31 changes: 22 additions & 9 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -171,25 +171,34 @@ Program the following tags in section **[851]** for your chosen integration slot

### Programming Steps

1. **Enter Installer Mode:** `*8` → Installer Code → `[851]`
1. **Enable the TL-280**
- Enter [*][8][installer code][382] and set option 5 to ON. Press # to move back up to the configuration menu.
- Enter [300]. For subsections [001] to [004], program the subsection 02 to 06. If you also have a phone connection (some alarm installers use a phone connection to interface with their own communications boxes), keep option 1 enabled.
- Press # to move back to the configuration menu

2. **Read Integration ID (`[422]`):**
2. **Configure the TL-280:** Enter `[851]`
- Ensure that [021] is not set to 000000 or FFFFFF
- Ensure that [101] is not set to 000000 or FFFFFF
- Set [103] to the IP address of the system that the alarm will communicating with


3. **Read Integration ID (`[422]`):**
- Navigate to tag `[422]`
- **Note:** This field is read-only and displays your panel's unique 12-digit Integration ID
- Write down this value - you'll need to enter it in NeoHub's settings
- Example: `123456789012`

3. **Select Your Integration Slot:**
4. **Select Your Integration Slot:**
- Choose an available integration slot (1-4) that isn't already in use
- Use `[423]` for Integration 1, `[450]` for Integration 2, `[477]` for Integration 3, or `[504]` for Integration 4

4. **Program Type 1 Access Code:**
5. **Program Type 1 Access Code:**
- Navigate to your chosen integration tag (e.g., `[423]` for Integration 1)
- Enter your 8-digit Type 1 code (e.g., `12345678`)
- Press `#` to save
- **Important:** Remember which slot you used and the code you entered

5. **Program Type 2 Access Code (`[700]`-`[703]`):**
6. **Program Type 2 Access Code (`[700]`-`[703]`):**
- **Note:** Type 2 Access Code tags are specific to each integration slot
- For your chosen integration slot, navigate to the appropriate starting tag
- The 32-character hex key is split into 4 segments of 8 characters each
Expand All @@ -203,14 +212,18 @@ Program the following tags in section **[851]** for your chosen integration slot
- Enter characters 25-32
- Press `#` to save

6. **Configure Network Settings:**
- Set the panel's IP address for the NeoHub server (section `[801]`)
- Set the port to `3072` (or your configured `ListenPort`)
7. **Configure Network Settings.** For integration 1:
- Set [425] to 3, 4, and 5; this enables the system to operate over TCP with push notifications
- Set [426] to 3; this enables push notifications
- Set [428] to the IP address of the system that the alarm will communicating with
- Set [429] to 0C00 (port 3072)

7. **Exit Installer Mode:** Press `*99`
8. **Exit Installer Mode:** Press # several times

> ⚠️ **Critical:** The values programmed in the panel **must exactly match** the values in your `userSettings.json` file.

> ⚠️ **Critical:** If you need to reset your TL-280, enter *8, then your installation code, then 851 to configure the communicator, then 999 followed by 00. This only wipes settings under the [851] area and will not impact your partitions, zones, codes, etc.

---

## 🏗️ Architecture
Expand Down