The program uses flags to handle data sources in the same output table being acquired on two different time bases (i.e. the slowsequence_disable_flg). This is a necessary approach related to correctly triggering data tables with simultaneous scans happening.
A new slow sequence was added in 7c72723 for acquiring data from soil probes, which includes new flag slowsequence_5_disable_flg. This flag is
- correctly flipped at the end of the new slow sequence
- correctly reset at the end of the primary scan,
- correctly updated for TDR-related columns in final data tables
- not correctly updated for 5TM-related columns in final data tables
No impact on historical data since it only affects Decagon (METER) 5TM probes. Need to update 5TM processing to use correct flag.