Repository navigation
Add the Server Technology PRO3X Smart 3C01, Switched 3F01 and Switched POPS 3G01 - #1914
Merged
Merged
Conversation
…d POPS 3G01 Each is the Basic 3A01 strip with a controller panel between the banks. The controller is one new module whose jacks reuse the library's parts and keys. The panel size and the outlet levers are estimated. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
The chassis note gave 81.2, the figure of the 3A06 drawing. The side view of the three data sheets prints 81.8. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…lugs, tabs and sides Each outlet gets the hole beside its numeral, and each bank its end lugs and edge tabs. The cover gets its two screw holes and the ground point a ring with a dot. A plain plate stands before the far breaker, and the controller plate gets two tabs for its notched outline. Each side gets two perforated zones, a seam, eleven screws and two nubs. Figures are read to about 1 mm from the sheets' 300 ppi rasters and written as estimates in the gaps. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…ts second stretch and the stepped housings The controller panel is 52.0 by 141.6, read from the sheet's front view, and its window, keys, holes and ring are placed from the same view. The plate gets its second wider stretch over the jack group and the notch at the measured depth. Each bank's housing steps in over its C13 outlets and sits where the sheet draws it. The two symbol labels move to the sheet's place. The 36 lever pegs, the nubs and the slope of the step are named in gaps, and every estimate states its tolerance. Three PROUD entries cover the levers' 18.3 reach. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…e sheet's raster and draw the tab holes, bottom-edge dots, plate tabs and controller notches The outlets, plates, housings and lugs stand where the sheet's front view puts them along the strip, to about 1 mm. Each top tab gets two holes and each C13 tab a notch. Each outlet gets a bottom-edge bump and dot, each Cx outlet a ring, and each blank plate a tab and two dots. The controller plate gets notches at the stretch ends and near the ring end, and a lip at the cord end. The outlet-size gap says why the shared Cx part is not changed here. The PROUD entries say the lever's place and across are photograph estimates. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…e breaker handle, add the rear seam and place each lever on its peg The sheet's breaker cell holds a framed square and a bar with two dots, so the shared breaker handle gets a second major and the first stays for the 3A01. Each lever stands on its peg's centre from the side view, to about 0.5 mm. The rear view draws its seam 119.8 mm from the cord end. The gaps state figure, method and tolerance. The table of majors kept on purpose lists the breaker handle. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…ver bar, and give every estimate its tolerance The side gap now gives the two boxes under the breakers and the flat bar under the cover, with figures and tolerance. The controller outline's tolerance is 1 mm, as the source raster resolves. The other-side and numbering gaps and the key size state theirs. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…name the small items under the body The side gap now gives the boxes at 175.9 to 237.6 and 1103.8 to 1165.8 from the cord end, to about 4 mm. That is the spread of three readings of the sheet's raster. It also gives the thin bar under each box and the cover bar. Five small items under the body from 887 to 1025 mm each get a figure and a tolerance. Depths are measured from the centre of the body's bottom line. The three devices carry the same text, and the tests read it. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…ar and split two long gap sentences The thin bar under each box is about 12 below the body, as two readings of the raster give 11.6 and 12.6. The flat bar under the cover now has its place, 2.9 to 55.2 from the cord end. The outlet-size and housing-step gaps each lose a sentence over 25 words, with the facts kept. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…nd uprights in the side gap The side view draws a ledge under each of the six banks, with a small square and a thin upright at each peg. The gap now gives each ledge's place, its depth, the method and a tolerance. The three devices carry the same note. A whole scan of the side view in bands of 100 mm found nothing else uncovered. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…ofile and state the rounds and end uprights Screws 5 to 11 were up to 2.4 mm off the sheet and now stand at its readings on both faces. The long dot band, the dot rows and the nub caps are re-placed to within 1 mm. The side gaps now give the screw centres, the scale and the method. The side-nubs gap adds 18 rounds under the first three pegs of each bank and 12 more uprights after each sixth peg. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…before each ledge and re-place small items The long dot band is 360 columns at 4.4964, as the sheet counts it, where it was 361 at 4.48. The cord-end block is 20 columns at 4.463. A thin upright stands before peg 1 of each ledge. The gap states them, 42 thin uprights in all. Screws 1 to 4, the seam and four levers move to their readings. Every lever stands within 0.3 mm of its reading at 1800 ppi. The tests check the tile counts, the middle dots, the seam and the six uprights. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com> Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
PREVIEW: needed (the three PRO3X fronts and sides, the controller panel, new devices)
Refs #1475
What this changes
Adds three 0U rack PDUs: the Server Technology PRO3X Smart 3C01, Switched 3F01 and Switched POPS 3G01.
Each is the Basic 3A01 strip with a controller panel between the two banks of outlets.
It adds one new module,
servertech/pro3x-controller, seated in a bay on each device.It also adds a second major of
servertech/pro3x-breaker-handle, so the breaker cell can show the sheet's framed square and bar. The 3A01 keeps the first major.The controller's two Ethernet jacks, console jack, sensor jack, aux jack, USB-A and USB-B ports are modelled parts with interface keys.
Its display window and four keys are drawn.
Its plate edge has 8 notches at the stretch ends, 4 near the ring end and a lip at each side of the cord end.
Switched units declare on and off on every outlet. The Smart unit declares no outlet state.
Two census lines in existing tests move by one: the aux jack count and the USB-B interface key.
Three entries are added to the
PROUDtable oftest_built_faces_in_depth.py, for the levers that stand 18.3 proud.Each entry says the lever's across place and its 2.0 are photograph estimates.
Each device draws what its own sheet shows, beyond the 3A01:
Sources
Maturity claimed, and why
modelled. The strip, outlets, breakers and mounting positions are read from the drawings.The panel's 52.0 by 141.6 is read from the front view of the C3S sheet, which is dimensioned at 1778.0 long. Its tolerance is about 1 mm.
The places along the strip are read from that view at 600 ppi, 0.485 mm per pixel, to about 1 mm. The sheet's own raster is 300 ppi, so a source pixel is about 1 mm.
The tabs, holes, bottom-edge features, plate tabs, cover holes and housing step are read the same way.
The breaker cell is read on a 2400 ppi render at 8.252 pixels per mm, to about 1 mm.
The side view's 11 screws, dot zones, seam, end walls and nubs are read by column profile. The renders are 1800 and 2400 ppi, 6.19 and 8.25 pixels per mm.
The two renders agree to 0.1 mm, and the tolerance is about 1 mm.
The long dot band is 360 columns at 4.4964. Every dot stands within 0.9 mm of the sheet's, and five dots along it within 0.3 mm.
The side view's boxes, bars, ledges and small items are read at the same two scales. The box positions carry about 4 mm.
The ledges, their squares, uprights and rounds carry about 1.5 mm along and 1 mm below.
The side view was scanned in bands of 100 mm, and the strip under the body was scanned again at 2400 ppi, peg by peg.
The stretch before each ledge's first peg was scanned a third time.
The three scans found 162 items under, above and beside the body. 126 were already stated.
The other 36 are now in gap
side-nubs: 18 rounds, 12 end uprights and 6 uprights before each ledge's first peg.The lever places along the strip are the side view's peg centres, read at 1800 ppi to about 0.5 mm. Every lever stands within 0.3 mm of its reading.
The levers' place across and the numeral holes are scaled from a photograph by the model's 22.0 outlet pitch, a taken figure.
The outlets keep the 3A06's places across the strip, a stand-in. The cord's entry frame is a stand-in too, and differs from the sheet by 12 mm.
So the maturity is not
verified.Compared against the reference
Before and after pictures, and the maker's Detail A, are shared with the maintainer separately.
The built panel follows the maker's photograph. ETH2, AUX and SENSOR run across the top, with USB-A and USB-B below them.
Then come the display window, two keys each side, and ETH1 and CONSOLE/MODEM at the bottom.
The RESET hole and a second small hole sit beside the window's far edge, and the ring sits at the far end.
The strip was compared in 15 tiles of 120 mm at the same scale. The front features agree within about 1 mm, except the rows in the questions below.
The side screws, dot zones, seam, end walls and nubs were compared with the sheet by a column profile. Each agrees within about 1 mm.
Before, the 3A01 has a plain plate at that place. After, each device shows the panel between outlets 18 and 19.
Each outlet has a small dark lever on the side opposite its numeral and a hole by the numeral, as the photographs show.
The side faces show the dot grid in two zones with a seam, as page 5's side view does. The 3A01 draws its side as a plain rectangle and is not changed.
The rear view shows ten mounting holes, two buttons, six round end screws and the seam.
No lamp appears in any held picture of these devices, so none is drawn.
Left out
Each row is shown by a held picture and not drawn. Marks, printed text and colours are the class the maintainer has already answered.
The maintainer answered earlier: "marks, colours and the rest are a later touch".
body-colour.Rows that are shapes the kit cannot put on a face, or that belong to a shared part, are in the questions below:
side-nubs).side-nubs).side-nubs).side-nubs).housing-step).servertech/hdot-cx-outlet@1draws 30.1 across where the sheet reads 24.2 (gapoutlet-size).servertech/pro3x-cord-60309-2pe@1draws 4.5 narrower and 8.3 shorter than the sheet, and 12 mm off (gapcord-and-plug).The front view's top-edge tabs and the side view's pegs may be the same part as the levers (gap
outlet-lever). The held pages do not settle it.Each estimate has its figure, method and tolerance in a gap.
The gaps are
outlet-lever,numeral-hole,raster-detail,controller-outline,housing-step,controller-scale,side-detail,side-nubs,outlet-across-position,outlet-along-position,outlet-size,end-platesandcord-and-plug.Rows left for later parts:
Gates run locally
test_servertech_pro3x_intelligent.py: 41 passed. The new and tightened tests failed before the edit (7 failed, 34 passed).test_silent_drops.py,test_built_faces_in_depth.py,test_unplaced_majors.pyand the PRO3X module together: 78 passed.Questions for the maintainer
Merge danger
Door: two-way.
Blast radius: three new devices, one new module and a second major of the breaker part, which no existing device places. Two existing census lines move by one, and one entry is added to the table of majors kept on purpose. No existing device changes.
Main already carries the
px3-5493entry in thePROUDtable, and this change adds three more to it.The two tables keep both sides in a merge.
Anything a reviewer should look at first
PROUD.outlet-across-position).🤖 Generated with Claude Code