iKettle 2.0 and Smarter Coffee Interface
iBrew is a (python) interface to iKettle 2.0 and Smarter Coffee devices. It includes a console, monitor, command line interface and bridge to Domoticz. You can also use it in your own code. iKettle 2.0 v19 tested only. Please share you Smarter Coffee codes or any other discoveries you made.
This means your machine is free! You can connect it yourself and do whatever you want with it. You are in full control! You can also interface it with your favorite smarthome controller. A working bridge to domoticz is already included (which you can bridge with homekit or other fun stuff)!
Signed TRiXWooD
- v0.0 Bean Grinder Pack
- v0.1 White Tealeaf Edition
- v0.2 Tea Noire Sweet
- Better error handling
- Final arguments
- Auto reconnect
v0.3 Kettle Rattle
Please donate raw codes or donate (for) a (working) Smarter Coffee (interface), can not test without one or without help! Someone please run iBrew sweep
on there coffee machines and post the results in the issues.
Bugs or issues. Donations & other questions [email protected]
- python 2.7
You can download and unpack the source or download it from github using
git clone https://github.com/Tristan79/iBrew.git
See the console section for the commands
Usage: iBrew (dump) [command] (host)
host host address (format: ip4, ip6, fqdn)
dump dump message enabled
command action to take!
Start the console with the command iBrew console
. The following commands are available within the console,
you can also use them on the command line as arguments:
iKettle 2.0 & Smarter Coffee Commands
default set default settings
info device info
history action history
list list detected devices
reset reset device to default
start start the device
status show status
stop stop the appliance if its brewing or boiling
time [time] set the device time
[hexdata] send raw data to device (e.g. '64 7e')
iKettle 2.0 Commands
base show watersensor base value
base [base] store watersensor base value
calibrate calibrates watersensor
formula ()() heat kettle in formula mode
heat ()() heat kettle
settings show user settings
settings [] [] [] [] store user settings
stop kettle stops boiling
Smarter Coffee Commands
brew brew coffee
carafe returns if carafe is required
cups [number] set number of cups [1..12]
grinder toggle grinder
hotplate off turn hotplate off
hotplate on (minutes) turn hotplate on (time in minutes)
singlecup return if singlecup mode is on
strength [strength] set strength coffee [weak, medium or strong]
stop coffee stops brewing
Wireless Network Commands
join [net] [pass] connect to wireless network
leave disconnect (and open direct mode)
scan scan wireless networks
Protocol Help Commands
examples show examples of commands
messages show all known protocol messages
message [id] show protocol message detail of message [id]
notes show developer notes on the devices
structure show protocol structure information
Bridge Commands
domoticz show domoticz bridge help
Debug Commands
dump toggle 'dump raw messages'
console start console [Command line only]
firmware show firmware Wifi
monitor monitor incomming traffic
protocol show all protocol information available
sweep (id) try (all or start with id) unknown command codes
Console Commands
joke show joke
quit quit console [Console only]
Example:
off iKettle 2.0 Stop boiling
messages Show all protocol messages
message 3e Show protocol message 3a, turn hotplate on
167E Send iKettle 2.0 raw off
21 30 05 7e Send iKettle 2.0 raw on
strength weak Set SmarterCoffee coffee strength to weak
cups 3 Set SmarterCoffee number of cups to brew
Bridge to Domoticz. You are in full control!
Domoticz Bridge
_______________
Bridge between iKettle 2.0 and domoticz. Its auto-creates 4 devices in domoticz, if not yet created,
and monitors the kettle and update the domoticz devices accordingly.
Water Temperature in ΒΊC (temperature device)
Water Height (custom device)
Kettle on base (motion device)
Kettle status (text device)
Currently you have to create your boil, brew switches yourself (working on it), so:
Place or link iBrew in your domoticz script folder or somewhere readable and reachable.
Run iBrew in domoticz bridge mode to auto create the 'smarter' dummy hardware.
Go to [SETUP] [HARDWARE] press 'create virtual sensors' on the dummy hardware called 'smarter'
Give it a name (e.g. Kettle Boil) and select sensor type is switch.
Go to [SWITCHES], scroll all the way down.
Select 'edit' on your newly created device.
Switch Icon, well heating is nice!
On Action: script://locationibrew/iBrew on kettleip
Off Action: script://locationibrew/iBrew off kettleip
You now have a functional boil/stop switch...
If you do not want a switch you can also create two push (on/off) buttons
and fill in the action.
If you use homebridge for domoticz (https://www.domoticz.com/forum/viewtopic.php?t=10272) you can use
apple homekit with the kettle. You have to create extra virtual sensor (motion boil???) because the text sensor is not supported
by homekit, all the other are.
Usage:
domoticz [domoticz] [basename] [kettle]
Where:
domoticz Connection string to domoticz, [host:port] or [username:password@host:port]
basename Base name of your kettle devices in domoticz. The name may contain spaces.
kettle Connection string to iKettle 2.0, [host]
host Format: ip4, ip6, fqdn
Notes:
It will auto-create the devices in Domoticz
Tested on Domoticz v3.52
*** Currently iKettle 2.0 Only ***
Examples:
iBrew domoticz sofia:$ecrit@localhost:8080 Kettle Kitchen 192.168.4.1
iBrew domoticz 10.0.0.1:9001 Kettle Office 192.168.10.13
iBrew dump domoticz 10.0.0.1:9001 Kettle Office 192.168.10.13
iBrew domoticz localhost:8080 Kettle
Example keepalive LaunchAgent for macOS/OSX, i soft linked /usr/local/bin/ibrew to iBrew. But you can change it to your normal copy, also change the working directory,domoticz ip and kettle ip.
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE plist PUBLIC "-//Apple//DTD PLIST 1.0//EN" "http://www.apple.com/DTDs/PropertyList-1.0.dtd">
<plist version="1.0">
<dict>
<key>Disabled</key>
<false/>
<key>KeepAlive</key>
<true/>
<key>Label</key>
<string>com.domoticz.ikettle</string>
<key>ProgramArguments</key>
<array>
<string>/usr/local/bin/ibrew</string>
<string>domoticz</string>
<string>10.0.0.1:8090</string>
<string>Kettle</string>
<string>10.0.0.99</string>
</array>
<key>RunAtLoad</key>
<true/>
<key>WorkingDirectory</key>
<string>/Users/Tristan/Smarthome/domoticz/scripts</string>
</dict>
</plist>
Smarter iKettle 2.0 & Smarter Coffee Protocol
_____________________________________________
Smarter uses a binary message protocol, either via UDP or TCP on port 2081
Messages (commands and responses) use the syntax:
<ID>[ARGUMENTS]<TAIL>
Arguments use this syntax:
<ARGUMENT> is a single mandatory byte
<[ARGUMENT]> is a single optional byte
<ARGUMENT>{x} is mandatory, between 1 and x bytes
The tail is always 7e or ~ in ASCII, everything else are ASCII literals
There are some value's like the watersensor that can contains the tail
so check the length of the response message!
Smarter iKettle 2.0 & Smarter Coffee Messages
_____________________________________________
k c ID Command Message
___________________________________________
β ? 02 Set device time
β ? 05 Set wireless network name
β ? 07 Set wireless network password
β ? 0c Join wireless network
β ? 0d Scan for wireless networks
β ? 0f Leave wireless network
β β 10 Reset default user settings
β ? 15 Heat kettle
β ? 16 Stop heating kettle
β ? 19 Heat kettle using formula mode
β ? 1f Set kettle default user settings
β ? 20 Working unknown command (turn on?)
β ? 21 Working unknown command (turn on?)
β ? 22 Working unknown command (turn on?)
β ? 23 Working unknown command (turn on?)
β ? 28 Get History Device
β ? 2a Set water sensor base value
β ? 2b Get water sensor base value
β ? 2c Calibrate water sensor
β ? 2e Get default user settings
β ? 30 Working unknown command
β β 33 Start coffee brewing
β β 34 Stop coffee brewing
β β 35 Set strength of the coffee to brew
β β 36 Set number of cups to brew
β β 37 Start coffee brewing using default
β β 38 Set coffee machine default user settings
β β 3c Toggle grinder
β β 3e Turn on hotplate
β β 40 Working unknown command (schedule?)
β β 41 Working unknown command (schedule?)
β β 43 Working unknown command (schedule?)
β β 4a Turn off hotplate
β β 4c Coffee Carafe Required Status
β β 4f Coffee Single Mode Status
β β 64 Get device info
β ? 69 Working unknown command
β ? 6a Get wifi firmware info
β ? 6d Device firmware update
k c ID Response Message
_______________________________
β ? 03 Command status
β ? 0e Wireless networks list
β β 14 Kettle status
β ? 29 Device history
β ? 2d Water sensor base value
β β 2f Default user settings
β β 32 Coffee machine status
β β 4d Carafe status
β β 50 Single cup mode status
β β 65 Device info
β ? 6b Wifi firmware info
Legend:
k iKettle 2
c Smarter Coffee
Command Message 02: Set device time
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 ? Smarter Coffee
Set the time on the device, is used in history reply messages.
Unknown is Day of week index?
Arguments: <SECONDS><MINUTES><HOURS><??><DAY><MONTH><CENTURY><YEAR>
SECONDS
00..3b
MINUTES
00..3b
HOURS
00..17
DAY
00..1e
MONTH
00..0b
CENTURY
13..15
YEAR
00..63
Example: 00 00 00 00 00 00 00 00 ???
Response Message 03: Command status
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
In response to command message: [02,Set device time] [05,Set wireless network name] [07,Set wireless network password] [10,Reset default user settings] [15,Heat kettle] [16,Stop heating kettle] [19,Heat kettle using formula mode] [1f,Set kettle default user settings] [20,Working unknown command (turn on?)] [21,Working unknown command (turn on?)] [22,Working unknown command (turn on?)] [23,Working unknown command (turn on?)] [2b,Get water sensor base value] [2c,Calibrate water sensor] [69,Working unknown command]
Message Size: 3 bytes
β iKettle 2.0 ? Smarter Coffee
Response: <STATUS>
STATUS
00 Success
01 Busy
02 No Carafe (Coffee unverified)
03 No Water (Coffee unverified)
04 Failed
05 No Carafe
06 No Water
69 Invalid Command
The response status of the coffee can be bit encoded (see response 14)
Command Message 05: Set wireless network name
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 ? Smarter Coffee
Argument: <SSID>{0,32}
Just normal ascii
Command Message 07: Set wireless network password
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 ? Smarter Coffee
Argument: <PASSWORD>{0,32}
Just normal ascii
Command Message 0c: Join wireless network
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 ? Smarter Coffee
Sending this command without previous SSID/password messages will reset the wifi
to factory settings.
Send:
Set wireless network name
Set wireless network password
Join wireless network
Read all the command status ssuccess
The apps actually sends: 0c 7e 00 00 00 00 00 00
Command Message 0d: Scan for wireless networks
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [0e,Wireless networks list]
β iKettle 2.0 ? Smarter Coffee
Example raw code: 0d 7e
Response Message 0e: Wireless networks list
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
In response to command message: [0d,Scan for wireless networks]
β iKettle 2.0 ? Smarter Coffee
DB is the signal strength in dBm format.
Response: <SSID>{0,32}<",-"><DB>{2}<"}">
Examples: MyWifi,-56}
MyWifi,-56}OtherWifi,-82}
Command Message 0f: Leave wireless network
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 ? Smarter Coffee
Leaves wireless network and reset wifi to default
Example raw code: 0f 7e
It actually sends: 0f 7e 6d 7e
Command Message 10: Reset default user settings
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 β Smarter Coffee
For the kettle these are the default user settings:
keepwarm 0 minutes (0x00), temperature 100ΒΊC (0x64)
formula mode off (0x00) and formula temperature 75ΒΊC (0x4b)
The Smarter Coffee it will probably reset the number of cups and strength
Example raw code: 10 7e
Response Message 14: Kettle status
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Message Size: 7 bytes
β iKettle 2.0 β Smarter Coffee
There is correlation between the temperature the watersensor and the base. How higher
the temperature how higher the watersensor with the same volume of water.
Response iKettle: <STATUSKETTLE><TEMPERATURE><WATERSENSORBITSHIGH><WATERSENSORBITSLOW><??>
Response Smarter Coffee: <STATUSCOFFEE><WATERLEVEL><WIFISTRENGTH???/WATERSENSORBITSLOW???>
<STRENGTH><CUPS>
STATUSKETTLE
00 Ready
01 Boiling
02 Keep Warm
03 Cycle Finished
04 Baby Cooling
TEMPERATURE
00..64 0..100ΒΊC
7f Kettle Off Base
WATERSENSOR = WATERSENSORHIGHBITS * 256 + WATERSENSORLOWBITS
Command Message 15: Heat kettle
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 ? Smarter Coffee
if it's warming you have to send an off command to boil again
if it's not on temp it boils first before warming...
Argument: <TEMPERATURE><KEEPWARMTIME>
TEMPERATURE
00..64 0..100ΒΊC
KEEPWARMTIME
00 Default off
05..1e Keep Warm in Minutes
Example: 15 32 00 7e
Command Message 16: Stop heating kettle
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 ? Smarter Coffee
Example: 16 7e
Command Message 19: Heat kettle using formula mode
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 ? Smarter Coffee
Boil water to (default user temperature)
and cool until the formula temperature and then keep it warm.
Arguments: <FORMULATEMPERATURE><KEEPWARMTIME>
KEEPWARMTIME
00 Default off
05..1e Keep Warm in Minutes
TEMPERATURE
00..64 0..100ΒΊC
FORMULATEMPERATURE
00..64 0..100ΒΊC
Example: 19 32 19 7e
Command Message 1f: Set kettle default user settings
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 ? Smarter Coffee
Default user defaults message is 1f 00 64 00 4b 7e
Arguments: <KEEPWARMTIME><TEMPERATURE><FORMULA><FORMULATEMPERATURE>
KEEPWARMTIME
00 Default off
05..1e Keep Warm in Minutes
TEMPERATURE
00..64 0..100ΒΊC
FORMULA
00 Do not use as default
01 Use as default
FORMULATEMPERATURE
00..64 0..100ΒΊC
Example: 1f 19 64 01 22 7e
Command Message 20: Working unknown command (turn on?)
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 ? Smarter Coffee
This setting ignores the user setting and boils till 100C
Example raw code: 20 7e
Command Message 21: Working unknown command (turn on?)
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 ? Smarter Coffee
No information available on message: 21
Command Message 22: Working unknown command (turn on?)
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 ? Smarter Coffee
Example: 22 7e
Command Message 23: Working unknown command (turn on?)
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 ? Smarter Coffee
Example: 23 7e
Command Message 28: Get History Device
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [29,Device history]
β iKettle 2.0 ? Smarter Coffee
When called will erase this history.
Example: 28 7e
Response Message 29: Device history
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
In response to command message: [28,Get History Device]
β iKettle 2.0 ? Smarter Coffee
The payload is generated everytime the kettle stops boiling. The actioncounter increases with every boil
Formula temperature is above 0 then it was boilded with formula temperature enabled. There seems to be some
packed time available.
Response: <COUNTER> [<PAYLOAD>{COUNTER}]
PAYLOAD
<??><TEMPERATURE><KEEPWARMTIME><FORMULATEMPERATURE><ACTIONCOUNTER>
<ACTIONCOUNTER???/TIME???><TIME?><TIME?><DATE?><DATE?><???/DATE???><STATE><??>{19}
TEMPERATURE
00..64 0..100ΒΊC
KEEPWARMTIME
00 Default off
05..1e Keep Warm in Minutes
FORMULATEMPERATURE
00..64 0..100ΒΊC
ACTIONCOUNTER
00..ff
TIME/DATE?
STATE
00 Stopped
01 Boiled
Example: 29 02 01 5f 00 00 0f 00 09 03 15 0a 19 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 7d
01 64 19 32 10 00 09 0e 15 0a 19 01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 7d 7e
Command Message 2a: Set water sensor base value
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 ? Smarter Coffee
Arguments: <BASELHIGHBITS><BASELOWBITS>
BASE = BASELHIGHBITS * 256 + BASELOWBITS
Example: 2a 04 03
This can contain the tail 7e, so check for length here!
Command Message 2b: Get water sensor base value
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [2d,Water sensor base value] [03,Command status]
β iKettle 2.0 ? Smarter Coffee
Example: 2b 7e
Command Message 2c: Calibrate water sensor
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [2d,Water sensor base value] [03,Command status]
β iKettle 2.0 ? Smarter Coffee
Example: 2c 7e
Returns also a command success response message after the base repsonse message
Response Message 2d: Water sensor base value
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
In response to command message: [2b,Get water sensor base value] [2c,Calibrate water sensor]
Message Size: 4 bytes
β iKettle 2.0 ? Smarter Coffee
Response: <BASELHIGHBITS><BASELOWBITS>
BASE = BASELHIGHBITS * 256 + BASELOWBITS
This can contain the tail 7e, so check for length here!
Command Message 2e: Get default user settings
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [2f,Default user settings]
β iKettle 2.0 ? Smarter Coffee
Also return 00 message in an unconfigured state.
Example: 2e 7e
Response Message 2f: Default user settings
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
In response to command message: [2e,Get default user settings]
Message Size: 9 bytes
β iKettle 2.0 β Smarter Coffee
Response: <KEEPWARMTIME><TEMPERATURE><FORMULATEMPERATURE>
KEEPWARMTIME
00 Default off
05..1e Keep Warm in Minutes
TEMPERATURE
00..64 0..100ΒΊC
FORMULATEMPERATURE
00..64 0..100ΒΊC
Command Message 30: Working unknown command
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 ? Smarter Coffee
Arguments: <[UNKNOWN]>{?}
Example: 30 7e
Response Message 32: Coffee machine status
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
I do not have a smarter coffee, but I suspect that the WIFISTRENGTH is just
the WATERSENSORBITSLOW part of the waterlevel sensor.
Response: <STATUSCOFFEE><WATERLEVEL><WIFISTRENGTH???/WATERSENSORBITSLOW???><STRENGTH><CUPS>
STATUSKETTLE
00 Ready
01 Boiling
02 Keep Warm
03 Cycle Finished
04 Baby Cooling
WATERSENSOR = WATERSENSORHIGHBITS * 256 + WATERSENSORLOWBITS
STATUSCOFFEE (unverified)
04 Filter, ? # 00000100
05 Filter, OK to start # 00000101
06 Filter, OK to start # 00000110
07 Beans, OK to start # 00000111
20 Filter, No carafe # 00100000
22 Beans, No carafe # 00100010
45 Filter, Done # 01000101 <-- from here actions
47 Beans, Done # 01000111
53 Boiling # 01010011
60 Filter, No carafe, Hotplate On # 01100000
61 Filter, Hotplate On # 01100001
62 Beans, No carafe, Hotplate On # 01100010
63 Beans, Hotplate On # 01100011
51 Descaling in progress # 01010001
HB RBC
OO EEA
TI AAR
PL DNA
LI YSF
AN E
TG
E
These are guesses I do not own a smarter coffee...
BIT 0 = UNKNOWN/UNUSED?
BIT 1 = ACTION???
BIT 2 = HOTPLATE
BIT 3 = Boiling & Descaling (USES BIT 6)
BIT 4 = UNKNOWN/UNUSED?
BIT 5 = READY/BUSY (OK TO START, FINISHED = 1 else 0)
BIT 6 = FILTER/BEANS
BIT 7 = CARAFE OFFBASE/ONBASE
WATERLEVEL
00 Not enough water
01 Low
02 Half
12 Half
13 Full
STRENGTH
00 Weak
01 Medium
02 Strong
CUPS
00..0c
Command Message 33: Start coffee brewing
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
Example: 33 .. .. .. 7e
Command Message 34: Stop coffee brewing
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
NEW
Command Message 35: Set strength of the coffee to brew
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
Sets the strength of the coffee to be brewed. Use command 37 to brew
Argument: <STRENGTH>
STRENGTH
00 Weak
01 Medium
02 Strong
Example: 35 01 7e
Command Message 36: Set number of cups to brew
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
Sets the number of cups to be brewed, range between 1 and 12.
Use command 37 to brew
Argument: <CUPS>
CUPS
00..0c
Example: 36 03 7e
Command Message 37: Start coffee brewing using default
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
Example: 37 7e
Command Message 38: Set coffee machine default user settings
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
NEW
Command Message 3c: Toggle grinder
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
Example: 3c 7e
Command Message 3e: Turn on hotplate
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
Sets on the hotplate, you can specify how many minutes before it switch off.
Range between 5 and 30, the app sends 5 on default
Argument: <[KEEPWARMTIME]>
KEEPWARMTIME
05..1e 5 .. 20 minutes
05 5 Minutes (Default)
Example: 3e 05 7e
Command Message 40: Working unknown command (schedule?)
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
Updating schedules
No information available on message
Command Message 41: Working unknown command (schedule?)
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
Requesting schedules
No information available on message
Command Message 43: Working unknown command (schedule?)
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
Schedules
No information available on message
Command Message 4a: Turn off hotplate
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
Example: 4a 7e
Command Message 4c: Coffee Carafe Required Status
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
NEW
Response Message 4d: Carafe status
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
In response to command message: [4c,Coffee Carafe Required Status]
Message Size: 3 bytes
β iKettle 2.0 β Smarter Coffee
Response: <BOOLEAN>
Command Message 4f: Coffee Single Mode Status
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 β Smarter Coffee
NEW
Response Message 50: Single cup mode status
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
In response to command message: [4f,Coffee Single Mode Status]
Message Size: 3 bytes
β iKettle 2.0 β Smarter Coffee
Response: <BOOLEAN>
Command Message 64: Get device info
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [65,Device info]
β iKettle 2.0 β Smarter Coffee
Get the type of the device connected to and it's firmware. It is used for
auto discovery over UDP broadcast (after device setup is complete?)
This fails on some routers, which don't propagate UDP broadcasts
Example: 64 7e
Response Message 65: Device info
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
In response to command message: [64,Get device info]
Message Size: 4 bytes
β iKettle 2.0 β Smarter Coffee
Response: <TYPE><VERSION>
TYPE:
01 iKettle 2.0
02 Smarter Coffee
VERSION:
13 Firmware v19 of iKettle 2.0
Example: 65 01 13 7e
Command Message 69: Working unknown command
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [03,Command status]
β iKettle 2.0 ? Smarter Coffee
Without argumens it returns failed otherwise it returns success.
Arguments: <UNKNOWN>{?}
Example: 69 7e
Command Message 6a: Get wifi firmware info
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
Response message: [6b,Wifi firmware info]
β iKettle 2.0 ? Smarter Coffee
Example: 6a 7e
Response Message 6b: Wifi firmware info
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
In response to command message: [6a,Get wifi firmware info]
β iKettle 2.0 ? Smarter Coffee
The firmware of the wifi module in text with control chars as new line.
The iKettle 2.0 returns (without control chars):
Response: <FIRMWARE>{?}
AT+GMR
AT version:0.40.0.0(Aug 8 2015 14:45:58)
SDK version:1.3.0
compile time:Aug 8 2015 17:19:38
OK
Command Message 6d: Device firmware update
βββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββββ
β iKettle 2.0 ? Smarter Coffee
Disables wifi and creates a 'iKettle Update' wireless network and opens port 6000.
A hard device reset (hold power button for 10 seconds) is sometimes required to fix this state,
or just unplug the power for a moment.
Example: 6d 7e
Smarter iKettle 2.0 & Smarter Coffee Notes
__________________________________________
WaterSensor Calibration:
If the kettle is on the base during calibration, the numbers change to be higher,
but the differences between levels seem the same. This means that the water level
detection is probably weight based and that calibration is done at the base,
which then remembers the weight for 'off base'. To detect an empty kettle,
the connecting device must account for the weight of the kettle.
(yeah, not! the watersensor becomes higher if the temperature becomes higher...)
Wireless Network:
If the device (coffee?) is configured to access an wifi access point which is not available
It will try to connect to it every so minutes. If it tries to connect it beeps three
times the wifi access point of the device will remain active but unreachable,
if it fails to access the access point it beeps once, and it opens up its own default
open unencrypted wifi access point.access
If connected to the kettle tcp 192.168.4.1:2081 is the default connection.
The iKettle2.0 creates an access point with the name iKettle2.0:c0 where c0 is part
of the mac address of the kettle. When connected directly to the kettle its connection is very flacky.
Device Detection:
To detect a device broadcast a device info command (message 64) on UDP. It will reply
if the router permits it with a device info response (message 65) and being UDP
with its IP address!
Capturing the protocol using WireShark:
OSX: (Home Network Only)
Step 1: Download wireshark (https://www.wireshark.org/) for mac and install it.
Step 2: Setup your kettle or coffee machine to use your home network.
Step 3: Connect you mac to your network NOT using the build in wifi adapter.
Use either a cable (ethernet recommended) or a second wifi adapter.
Step 4: Enable and setup internet sharing in system preferences, sharing.
Step 5: Connect with your phone to the internet sharing wireless access point.
Step 6: Run wiresharp it and select your build in wifi adapter and start the capture.
Step 7: Look for connection with messages ending in 7e
iOS & OSX: (Home network & Direct mode)
Step 1: Connect your iOS device to your Mac via USB.
Step 2: Get the <udid> for the connected device from iTunes (click on the serial).
Step 3: Open terminal in your Mac and run the following commands, which creates a virtual network
adapter mirroring the iOS network, which we can dump and inspect:
Step 4: rvictl -s <udid>
Step 5: tcpdump -i rvi0 -w ~/Desktop/output.pcap
Step 6: Connect to kettle's wifi network (or your home network if already setup) on the iOS device.
Step 7: Run setup for smarter device setup, or any commands
Step 8: When done or the device setup disconnected to switch to your home network, disconnect with ctrl-c
Step 9: rvictl -x <udid>
Step A: Download wireshark (https://www.wireshark.org/) for mac and install it.
Stap B: Open ~/Desktop/output.pcap with Wireshark
Step C: Look for connection with messages ending in 7e
Security:
iKettle 2.0:
* It will boil empty, making the lights bulbs to flikker.
* You can easily knock out it's connection to the wireless network,
if it fails to connect it creates an default open unencrypted wifi access point
(check!, could be that wifi was not connecting, then this is rubbish ;-).
Attack Vectors
1. Repeat sending heat to 100ΒΊC temperature commands, if we're lucky
there is no water and it will boil empty, if not it will take a while.
plus the kettle will get warmer and warmer. If you do not expect that when touching.
2. Alternating heat and stop commands.
3. (Check) Wait until the owner of the kettle log in on the kettle, since its an
open access point and the password are send in the open you can read it.
Coffee Brewing:
Between setting the number of cups, the strength of the coffee and start of brewing
atleast 500ms is recommended.
Water Boiling:
From smarter website the temperature that can be set is between 20 and 100. We still need to read lower
values for cold water in the kettle
- Set Device Time is missing arguments in console
- Set default is missing arguments in console
- Boil has no arguments
- Brew has no arguments
- Auto-reconnect
- Missing Coffee Smarter codes
- History message is not finished
- [will not fix] Should read status message 14 all the time in console mode
- [will not implement] Default auto connect first coffee or kettle with no host
- https://github.com/Jamstah/libsmarteram2/
- https://github.com/ian-kent/ikettle2/
- https://github.com/athombv/am.smarter/
- https://github.com/nanab/smartercoffee/
- https://github.com/AdenForshaw/smarter-coffee-api
- https://github.com/Half-Shot/Smarter-Coffee-NET
- https://domoticz.com/forum/viewtopic.php?f=23&t=12837
- https://github.com/jkellerer/fhem-smarter-coffee/
- https://www.pentestpartners.com/blog/hacking-a-wi-fi-coffee-machine-part-1/