You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
When zones and enclosures are not 1:1, the zone component loads report values for "Sensible-Delayed" internal gains (People, Lights, etc.) are incorrect. They are calculated using the zone's internal gain radiant intensities instead of the enclosure intensities. These values also affect the delayed envelope components as well. This may impact results in models with air boundary surfaces and/or zones with multiple spaces in them.
Details
Some additional details for this issue (if relevant):
Version of EnergyPlus 24.2.0
Checklist
Add to this list or remove from it as applicable. This is a simple templated set of guidelines.
Defect files are example files 5ZoneAirCooled_AirBoundaries, 5ZoneAirCooled_AirBoundaries_Daylighting, 5ZoneAirCooledWithSpaces, 5ZoneAirCooledWithSpacesDaylightingIntMass, and 5ZoneAirCooledWithSpacesHVAC.
Ticket added to EnergyPlus Defect Complexity (Github Project)
Pull request created (the pull request will have additional tasks related to reviewing changes that fix this defect)
The text was updated successfully, but these errors were encountered:
mjwitte
changed the title
Zone Component Loads Report Incorrect when Zones and Enclosures are not the same
Zone Component Loads Report may be incorrect when Zones and Enclosures are not the same
Oct 4, 2024
Issue overview
When zones and enclosures are not 1:1, the zone component loads report values for "Sensible-Delayed" internal gains (People, Lights, etc.) are incorrect. They are calculated using the zone's internal gain radiant intensities instead of the enclosure intensities. These values also affect the delayed envelope components as well. This may impact results in models with air boundary surfaces and/or zones with multiple spaces in them.
Details
Some additional details for this issue (if relevant):
Checklist
Add to this list or remove from it as applicable. This is a simple templated set of guidelines.
Defect files are example files 5ZoneAirCooled_AirBoundaries, 5ZoneAirCooled_AirBoundaries_Daylighting, 5ZoneAirCooledWithSpaces, 5ZoneAirCooledWithSpacesDaylightingIntMass, and 5ZoneAirCooledWithSpacesHVAC.
Ticket added to EnergyPlus Defect Complexity (Github Project)
Pull request created (the pull request will have additional tasks related to reviewing changes that fix this defect)
The text was updated successfully, but these errors were encountered: