Skip to content

NuDot/DAQ-30-channel

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

13 Commits
 
 
 
 
 
 
 
 

Repository files navigation

DAQ-30-channel-test

Collection of scripts to run and setup the HV crate

I believe the PMT target voltage is 1750v

crate_voltage.txt is where you write in the voltage/gain specifics for each pmt

set_crate_voltages.sh sets voltages based on values in crate_voltage.txt

turn_off_PMT_voltages.sh sets all PMT voltages to 0

Page 21 is where all of the net-snmp commands start being explained. http://file.wiener-d.com/documentation/MPOD/WIENER_MPOD_Manual_2.7.1.pdf

########################################################################################## brief notes on commands, options and arguements to follow... ##########################################################################################

this prints out the channel, voltages, currents, and wether its on or off. same as when you type http://198.125.161.201 into a webrowser url. it has 7 columns of data --------V snmpwalk -Cp -Oqv -v 2c -m +WIENER-CRATE-MIB -c public 198.125.161.201 crate

this command tells you how many channels you have avaialable----V snmpget -Oqv -v 2c -m +WIENER-CRATE-MIB -c guru 198.125.161.201 outputNumber.0

the borrowed module has 16 channels each of the other modules (4) has 48 each