.1. The devices cmh-sfds1u, cmh-sfds2u and cmh-bs-sfds1u 0.1.1, cmh-dfds1u, cmh-dfds2u and cmh-dfd1u 0.1.2, cmh-sfd1u 0.1.3. The 2D drawings are unchanged. fs/cmh-sfd1u0.1.2: the back of the base is built inside the 87 mm envelope. 0.1.1 built its five rear plates 11.3 mm outward from the rear face, so in 3D the duct was 98.3 mm deep with an air gap behind the well floor; the plates and the base's side walls are now sunk just inside the faces. The 2D views and the DCIM exports are unchanged apart from the version.devicelockno longer calls a change minor because it added an id while something already there moved: the added placements are taken back out and the rest must still hash to the old shape, or the change is a major (#828).- The faces of the HPE FlexibleLOM adapters are read from their own
photographs (#764).
hpe/flom-817721-b21@1, the 535FLR-T, was a copy of the 562FLR-T face: its P2 legend is between the jacks and it has no right vent field. The 640FLR-SFP28 has its features 1.0 mm further right, with ACT lamps that show activity only and LNK lamps that show link only. - The IEC inlets' cavities are as deep as the cord ends that enter them.
std/c14-inlet@1(1.4.0) is 17.0 deep, shroud face to cavity floor, with its pins rising 15.0, both dimensioned on Adam Tech drawing S00087C rev D, where it was 13.0 and 12.2 estimated.std/c20-inlet@1(1.4.0) is 19.0 deep with 17.0 pins, still estimated (the C19 nose less 1, as the C13/C14 pair stands; no held drawing sections a C20 cavity), where it was 15.0. The cord ends seated in them,generic/c13-plug@1andgeneric/c19-plug@1(1.1.0), stand 4.0 less proud: 47.0 and 57.0 in front of the inlet face. The 126 devices whose supplies or chassis carry one of these inlets take a patch (97 C14, 30 C20,dell/r740xdboth); their DCIM exports change in the drawing version line only (#793). common/rj11-jack@1(1.2.0) is drawn as the six-position jack it is: the opening is 9.88 wide (TE C-1775675 rev C) in three tiers (body, latch shoulder, latch slot) recessed into a solid housing, asstd/rj45@2draws its own, where it was the 11.6 RJ45 width; two contacts are loaded (6P2C); and it is 20.57 deep with a built cavity, where it stated no depth. Its body is unchanged; itsmateandtelpoints move from (7.0, 6.75) and (7.0, 6.7) to (7.0, 4.925), the centre of the 9.88 x 6.85 body tier, so a seatedgeneric/rj11-plug@1(1.0.1, provenance only) sits centred in the tier and clears the opening by about 0.12 a side, where at the old point it stood 1.8 off it. Nothing on a device addresses either point, sohalny/hlx-tgvtakes a patch (#837).dcim_exportrefuses a listing name pattern that does not parse, by name, where it raised a bareSyntaxError(#719).- The 3D viewer survives a lost WebGL context (#746). The view went blank with no message and never came back. The viewer now lets the browser restore the context, then rebuilds the loaded device or component with its configuration, overrides, states, pulled parts, selection and marks, and leaves the camera where it was. While the context is lost the explorer says that 3D is paused, and when the browser refuses a new context it says to reload the page or close other tabs with 3D open.
- Lint L109 judges a declared
optical.polarityagainst the pattern for the trunk connector's own fibre count, read from itsoptical.positionsas L80 reads it, and compares only the ports actually wired (#524). It used to count the paths, so an MTP-24 Type AF cassette with fibres declaredunused, or wired to twelve ports, was judged as a narrower connector: its correct row-exchanged paths failed and the plain pair swap passed. A module whose trunk is stated inoptical.trunk(#246) is now judged too; it used to be skipped without a word. - L39 centres a part's composed opening on its cutout, not the part's whole
footprint (#248).
common/qsfp28-cage@3carries the chassis lamp band above the cage, so itsstd/qsfp-ganged@1opening sits 4.2 mm below its top edge; the TE 2322551-4 drawing has the cage itself centred on that opening. Every correctly punched AS7726-32X port, and its USB beside a printed symbol, read as 1.5 to 1.74 mm off. The 33 baselined warnings are gone and no component or device changed. - L46 measures what composed parts draw, not their boxes (#684). A pair whose
boxes collide is measured again on each part's skin shapes (rects, circles,
ellipses, polygons, text; a skin with a path or a transformed group counts as
its whole box), so the open middle of
common/qsfp-pull-tab@2andcommon/qsfp-dd-pull-tab-type2@1no longer reads as covering the bores and inserts it frames. Seven baselined warnings are gone, and the provenance sentences that explained them are removed fromgeneric/qsfp-lc@22.2.2,generic/qsfp-dd-lc@22.2.1,generic/qsfp-lc-simplex@11.0.1,generic/qsfp-mpo@11.0.1 andgeneric/qsfp-dd-mpo16@11.0.1. - Vendor marks are reserved, not drawn or boxed, on fifteen devices and one
component (#964). No DCIM export changes and nothing is renamed.
- Edgecore:
edgecore/dcs2401.1.9 drops the greybrand-badgebox that stood for the logotype and reserves its measured box as the regionlogo-zone;edgecore/dcs5112.0.9,edgecore/eps1212.0.8 andedgecore/eps1222.0.9 gain the region where the logotype sits. - FS blanking panels:
fs/fhu-bps-1u-10,fhu-bps-2u,fhu-bps-4u,fhu-bpstl-1u-10,fhu-bpstl-2u,fhu-bpstl-4uandfhu-bpa-1u-10(each 0.1.1) gain alogo-zoneregion at the mark measured on the straight-on render;fs/fhu-bpad-2uandfs/fhu-bpad-4u0.1.1 gain one region per unit,logo-zone-1upward, inside the recess each unit already draws. - Casa:
casa/chassis-label@11.4.0 no longer draws a black triangle where the vendor mark sits; the skin nodelogois gone and the measured box is the elementlogo-zone, left empty.casa/c100g1.0.2 andcasa/c40g0.5.20 take the patch for the part they place.
- Edgecore:
- A card's USB jack is a console port only when its placement says so, as on a
device. The module export filed every
std/usb-apart as ausb-aconsole from the ref alone, and had no micro-USB or USB-C console row; it now asks the device path's own decision (device_console_row): a USB-A or USB-C jack needsrole: console, and a micro-USB jack is a console when its id, role or function says so. The USB storage and service ports on 14 Cisco ASR 9000 RSP/RP cards, 10 Juniper RE/RCB cards and the two Dell 16G rear I/O boards no longer export as consoles; eight CommScope CH3000 modules gain their micro-USB console (usb-micro-b), and the Eaton G4 ENMC its USB-C console. BREAKING for DCIM data already imported. - The CommScope CX3003C and CX3033N (1.0.1; CH3000 3.2.4) no longer call their micro-USB a console: both datasheets reserve it, with the RS-232 jack beside it, for factory use, so it exports nothing.
- The MX chassis state the power their vendor publishes (#113).
power-typical-won the MX80 (310 W, output side, Tables 14 and 20), MX240 (1860 W), MX480 (3470 W) and MX960 (6520 W) - the last three from the family datasheet with the DC figure inpower-typical-scopeandpower-envelope: unstated- and on the MX10004 (7.5 kW), MX10008 (12 kW) and MX10016 (23 kW), typical and fully loaded per their datasheets.power-max-ac-w600 andpower-max-dc-w625 on the MX104 (input side, Table 6); 1520 W typical and 4420 W at 55 C on the MX2008 for the base system only (power-envelope: bare); the MX10003'stypical-draw-wis nowpower-typical-w1676 besidepower-max-w2110 (Tables 24 and 25). Provisioning ceilings go underthermal.max-thermal-output, flagged as ceilings (MX80, MX480, MX960). The MX2010 and MX2020 carry no figure: their guides contradict themselves, recorded as asources-disagreegap scoped to both power facts. Five records that called the vendor silent or the tables unextracted are corrected (MX80, MX104, MX960, MX10004, MX10008). Each device is a patch version; the DCIM device-type exports change only in their comments. - Nautobot: the MX2000 line-card adapter (
MX2000-LC-ADAPTER) exports itsmpcbay, so an MPC can be installed in it in an MX2008, MX2010 or MX2020 slot (#917). The bay has a blank position: Nautobot skips a blank position when it names ports, so an MPC in the adapter infpc3names its portsfpc3/port-0-0, the names the same MPC takes in an MX960'sfpc3. NetBox is unchanged and still saysfpc3/mpc/port-0-0. A carrier's only bay that accepts a module also seated directly in a chassis bay is given this way; the adapter is the only one at 0.2.0. - Nautobot: the MICs that only an MPC takes (
MIC-3D-4XGE-XFPand the fourMIC3-3D-*) name their ports{module.parent}/{module}/xagain, as before #261 made the adapter count as a second depth for every MPC. BREAKING for DCIM data already imported from an export taken since #261 merged: those five module types need re-importing. Their bays on the MPC1E, MPC2E and MPC3E are still withheld from Nautobot (nautobot/nautobot#5823), as in an MX240, MX480 or MX960. This is where the three Nautobot entries of this section end up (#765, #261 and this one). Against an export taken at 0.1.0, those five types move from{module}/xto{module.parent}/{module}/x, once. OnMIC-3D-4XGE-XFPthe third and fourth ports are also renamed, in NetBox as in Nautobot:port-0-2andport-0-3areport-1-0andport-1-1(#887, under Changed). juniper/mx4805.0.1: the weight comes from the hardware guide's Table 88, 29.7 kg for the chassis with midplane, fan tray, air filter and cable management brackets and 100.26 kg for the maximum configuration (weight-base-kg,weight-max-kg). The "up to 163.5 kg" it carried was the guide's rack text, 163.5 lb (74.2 kg), read as kilograms; the falseweight-and-max-configgap is gone (#886).- The 300CB08-C, 300CB08-SC and the four nrg300CB08 connectorized panels
(1.1.2) no longer list an
output-pluggap: their P40 receptacles are connector slots andamphenol-ns/p40-plug@1seats in them. Their DCIM exports change in the drawing version line and the gaps comment only. - The 3D front of
nokia/lmfs-f's front-cover configuration was laid out on the 528 mm drawing rather than its 481 mm face, so every part sat 23.5 mm left of where it is and the face was textured over a plate 528 wide (#865). - The snap-in ring's relief agrees with its guide: each leg was built 6.8 mm thick in the plane of the loop, which narrowed the drawn opening to 30.0 mm against the guide's 32.0 and stood a route's sill point 1 mm inside the rear leg. The legs are 5.8, as the plan's 43.6 less the opening gives and the ring-profile view reads to a pixel. The slit, re-read, is 2.2 mm where 3.8 had been read, in the relief and in fs/fhd-cmp5dr-profile@1 1.0.1's side view.
- L50 no longer reports printing as painted over by a node that is never on screen with it: a position's other option, drawn after it (#808).
- The craft interface bays of
juniper/mx960(1.1.0),mx2008,mx2010andmx2020(0.3.0) statefor: chassis, and theircraftgroup's role ismanagement, as it already was on the MX240 and MX480: the craft interface is where an operator reads and acts on the router's state, with LEDs for its components, buttons and an alarm cut-off.dell/r660(5.1.0) does the same for its left control panel, which the R660 Installation and Service Manual describes as holding the system health, system ID and status lamps (#414). - In 3D, a part whose only SHOW node is hidden by default now rebuilds when
that node should appear: each part group records its position fields as
data-position-fieldsbefore hidden nodes are removed, and the viewer's rebuild check reads it (#874). - A
data-moveentry whose number is not one (.,1.2.3) is refused by the kit as the build refuses it, instead of writingNaN(#874). - The 3D viewer draws a part's fields on its first scene.
setFieldscalled before the firstload- a host handing over a link's latch colour as it creates the viewer - was kept and never painted: the latch came up grey, and the same map again changed nothing.build()now loads the fields beside the lamp states and pulled parts, before any face is cut (#850).
What 0.1.0 promises, as docs/format-stability.md states it in full:
- Manifests are
format: 1, which schema v1 names. The schemas were labelledv0until this release, which was the same format under a second name. Each schema's$idishttps://portrayal.dev/schemas/v1/<name>.schema.json(device,component,listing), and the schemas are published there. - The published build is
contract: 2. The history below says what1and2each changed. - At 0.x the tools read the current format only. Every change that raises
formatorcontract, or re-files DCIM data already imported, is listed here, with what to change to move across, and it raises the package's minor version. - At 0.x a superseded component major may be removed. Every removal is listed here with the ref that replaces it. From 1.0 a retired major is deprecated for at least one release before it is removed.
- Lint codes are never renumbered or reused, because a manifest waives a rule by its code. A deleted rule's code is retired, not reissued.
- From 1.0, a change that raises
formatorcontractis a major version, and the previous format stays readable for one release.
Everything below changed before the first release, while every consumer was
inside this repository. It is kept because the build already carried contract
numbers through it, and because it is the record of what each major and each
breaking export change replaced.
One of these changes is one the promise above now rules out: during
pre-release the power rules were renumbered from L117-L119 to L118-L120
(commit 5f6417b7, #513), because another branch had taken
L117 first. The move was made on the power rules' own branch, before they
merged, so no code on main ever named a power rule at L117-L119, but anything
written against that branch's numbers names a different rule. From 0.1.0 a
code is never moved; the lint catalogue test pins every code issued.
- ArcOS listings for the Arrcus HCL (#674). Every box on
the Arrcus Hardware Compatibility List (June 2026, ArcOS 8.5) that the library
models - 29 of the 30 from UfiSpace and Edgecore - is listed under
arrcus/, with the HCL row as its source and Arrcus's own grouping (Switching (XGS), Routing (DNX), VDR line and fabric cards) as its portfolio. The AS7726-32X and AS7326-56X carry ArcOS port names from live units; the other 27 carry anarcos-port-namesgap instead, because ArcOS's own documentation disagrees on whether a platform's first port isswp0orswp1. Listings may now carrygaps. - Listings (#674). A NOS vendor lists the hardware it
supports:
library/devices/<nos vendor>/<id>/listing.yamlpoints at one device and carries only what the NOS vendor changes - interface names, its own model name and catalogue family, and its own part numbers where it has them. This is how NetBox and Nautobot file a disaggregated box: one device type per manufacturer that sells it, with one copy of the metal behind them all.listings.json: every listing, whole, keyed<ns>/<id>, withnsand the resolvedmanufactureradded.devices.json: each device carrieslistings, the keys of the listings that list it, and itssearchblob gains each listing's vendor, NOS and names, so "arrcus" or "ocnos" finds the hardware.devices.lock.json: alistingsmap besidedevices. A listing is versioned (listing.lock.jsonbeside it): a changed port name, model or part number is major, an added configuration override minor, wording a patch.vendors.json: IP Infusion (OcNOS), DriveNets (DNOS) and SONiC join Arrcus as software vendors.- Lint L124: under one NOS vendor, no two listings export the same DCIM model,
and an alias names one listing unless each claimant marks it
shared.
- Lint L123, library-wide: one module, one bay size. Every bay that accepts a module, in any device or carrier, reserves the same size for it to within a millimetre, compared in the module's own frame so a turned bay matches an upright one. A warning; four remain - the A99-RP-F between the ASR 9902 and 9903, and three outside Cisco.
presentson acomponents.jsonentry for a part that mates into something: what it offers the next tier when it is itself seated -interface,mateandliftin its own frame (the point a boot or a plug stands on, and that point'sout),accepts,kind,rotate,boresanddefault, in a slot entry's shape. A generic LC or RJ45 plug presents its boot point, and a single-bore optic its one bore. A consumer seating through slots can now seat the chained tier the build seats under<key>-occupant: carrymatethrough the seat's placement, take its turn, and add its lift to the lift of the slot it sits in. Omitted for a part that presents nothing, and for one whose presented interface nothing in the library mates (#611).data-rear-rotateon a rear cutout a turned bay is seen through: how far a back drawn in it is turned, the bay's ownrotatenegated (a clockwise turn seen from the front reads anticlockwise from behind). The back's projection in that hole carries the same turn about its own centre, anddata-rear-atis then its unturned top-left, as a placement'satis. Unturned holes are unchanged.- Component groups: a component declares
groups:in the device shape and a part joins one withgroup:. A port on a module seated in a bay, at any depth, now carriesdata-group,data-group-roleand its group's attrs and description, with the part's own attrs winning. A cage on such a card publishes the group's side asoccupant-attrs, and the build writes the same attrs on an optic seated there.components.jsoncarries each part'sgroupand the component'sgroups, and module-type exports type a card port from its group's attrs and mark amanagementgroup's portsmgmt_only. A component group's role takes the device group's six values,fabricincluded, and L110 reads a component group'sspeedas it reads a device group's (#511). data-inner="1"on the inner part of a composed port, thestd/*core thatcommon/rj45-eth@1,common/qsfp28-cage@3,common/sfp-plus-cage@2andcommon/rj45-ganged-eth@1draw as a nesteddata-class="port"element. The core keeps its class. An audit that counts ports should skip it with[data-class=port]:not([data-inner])(#511). The same mark covers a port component that draws a secondclass: portelement inside its own skin, not only one composed as a separate part.- Every
configs[]entry in<device>.configs.jsoncarriesairflow—front-to-back,back-to-front,sideorpassive, ornullwhere the device states none — resolved the way each drawing'sdata-airflowis (the configuration's value, else the chassis's). Thechassisblock carries the chassis's ownairflow. A page filtering builds by airflow no longer parses it out of a configuration's name or description (#513). - A device states its supply feed as
power-ac,dcorhvdc- on the chassis where the box has one feed, and on a configuration where its build differs, the wayairflowis stated (lint L118). Everyconfigs[]entry in<device>.configs.jsoncarries the resolved answer aspower, always a list (["ac"];["ac", "dc"]for a build fed both ways;[]where nothing is stated), and each drawing's SVG root carries it asdata-power, space-separated. Thechassisblock carries the chassis's ownpower. optionsin<device>.configs.jsonand on every entry ofdevices.json:{"power": [...], "airflow": [...]}, the union over a device's orderable and base builds. "Does this come in DC?" and "is there a back-to-front build?" are one lookup; anexampleormodelbuild does not widen it, and a build the vendor sells that nobody has modelled is not in it.comparable-facts.jsonreadsairflowfromchassis.airflowand the configurations before any attrs prose (it read only attrs, so a device stating airflow properly compared as silent), and gainspower-feed.- All 84 Edgecore, UfiSpace and Celestica devices state
poweron every build. There were 85 when this landed, and the one without was the N3100-4C, a PCIe card fed by its host slot; it has since become a module (below), so the census has no exception. Four more stateairflow(AS7946-30XB and AS7946-74XKSB front-to-back, S9511-20CT front-to-back, S9502-12SM passive). Lint L119 asks any other device with supplies for a feed, as a warning baselined for the 32 that do not say yet; L120 reports a build whosepowercontradicts the supply it seats (#513). - Back-to-front builds (
ac-b2f,dc-b2f) on the UfiSpace S9300-32D, S9301-32D, S9301-32DB, S9311-64D and S6301-56ST, which each sold both directions but modelled only front-to-back. They seat the intake supplies and fans with blue latches, handles and "I" airflow tags, coloured from the vendor's back-to-front renders. The parts gained what that needs:latch-finish/latch-edgeonufispace/psu-132-ac,psu-132-dc,psu-151-ac,psu-151-dc,psu-242-acandpsu-242-dc;handle-finishonufispace/fan-402825; and anintakeskin onufispace/fan-405637,fan-402825andfan-805616. Each part took a minor bump. The S9110-32X's existing back-to-front builds now use theintakeskin too; they wore the red "E" tag. - DC builds on the Edgecore COR550 (
dc-f2b, 7926-40XKFB-O-48V-F) and CSR440 (dc, AS7535-28XB-O-48V-F V2) and the UfiSpace S9620-32E (dc, PSU-322-DEJR-NN), and an AC build on the S9502-12SM (ac). No held document shows those supply faces, so each is drawn with the other feed's part and says so in its gap. Lint L120 is baselined for the three DC stand-ins, as for the COR580. - Every device in
library/dist/devices.lock.jsoncarriesplacement-attrs: a digest of theattrseach placed port states for itself (speed,media,usb). Retyping one now asks for a patch bump, where before it asked for nothing (found on #519). - Every device in
library/dist/devices.lock.jsoncarriesplacement-geometry,placement-addressingandplacement-surface, fingerprinting the placement and bay keys that were hashed nowhere:inset,lift,in,under,only-in,optionalandinterfaces(a major);forandrel-pos(a major when changed or removed, a minor for aforstated where there was none, nothing for a newrel-pos- recorded as a map, not a digest, so the cases can be told apart);states,description,provenance,physical-contextandframes(a patch). Editing any of them used to ask for no bump at all. - The same three keys now cover the keys only a bay states:
opening,floor,planandrearinplacement-geometry(a major), andinterfaceinplacement-addressing(a major when changed or removed, a minor when stated where there was none). The eight devices whose bays state one - six Cisco ASR 9000s, the R740xd and the FHD 1U enclosure - were re-locked, and only theirplacement-geometrymoved. No device version changed (#537). devices.jsoncarriescontract: 1— the first version a consumer can check (#185).library/dist/devices.lock.json: every device's fingerprint in one file, assembled from the per-device locks (#182).- Module types export SONET rates (
sonet-oc3,-oc12,-oc48,-oc192) for the 27 SONET, ATM and channelized cards that had been exporting as Gigabit Ethernet (#296), and CFP/CFP2/CXP at 100G for fourteen Juniper cards that exported nothing (#254). - Device types carry
power-portswhere the chassis holds the inlet, and RF and timing jacks asotherinterfaces with their connector or function as a label (#286, #285). <device>.configs.jsonand everydevices.jsonentry carryaliases: the other names the box is sold or listed under - an AS number, a marketing name, a DriveNets name - as a list of strings,[]when there are none.modelstays the canonical name and is never repeated there. The names are also in thedevices.jsonsearch field, so a hardware compatibility list's AS9716-32D findsdcs510(#514).components.jsoncarries each part'soptical.ends: for every fibre endpoint,{to: string | string[], label: string | null}, keyedpart.non the front andrear:part.non the rear; a fan-out endpoint (a splitter's common port) has a listto, one entry per branch. A rear cutout a bay is seen through now also carriesdata-rear-ref(the seated occupant),data-groupanddata-group-role(the bay's own group), anddata-rel-pos(its position within it) - so[data-group='slots'], or any group selector, now also matches these rear holes on a rear view, not only the fronts they used to match alone; a consumer counting bays should key off[data-class=bay]instead, and a document already selecting by group will now also hit the rear cutouts. In the explorer, a fibre's row says where it goes, selecting a fibre marks its far end on every loaded face, and a rear row reads as the slot it is, not the panel hole (#535).- Connector slots. A placement presenting a connector interface -
lc,lc-duplex,scormpo, the new registry inspec/schemas/connectors.yaml- is now published where cages are: in each view'scages[]in<device>.configs.jsonand in each component's owncagesincomponents.json, as an entry withkind: connectorandmedia: null. Itsacceptsis every part whosemates:is the slot's interface, dust caps and plugs alike. Every entry, cage or connector, now carrieskind(cageorconnector),default(the ref the slot ships holding, ornull) andbores(the ids of the slots a connector seated here takes the place of,[]where it spans nothing:["1", "2"]on a duplex LC adapter). A cage entry is otherwise unchanged; a reader that wants cages only filters onkind: cage. A configuration'soccupants:now keys a slot at any depth, with everymodulestep left out (bay-1/lc01/1, a bore of an adapter on a cassette in a bay), and lint L114, L115 and L116 hold the shipped default, the exclusion between a duplex slot and its two bores, and the duplex geometry. - Every LC, SC and MPO port that ships capped now DRAWS ITS DUST CAP AS AN
OCCUPANT: a group with
data-behaviour="occupies",data-fornaming the slot and the id<slot>-occupant(port-1510/1-occupant), seated in every configuration that does not key the slot. The caps arecommon/lc-dust-cap@1(each bore of the Smartopticscommon/lc-duplex-adapter@6, 72 on a DCP-R-34D-CS front),common/lc-duplex-dust-cap@2(the FS stacked adapter's own slot),common/sc-dust-cap@1(each opening ofcommon/sc-duplex-adapter@5) andcommon/mpo-dust-cap@2(the FHD cassette rears' MPO bulkheads); the shuttered adapter ships none. AN AUDIT COUNTING OCCUPIED PORTS BYdata-for/data-behaviour="occupies"NOW COUNTS CAPS: a capped port is occupied, by its cap.configs[].occupantsstill lists only what a configuration keys, and a slot's shipped cap is itsdefault. - New parts: the plugs
generic/lc-duplex-plug@2,generic/sc-plug@1,generic/mpo12-plug@1andgeneric/mpo24-plug@1, which a connector slot offers beside its cap, andstd/lc-bulkhead-bore@1, the panel adapter's keyed aperture, whose keyway runs 5.71 from the ferrule where the transceiver receptaclestd/lc-bore@3stops short. - The explorer swaps connector slots as it swaps cages - a cap, a plug or
empty, one level of a duplex slot or the other - on a cassette's rear face
as well as its front, and in 3D each seated cap and plug is its own part
that pulls out. A device's lock now follows the components a module draws
on its other
faces:, so a change to a cassette's rear asks for a bump where it used to ask for nothing. - A pluggable that
conforms:to a module envelope declareshead:, the box it occupies OUTSIDE its cage (contract key, plus the matching registry envelope onsfp-module,qsfp-moduleandqsfp-dd-module), and aheadthat exceeds its registry envelope may say so withexceeds:and a source. Lint L121 checks it.components.jsoncarries a part'shead, verbatim from its contract. See pluggables-heads-design.md. generic/sfp-rj45@1, the copper SFP generic, composingstd/rj45-ganged@2in its head so a plug and boot can seat in it.common/qsfp-pull-tab@2: a real U-loop tab (two arms and a grip, measured off photographs and QSFP-DD HW 6.3 Appendix B) in place of the@1solid brick, composed again by the QSFP generics.generic/qsfp-lc@2andgeneric/qsfp-dd-lc@2, composingcommon/qsfp-pull-tab@2and declaringhead:.- A composed part now takes a field value from its host at build time when
both declare the same field key (
render.py'sfill_from_attrs); a part's ownparts:entryattrsstill win. - Lint L73 counts a field as used when a composed part declares the same key as its host, matching the build-time rule above.
- Lint L76 (RJ45 jack lamps) skips a contract whose class is
transceiver: a copper SFP's jack carries no link LEDs, so it is not asked for one. - Cable ends:
generic/sfp-cable@1,generic/qsfp-cable@1,generic/qsfp-dd-cable@1(Type 1, at the MSA maximum) andgeneric/qsfp-dd-cable-type2@1. Each is a module in the cage and a head, pull strap, strain relief and a short straight stub of cable outside it. Thecableconnection point sits at the stub's far end, so a downstream tool continues the run from there. The cage accept lists offer them beside the optics. See pluggables-cables-design.md. - Vendor cable ends wrapping those generics, each with
cable-kind(dac,acc,aecoraoc) and its own document's values:molex/sfp-plus-passive-dac,amphenol/qsfp28-passive-dac,amphenol/qsfp56-linear-active,fs/qsfp28-aoc,siemon/qsfp28-aoc,volex/qsfp-dd-passive-dacandcredo/hiwire-shift-qsfp-dd, and the vendorsmolex,amphenol,volex,credoandsiemon. - A
cable-odfield (mm) on the cable ends, and a skin bindingdata-r-from="<field>"that sets a circle's radius to half a numeric field value, at build time and in the kit at runtime. Empty or absent leaves the drawn radius. Lint L122 keeps acable-od(a field default or a composing part's attrs) between 2 and 15, and accepts only the plain decimal number the build and the kit read. Lint L73 countsdata-r-fromas wiring a field. - A
cableconnection point may sitonacylrelief feature; it leaves from the cylinder's far end (lift+cyl), in the build and in the kit. - Six coax interfaces -
f-type,bnc,sma,smb,mcxanddin-1-0-2-3(spelled with hyphens; the schema's interface/mates pattern refuses a dot) - each citing its standard, so every existing coax port publishes akind: connectorslot alongside its cage. Two new jacks:std/bnc@1andstd/din-1-0-2-3@1(cores), composed by the bezelscommon/bnc-jack@1andcommon/din-1-0-2-3-jack@1, following the existing SMA/SMB core-plus-bezel pattern. Six generic plugs, one per interface -generic/f-type-plug@1,generic/bnc-plug@1,generic/sma-plug@1,generic/smb-plug@1,generic/mcx-plug@1andgeneric/din-1-0-2-3-plug@1- each a coupling part, a crimp ferrule and strain relief, and a 30 mm cable stub sized by acable-odfield. Aseat-outconnection-point key: a number of mm a part seated at that point stands off, absolute from the part's own face, where no drawn feature's rear already sits at that plane; mutually exclusive withon:and read only on the presented point (interface-at, defaultmate;manifest._seat_out). Lint L106 refuses a point that carries both, aseat-outthat is not a number at or above 0, and aseat-outon any other point. The kit now labels the coax media (BNC, 1.0/2.3, F, MCX) in its port rows. See connectors-coax-design.md (#650).
-
juniper/mic-3d-8ds3-e3andmic-3d-8ds3-e3-v(1.1.2): their 16 jacks stateimpedance: 75, and the description no longer calls 75-ohm mini-SMB an unmodelled interface. Mini-SMB is the 75-ohm SMB series, the SMB interface and intermateable with 50-ohm SMB, so the jacks were correctly SMB (#672). The MX80, MX240, MX480, MX960, MX2008, MX2010 and MX2020 take a patch for the composed card. -
common/qsfp-pull-tab@2(2.2.0) models the strap's S-bend: each arm is six relief boxes along the reach (arm-l, thenarm-l-2toarm-l-6, and the same on the right) that follow the side-view curve, down 1.5 into a dip about 31 from the nose front and back up to the grip, meeting end to end. The tab's vertical figures were read again on fitted body edges: the grip top is 1.23 above the module top (was 1.07) and the strap top 0.47 (was 0.57), so the size is 19 x 8.56 and the risers end 7.33 below the module top, where they were measured.generic/qsfp-lc@2andgeneric/qsfp-dd-lc@2(2.2.0) compose the tab atat: [-0.325, -1.23]. The face-on drawing is unchanged apart from that 0.16 shift. No device seats these parts, so no lock moved (#647, #685). -
std/c20-inlet(1.3.1) lays all three blades along the long side of the recess, as IEC 60320 C19/C20 has them and the SCHURTER C20 front view it cites draws them: line and neutral 13.0 apart, earth 8.0 off their line, in a 29.0 x 21.0 recess. It had drawn them across the long side. Ids, size and connection point are unchanged; the 27 devices that seat it take a patch. -
generic/qsfp-lc@2(2.1.0) draws its nose at the height the maintainer's photographs of a QSFP SR4 module show: 1.4 above and 1.4 below the 8.5 body, 11.3 tall, soheadisat: [0, -1.4],h: 11.3incomponents.json, and thebodyoutline and its 20 mm solid grow to match.common/qsfp-pull-tab@2(2.1.0) gainsriser-landriser-r, the posts at the arm roots (7.5 out from the nose front, 7.8 tall from the strap top), and its size grows from 19 x 3.4 to 19 x 8.3.generic/qsfp-dd-lc@2(2.1.0) wears the risers through the tab; its head is unchanged, since no QSFP-DD module has been measured. Ids, connection points and placements are unchanged, and no device seats these parts, so no lock moved (#646). -
In 3D, a solid painted from a field now takes its side colour from the field: the QSFP cable end's strap, ring and stub (so a wrapper's green or blue strap and the Siemon AOC's aqua jacket show on every face), every coax plug's cable stub, and the DCS201 and DCS240 fan handles. Their relief features stated a literal
color, which the kit never overrides; the parts take a patch, and the DCS201, DCS202, DCS240 and DCS511 a patch for the fans. Lint L73 now refuses a reliefcoloron a node a field paints (#643). -
Lint L122 now also reads a
cable-oda device sets on a placement (a cable end placedmate-toa jack or cage), with the same number and range check as a wrapper's (#644). -
siemon/qsfp28-aoc(1.1.1) draws its pull tabs black (latch-color: #090502), read off the product photograph the aqua jacket came from, in place of the generic's neutral grey (#645). -
contract: 2. A drawing no longer embeds the device's source manifest. Every face carried the same whole manifest in its<metadata>: 139 MB of a 249 MB build, 107 KB in each of the R740xd's 252 faces. It is now published once per device as<device>.source.json, and thesourcekey in a face's metadata is replaced bysource-sha256, the digest of that file's exact bytes. A reader that took the manifest from any drawing reads the one file instead. What is published is unchanged; only where (#665). -
Each distinct drawing is written once. Configurations that differ only in a part a face cannot see draw that face identically, and each wrote its own copy: the R740xd's 42 configurations wrote 252 faces holding 35 distinct drawings. A drawing is now written once, named after the first configuration (in manifest order) that draws it, and
configs[].filesin<device>.configs.jsonmaps each configuration's faces to their files. Find a face throughfiles;<device>.<config>.<view>.svgexists only for the configuration that names it. A face no longer carries its configuration's name:data-configon the root andconfigin<metadata>are gone, since a shared drawing belongs to several. The default configuration's<device>.<view>.svgcopies are unchanged (#665). -
Also in
contract: 2:overlays.jsonis gone;listings.jsonreplaces it (#674). The NOS naming an overlay carried under the hardware (devices/edgecore/as7726-32x/overlays/arcos.yaml) now lives in the NOS vendor's listing (devices/arrcus/as7726-32x/listing.yaml), and the overlay'sidentity:block is retired - the listing's namespace is the vendor. Lint L56 now checks a listing: it lives under a software vendor and names only configurations, ports and components its hardware has. -
BREAKING for DCIM data already imported. The Arrcus device types are renamed from
Arrcus/ArcOS on <SKU>toArrcus/<SKU>- the hardware's SKU, under the NOS vendor, as NetBox's and Nautobot's own libraries file a disaggregated box - and they now carry the hardware's part number, which the identity export dropped. The metal is the same metal and its part number still orders it; a listing that publishes its own replaces it per configuration.dcim_export.py --nosis removed: every listing exports. -
BREAKING for DCIM data already imported. A module type names its ports per bay. Every interface, console, power, front and rear port name on a card starts with
{module}/, which NetBox and Nautobot both fill with the position of the bay the card is installed in, and a device type's baypositionis now the bay's whole id (slot-1,psu-2,fan-1) where it was the trailing number (1,2,1). A DCP-404 in the DCP-2'sslot-1installs its client port asslot-1/c1: the drawing's path to that port (slot-1/module/c1) with/module/taken out. Before this, two identical cards in one chassis both madec1, and since a port name is unique on its device the second install was refused; and 167 of the 205 bayed device types put two bays at one position (Fan 1, PSU 1 and slot-1 all at1), so the token alone would not have been enough. The fibre maps name ports the same way.Re-importing the types does not update what a DCIM has already made from them. A DEVICE created before this keeps its old bay positions, because both DCIMs copy a device type's module bays onto the device when it is created: a card installed afterwards into that device's
slot-1resolves to1/c1, notslot-1/c1, which still does not match the drawing, and it can still collide wherever Fan 1, PSU 1 and slot-1 all sit at1. On an existing device, edit each module bay's position to the bay's id (thepositionin the device type) before installing cards. A MODULE installed before this keeps its old port names until it is removed and installed again. -
THE ASR 9000 CARD STANDARD. Every full-size ASR 9000 card and every bay that takes one is 41.4 x 395.7 mm, with a 355.6 mm
opening, so a card seats and draws the same in each chassis that accepts it. RSPs and RPs are no longer drawn larger than the line cards beside them (the RSP-880 was 46.0 x 428.5, 32.8 mm past its slot on the ASR 9006). Majors, each a new directory with the old one removed, for the 48 cards whose size changed:cisco/a99-10x400ge-x-se,cisco/a99-10x400ge-x-tr,cisco/a99-4hg-flex-se,cisco/a99-4hg-flex-tr,cisco/a99-rp3-se,cisco/a99-rp3-tr,cisco/a99-rsp-se,cisco/a9k-16t-8-b,cisco/a9k-24x10ge-se,cisco/a9k-2x100ge-se,cisco/a9k-36x10ge-se,cisco/a9k-400g-dwdm-tr,cisco/a9k-40ge-b,cisco/a9k-40ge-e,cisco/a9k-40ge-l,cisco/a9k-4hg-flex-se,cisco/a9k-4hg-flex-tr,cisco/a9k-4t-b,cisco/a9k-4t-e,cisco/a9k-4t-l,cisco/a9k-8t-4-b,cisco/a9k-8t-4-e,cisco/a9k-8t-4-l,cisco/a9k-8t-b,cisco/a9k-8t-e,cisco/a9k-8t-l,cisco/a9k-mod160-se,cisco/a9k-mod160-tr,cisco/a9k-mod200-se,cisco/a9k-mod200-tr,cisco/a9k-mod400-se,cisco/a9k-mod400-tr,cisco/a9k-mod80-se,cisco/a9k-mod80-tr,cisco/a9k-rsp-8g,cisco/a9k-rsp,cisco/a9k-rsp440-se,cisco/a9k-rsp440-tr,cisco/a9k-rsp5-se,cisco/a9k-rsp5-tr,cisco/a9k-rsp880-lt-se,cisco/a9k-rsp880-lt-tr,cisco/a9k-rsp880-se,cisco/a9k-rsp880-tr,cisco/a9k-sip-700-8g,cisco/a9k-sip-700,cisco/asr-9922-rp-se,cisco/asr-9922-rp-tr, all @1 to @2. A ref naming an old major resolves to nothing; the distcontractnumber is unchanged. Their art keeps every port, lamp and legend at its drawn size and moves it in proportion. Bays on the ASR 9006, 9010, 9904, 9906, 9910, 9912 and 9922 keep their centres; the ASR 9010 slots are evenly spaced again. Cards that had been left out ofacceptsonly for size now seat:a9k-2x100ge-seanda9k-400g-dwdm-tron the 9006 and 9922,a9k-400g-dwdm-tron the 9912, anda99-10x400ge-x-se/-tranda9k-400g-dwdm-tron the 9904 (#16). -
The ASR 9001 MPA bays reserve the MPA envelope, 34.54 x 161.8, with the measured hole as their
opening, matching the A9K-MOD carriers; both SIP-700 cards reserve 167.87 for all four SPA subslots. -
Pluggable cage accept lists (
cages[].accepts) now apply the rate ceiling to the vendor cable ends: a part is offered only in a cage at or above its rung. The seven cable-end wrappers (1.1.0) state that rung asattrs.rate; they saidmedia, which the ceiling does not read, so every one was offered in every cage of its family - the 10G SFP+ DAC in 1G SFP cages, the 200G QSFP56 cable in 100G QSFP28 cages. Their exports listrate:where they listedmedia:. -
Ten SFP-class ports stated
media: sfp(the 1G rung) for 10G SFP+ or 25G SFP28 ports their own descriptions name: the SFP groups ofedgecore/agr560,eps112,eps121,eps122(nowsfp-plus) andeps201,eps202,eps203(nowsfp28), theedgecore/dcs520management SFP+ ports and thejuniper/mx304PTP port (sfp-plus). Theiroptics-sfpprose follows the media tooptics-sfp-plus/optics-sfp28. Exported interface types do not change. -
Lint L102 refuses a part that mates a pluggable family and names one of that family's rungs as
mediainstead ofrate. Lint L12 refuses a configuration that seats a part whoserateis above its cage's media on the part's own family ladder. -
Lint L12 now lets a configuration seat what a cage's accept list offers through its family's
also-accepts(a QSFP part in a QSFP-DD cage), which it refused; a QSFP cage still refuses a QSFP-DD part. The rate check also covers a cage on a seated card, reading the card's own part and group media (#630). -
generic/qsfp-lc@1andgeneric/qsfp-dd-lc@1are superseded by@2(above);@1is kept for fixtures pinned to it. -
common/qsfp-pull-tab@1is superseded by@2(above);@1is kept, with itswhiteandblueskins, forcommon/qsfp-transceiver@1, which still composes it. -
Lint L121 no longer holds a feature that starts at or behind the back of a part's
head:(a cable end's strap and ring) to the head envelope. -
Lint L99 refuses
cable-kindon a generic, as it refuses rate and reach. -
A component preview now also takes in the part's own relief features and the preview of each part it composes, so a wrapper's preview shows its generic's head, strap and ring.
-
common/qsfp-pull-tab@2(2.0.3) labels its photograph readingsphoto-measured, notmeasured: the arm features,size-confidence.hand theshapeprovenance. -
The three component previews whose part declares an overhanging
head:(generic/sfp-rj45,generic/qsfp-lc,generic/qsfp-dd-lc) are framed to include it, instead of clipping to the part's size box. -
The S8901-54XC management jack now renders its declared black finish (
#2b2f33) on the composedstd/rj45@2housing it seats, instead of the housing's own default; this is what the kit already painted at runtime. -
ufispace/psu-132-acandpsu-132-dc(1.1.0) describe and default to the EXHAUST units, PSU-132-AESR and PSU-132-DESR, which are front-to-back for a rear-mounted supply. They claimed the intake AISB1/DISB1 were front-to-back. The S9300-32D and S9301-32DB front-to-back builds named the intake parts and now name the exhaust ones, and their back-to-front builds name the intake ones. The reasoning is on the part'sairflowprovenance, and apsu-airflow-sku-mappinggap records that no document for these chassis states the pairing (#513). -
The Edgecore CSR440's airflow is
front-to-back, notside: every row of its datasheet ordering table says so, where the side-breathing CSR310 and CSR200 say "Side-to-Side". -
The COR580 AC build and the DCS510 state
power: [ac, hvdc]: their 1300 W AC supply is also rated 190-310 VDC. The DCS510'sinput-dcattr, which held that figure and read as a -48 V build it does not sell, isinput-hvdc. -
The Edgecore, UfiSpace and Celestica devices spell their input ratings one way,
input-acandinput-dcunderattrs.power, so the SVG root'sdata-power-input-ac,data-psu-ac-input,data-psu-input-ac,data-ac-inputanddata-system-input-rating-per-psu(and their DC twins) are nowdata-input-ac/data-input-dc. A bareinputthat held both ("AC 100 to 240V...; DC -36 to -72V...") is split into the two keys, and the DCS510'spower-input-ac-currentisinput-ac-current. Values are unchanged; each device took a patch bump (#513). -
Every fibre a connector declares is now a node you can address: a bore or a
class: fibreelement numbered1throughoptical.positions,X/non a port that carries more than one. Lint L112 holds it - a connector composes a bore for each position or draws its own fibre element, and a cassette's rear face reuses none of the front's ids. The three duplex adapters (common/lc-duplex-adapter,common/lc-duplex-v-adapter,common/sc-duplex-adapter) move to v5 for it: their two bores are1and2, nottxandrx, so a consumer addressing.../txor.../rxon one of these adapters finds nothing where it used to find a bore (a transceiver's own tx/rx faces are unchanged). 29 parts that compose one of these adapters took a major bump, and the five devices that seat them followed:fs/fhd-1ufce4.0.0,smartoptics/dcp-22.0.0,smartoptics/dcp-m32-cso-zr3.0.0,smartoptics/dcp-r-34d-cs4.0.0 andsmartoptics/dcp-r-9d-cs4.0.0. The MPO/MTP flange adapters (common/mpo-flange-adapter,common/mpo24-flange-adapter) carry a newopeningelement for the keyed bulkhead itself,class: portand markeddata-inner="1"so[data-class=port]:not([data-inner])still counts one connector per adapter, and fibre elements1..12(the 24-fibre part1..24), numbered as the plug numbers them rather than as a viewer sees them. Both adapters took a minor bump, 1.1.1 to 1.2.0 (#533). -
A SPANNING SLOT'S
cages[].rotateIS THE SUMMED TURN, not the placement's own. A duplex connector is one moulding and cannot turn itself, and the two LC duplex adapters run their pairs on different axes, so a slot that spans two bores publishes its placement'srotateplus the turn carrying the canonical across-axis onto its own bores: an unturned FS stacked adapter's slot publishes270. That is the turn the build seats its occupant at. Every other entry'srotateis its placement's as before,nullincluded.mateis still taken through the placement's ownrotatealone. -
Majors, each a new directory with the old one removed:
common/lc-duplex-adapterandcommon/lc-duplex-v-adapter@5 to @6 (they composestd/lc-bulkhead-bore@1, and the Smartoptics adapter's ferrule axis moved 0.32 within its body, with its placements moved to keep every fibre where it was);std/mpo@1 to @2 (its opening corrected to what an MPO plug can enter), withcommon/mpo-adapter, which composes it, andcommon/mpo-flange-adapterandcommon/mpo24-flange-adapter, which take its opening and are nowmposlots, @1 to @2;common/lc-duplex-shuttered-adapter@1 to @2 (now a slot, with two bores);generic/lc-plug@1 to @2 (drawn latch down, in its bore's convention). A ref naming an old major resolves to nothing. The distcontractnumber is unchanged, as it was for #533. -
ufispace/n3100-4cIS NO LONGER A DEVICE. The UfiSpace N3100-4C timing card leftdevices.json, and itsdevice-types/UfiSpace/N3100-4C.yamlexports with it. It is nowufispace/n3100-4c@1, a full-height PCIe card module, exported asmodule-types/UfiSpace/N3100-4C.yamlwith four 25G SFP28 interfaces and its SMB/SMA timing jacks, and accepted by every full-height slot of the Dell R740xd's risers (#625). -
Majors, each a new directory with the old one removed, because the full-height PCIe bracket was drawn mirrored (its keyed flange steps up, seen from outside with the tip at the left):
std/pcie-bracket-fh@1 to @2 (its body moved 3.17 down inside an unchanged box, so itsopeningelement is at y 6.35),dell/pcie-filler-fh-14g@1 to @2 andcommon/pcie-card-fh@1 to @2 (drawn in the bracket's frame, so they moved with it; the generic card also gained a body built from PCIe CEM 5.0), and the ten Dell risers whose bays seat it -dell/riser-1-none-14g,riser-1a-14g,riser-1b-14g,riser-1d-14g,riser-2a-14g,riser-2d-14g,riser-2e-14g,riser-2f-14g,riser-3a-14gandriser-3b-14g@1 to @2, their full-height bays moved to keep every opening where it was. A ref naming an old major resolves to nothing. The distcontractnumber is unchanged (#625). -
Ten routing-engine, control-board and sled modules now group their ports:
juniper/jnp10k-re1@2,re-s-1300@1,re-s-1300-v@1,mx2000-cb-re-v@1,mx2008-rcb-v@1,jnp10003-rcb@1,jnp304-re@1,mx104-re@1,cisco/a99-rp-f@1andedgecore/amx-3200-sled400@1. Management and timing jacks are rolemanagement, and the sled's CFP2 and QSFP28 ports are roletrafficat 400g and 100g. Management Ethernet states 1g where a guide gives the rate; the RE-S-1300's sources disagree, so it has none. The port media are corrected: console and auxiliary portsrj45-serial, ToDrj45-tod, BITSrj48(all wererj45). Each module took a minor bump, and the fifteen devices that seat them took a patch bump. Part ids are unchanged (#511). -
Timing and console jacks say what they carry in
data-mediainstead ofrj45: ToD and PPS/ToD jacks arerj45-tod, BITS and external-clock jacksrj48, stacking-sync jacksrj45-sync, the CSR440's alarm jackrj45-alarm, and consoles and AUX portsrj45-serial(rolesconsole/aux). A selector for[data-media='rj45']now finds Ethernet only. 33 more device-level ports gained adata-speedtheir sources state - the MX150's ten copper access ports, management jacks across Cisco, Juniper, Edgecore, UfiSpace, Celestica and MaiaEdge, the ASR 9001's cluster ports (10g, media nowsfp-plus), its and the ASR 9901's IEEE 1588 service LAN ports (100m), and three Smartoptics OSC cages (1g). Device types follow: those OSC cages and the ES1010 management SFP export as1000base-x-sfp(were25gbase-x-sfp28, a default), the ASR 9001 cluster ports as10gbase-x-sfpp(were25gbase-x-sfp28), the service LAN ports as100base-tx(were1000base-t), and 24 device types gain theConsoleconsole port they had been missing. Lint L113 holds it; 58 devices took a patch bump (#511). -
data-speedis spelled from one closed set -10m 100m 1g 2.5g 5g 10g 20g 25g 40g 50g 100g 200g 400g 800g 1.6t, inspec/schemas/speeds.yaml- and means the highest native rate the port runs at. Values a consumer may filter on changed:100m-1g,1000base-t,100/1000base-tand10/100/1000are all1g;400g-capableis400g; the MX304's GM/PTP port is10g, with its reserved-for-future-use caveat moved to the placement's description. USB generation leftspeedfor its owndata-usb(2.0,3.0; wasusb2,usb-2.0,usb3,usb-3.0), and the HLX-TGV's PON port isspeed: 10gwithdata-pon="xgs-pon"(was10g-pon). The MX304 LMIC16's twelve 100G-only ports now state100g(its module type still exports all sixteen by the cage, as400gbase-x-qsfpdd, as before). Lint L110 holds the set. 63 devices took a patch bump, andjuniper/mx304-lmic16,juniper/jnp304-reandsmartoptics/dcp-f-a22a patch each (#512). -
Device types export the CSR180's and CSR200's four RJ45 traffic ports each as
1000base-t; their100/1000base-tspelling had no interface-type row, so all eight exported nothing. For the same reason the management SFP on the DCP-2, DCP-R-34D-CS and DCP-R-9D-CS (100m-1g) now exports as a management-only1000base-x-sfp, and the MX304's GM/PTP SFP as a management-only10gbase-x-sfpp(#512). -
attrs.features.vendor-alias,attrs.features.marketing-nameandattrs.platform.oem-aliasare gone fromconfigs.jsonattrs, and from the facts list in the DCIM exports' comments. Their values moved to the top-levelaliasesabove, with any caveat kept as the alias's note in the manifest; the exports' comments name the aliases on an "Also sold or listed as" line instead (#514). -
group-roletakes a sixth value,fabric: the cell or chassis interconnect ports of a distributed chassis. The 241 fabric ports on nine DDC boxes carrydata-group-role="fabric"where they carriedtraffic(the S9700-53DX, S9701-82DC, S9705-48D, S9710-76D, S9720-56ED, S9725-64E, COR550 and COR580) orservice(the S9700-23D), so a filter ontrafficnow sees fewer ports and[data-class="port"][data-group-role="fabric"]selects exactly the fabric. Group names and port ids are unchanged, and the NetBox and Nautobot exports list these ports as interfaces exactly as before. Fabric CARD slots stayservice(#510). -
A pluggable cage's
rotate, and socages[].rotate, has one meaning: 0 is a module seated upright, bail at the top and belly at the bottom. Every belly-to-belly SFP/QSFP/QSFP-DD stack is drawn upper 0 over lower 180, or left 270 beside right 90 on a card drawn on its side, so an optic seated by its cage's turn has its bail outward; the std cage skins draw their lip at the bottom of the opening,common/qsfp-cage@3its flange, and lint L108 holds the rule. 62 devices took a major bump for turned or re-anchored placements and 85 cards a minor; OSFP stacks are left as drawn (docs/pluggables-3d-design.md, S1-S8). -
Exported
descriptionfields are cut at a word boundary with a trailing..., and bayAccepts:lists at a whole entry with(+N more). 266 descriptions used to end mid-word, and 62 were cut at a decimal point — the MX104's readJuniper MX104 - a 3(#187). -
Module-type port lists are ordered by name rather than by where the jack is drawn, so a card and its rotated twin produce one document (#267).
-
The Edgecore 2RU fan tray is
edgecore/fan-2u-1x1sn@1incomponents.jsonand in every bay that seats it; it wasedgecore/ais800-64-fan@1, which named one of the three chassis that share the part.AIS800-64D,AIS800-64OandAGR560took a major bump for the changed bay addressing (#420). -
Five Edgecore module types export under the ordering code Edgecore prints instead of a description of the part:
FAN-1U-1x1E(wasAS5835-54X Fan Tray),FAN-1U-1x1N(AS9726-32DB Fan Tray),FAN-1U-1x1J-S(AS7315-27X Fan Tray),SPAACTN-03BG(AS7315-27X AC PSU) andCRXT-T0T12BS(AS7315-27X DC PSU). Both the document name and themodelfield move, incomponents.jsonand in the NetBox and Nautobot module-type exports, so a consumer matching on an old name finds nothing where it used to find a module type (#426). -
dell/riser-lower-trim-14g@1is retired and leavescomponents.json, and the R740xd's rear placementriser-1-trim(rear/placements/riser-1-trim) is gone from every configuration; the R740xd takes a major, 24.0.0. The strip hid the bottom riser-1 card's keyed flange, whichstd/pcie-bracket-fh@1drew stepping down past the plate;@2steps it up, and Dell's service model has no metal there in front of the rear sheet (#623). -
A forwarding wrapper's presented depth now includes its composed core's own seat out, not only the wrapper's placement
lift:common/sma-jack@1,common/smb-jack@1,common/bnc-jack@1andcommon/din-1-0-2-3-jack@1(and the library's other bezels) present as deep as their core stands bare.std/mcx@1's mate moveson: barrel(2.0), so a seated MCX plug now stands proud of the panel by the barrel's height rather than at the panel plane; the MCX cages oncasa/c100gandcasa/c40g(104 placements) published lift 0 before this and 2.0 after, and both took a patch bump.std/bnc@1,std/din-1-0-2-3@1andstd/f-type@1each carry aseat-out(3.7, 3.85 and 7.8 respectively), so a seated plug on those jacks now presents at the mated plane instead of the panel face. -
The Cisco T3/E3 SPAs
spa-2xt3e3,spa-4xt3e3,spa-2cht3-ce-atmandspa-4xct3-ds0(1.1.0) draw their 1.0/2.3 jacks as realcommon/din-1-0-2-3-jack@1placements instead of skin art, so they now publishkind: connectorslots;cisco/asr-9010, the only device that seats one of them, took the patch bump devicelock asked for. -
juniper/mic-3d-8ds3-e3andmic-3d-8ds3-e3-v(1.1.1) correct their description: the SMB-opening jacks are drawn because the hardware is 75-ohm mini-SMB, not because "no BNC standard exists in the registry yet". The jacks and their placements are unchanged. -
Devices bumped for the coax jack and seat-out changes above:
casa/c100g,casa/c40g,cisco/asr-9010,commscope/ch3000,juniper/mx2008,mx2010,mx2020,mx240,mx480,mx80andmx960(#650).
The dist contract: number does not move for the pluggable-heads entries in
this section (the superseded QSFP generics and pull tab, the wider head
previews and the S8901-54XC finish correction): each is additive (a new key,
a new part, a superseded-not-removed part, a wider preview frame, a colour
correction), per this file's own rule. Nor does it move for the coax entries
above: the six interfaces, the new jacks, plugs and seat-out key are all
additions, and the moved SPA jacks and the corrected MIC description change
no field a reader already depends on.
- A seated part turns with the aperture it is in when its host FORWARDS that
aperture from a composed part (#548). The composed part's
own
rotatewas left out, so a plug seated in generic/sfp-lc-simplex@2 or generic/sfp-rj45@1 (each composes its one aperture at 180) was drawn 180 degrees out, and an opticmate-toa card whose cage is a part at 90 was drawn crosswise. The drawnrotate()of such a seat changes, and so do those two parts'presents.rotateincomponents.json(now 180). No device in the library seats either case today, so no compiled face changes. devices_indexfails when two devices share a name. Dist filenames carry no vendor, so they would otherwise render over each other in silence (#185).
The build had no version, no tag and no changelog: a consumer could not tell a
breaking change from a Tuesday. Everything before contract: 1 is unversioned
and should be re-fetched rather than diffed.