Add the Server Technology PRO3X Smart 3C01, Switched 3F01 and Switched POPS 3G01 - #1914

Merged
roc-ops merged 14 commits into
mainfrom
claude/servertech-pro3x-intelligent
Nov 19, 2026
Merged

roc-ops merged 14 commits into
mainfrom
claude/servertech-pro3x-intelligent

Conversation

@roc-ops

@roc-ops roc-ops commented Nov 18, 2026

Copy link
Copy Markdown
Owner

PREVIEW: needed (the three PRO3X fronts and sides, the controller panel, new devices)

Refs #1475

What this changes

Adds three 0U rack PDUs: the Server Technology PRO3X Smart 3C01, Switched 3F01 and Switched POPS 3G01.
Each is the Basic 3A01 strip with a controller panel between the two banks of outlets.
It adds one new module, servertech/pro3x-controller, seated in a bay on each device.
It also adds a second major of servertech/pro3x-breaker-handle, so the breaker cell can show the sheet's framed square and bar. The 3A01 keeps the first major.
The controller's two Ethernet jacks, console jack, sensor jack, aux jack, USB-A and USB-B ports are modelled parts with interface keys.
Its display window and four keys are drawn.
Its plate edge has 8 notches at the stretch ends, 4 near the ring end and a lip at each side of the cord end.
Switched units declare on and off on every outlet. The Smart unit declares no outlet state.
Two census lines in existing tests move by one: the aux jack count and the USB-B interface key.
Three entries are added to the PROUD table of test_built_faces_in_depth.py, for the levers that stand 18.3 proud.
Each entry says the lever's across place and its 2.0 are photograph estimates.

Each device draws what its own sheet shows, beyond the 3A01:

  • The outlets, plates and bank housings stand at the places the sheet's raster gives along the strip, to about 1 mm.
  • The 36 retention levers, one at each outlet, standing 18.3 proud. Each is centred on its peg on the side view, to about 0.5 mm.
  • A hole beside each of the 36 outlet numerals.
  • Two end lugs on each of the six banks, each 2.4 inside the bank's far edge.
  • A tab on the top edge at each outlet, with two holes, and a notch on each C13 tab.
  • A bump and a dot on the bottom edge at each outlet, and a ring at each Cx outlet.
  • Each bank's housing stepped in by 3.0 on each side where the Cx outlets change to C13.
  • A tab and two dots on each blank plate.
  • In each of the two breaker cells, a framed square and a bar with two dots.
  • Two screw holes in the front-entry cover, and a ground point drawn as a ring with a centre dot.
  • A plain plate between the controller and the far breaker.
  • The controller plate's notched outline: a wider stretch over the display and another over the jack group, four tabs in all.
  • On each side, a perforated cord-end block and a long perforated band with a seam, 11 screws and 2 nubs.
  • The 11 side screws, both dot bands, the seam and the nub caps stand where a column profile puts them, to about 1 mm.
  • The long dot band is 360 columns at a pitch of 4.4964, and every dot stands within 0.9 mm of the sheet's.
  • The rear view's ten mounting holes, two buttons, six end screws and the seam 120.7 from the cord end.

Sources

  • Server Technology data sheet C3S36RL-EPJE2MT4, page 5 (drawings, including Detail A) and pages 1 and 2 (features and ports).
  • Server Technology data sheet C3W36RL-EPJE2MT4, pages 1 and 5.
  • Server Technology data sheet C3WG36RL-EPJE2MT4, pages 1 and 5.
  • Server Technology PRO3X Rack PDU Data Sheet, pages 1 and 2: the photographs, used for the lever's place across, the numeral holes and sampled colours.
  • Nothing is copied from the maker's pages except figures and facts.

Maturity claimed, and why

modelled. The strip, outlets, breakers and mounting positions are read from the drawings.
The panel's 52.0 by 141.6 is read from the front view of the C3S sheet, which is dimensioned at 1778.0 long. Its tolerance is about 1 mm.
The places along the strip are read from that view at 600 ppi, 0.485 mm per pixel, to about 1 mm. The sheet's own raster is 300 ppi, so a source pixel is about 1 mm.
The tabs, holes, bottom-edge features, plate tabs, cover holes and housing step are read the same way.
The breaker cell is read on a 2400 ppi render at 8.252 pixels per mm, to about 1 mm.
The side view's 11 screws, dot zones, seam, end walls and nubs are read by column profile. The renders are 1800 and 2400 ppi, 6.19 and 8.25 pixels per mm.
The two renders agree to 0.1 mm, and the tolerance is about 1 mm.
The long dot band is 360 columns at 4.4964. Every dot stands within 0.9 mm of the sheet's, and five dots along it within 0.3 mm.
The side view's boxes, bars, ledges and small items are read at the same two scales. The box positions carry about 4 mm.
The ledges, their squares, uprights and rounds carry about 1.5 mm along and 1 mm below.
The side view was scanned in bands of 100 mm, and the strip under the body was scanned again at 2400 ppi, peg by peg.
The stretch before each ledge's first peg was scanned a third time.
The three scans found 162 items under, above and beside the body. 126 were already stated.
The other 36 are now in gap side-nubs: 18 rounds, 12 end uprights and 6 uprights before each ledge's first peg.
The lever places along the strip are the side view's peg centres, read at 1800 ppi to about 0.5 mm. Every lever stands within 0.3 mm of its reading.
The levers' place across and the numeral holes are scaled from a photograph by the model's 22.0 outlet pitch, a taken figure.
The outlets keep the 3A06's places across the strip, a stand-in. The cord's entry frame is a stand-in too, and differs from the sheet by 12 mm.
So the maturity is not verified.

Compared against the reference

Before and after pictures, and the maker's Detail A, are shared with the maintainer separately.
The built panel follows the maker's photograph. ETH2, AUX and SENSOR run across the top, with USB-A and USB-B below them.
Then come the display window, two keys each side, and ETH1 and CONSOLE/MODEM at the bottom.
The RESET hole and a second small hole sit beside the window's far edge, and the ring sits at the far end.
The strip was compared in 15 tiles of 120 mm at the same scale. The front features agree within about 1 mm, except the rows in the questions below.
The side screws, dot zones, seam, end walls and nubs were compared with the sheet by a column profile. Each agrees within about 1 mm.
Before, the 3A01 has a plain plate at that place. After, each device shows the panel between outlets 18 and 19.
Each outlet has a small dark lever on the side opposite its numeral and a hole by the numeral, as the photographs show.
The side faces show the dot grid in two zones with a seam, as page 5's side view does. The 3A01 draws its side as a plain rectangle and is not changed.
The rear view shows ten mounting holes, two buttons, six round end screws and the seam.
No lamp appears in any held picture of these devices, so none is drawn.

Left out

Each row is shown by a held picture and not drawn. Marks, printed text and colours are the class the maintainer has already answered.
The maintainer answered earlier: "marks, colours and the rest are a later touch".

  • Wordmark letters on the front label. The data sheet photograph and drawing show them.
  • Display contents. The photograph shows a status screen, and the sheet gives no character count.
  • Key glyphs on the four round keys. The sheet draws the keys as filled discs where the build draws rings.
  • Port names (ETH1, ETH2, CONSOLE/MODEM, USB-A, USB-B, AUX, SENSOR, RESET). Detail A and the photograph show them.
  • Symbol and rating label contents at the cord end, the legend in the breaker frame and the glyph on its bar.
  • Coloured frames round five jacks (green, blue, yellow-green, white). The photograph shows them.
  • Photograph colours. The library's dark neutral is kept on every face, as on the sibling devices. The sampled colours are recorded in the gap body-colour.

Rows that are shapes the kit cannot put on a face, or that belong to a shared part, are in the questions below:

  • The 36 lever pegs under the body on the side view (page 5), and the 2 nubs on each side. A face is the body's width (gap side-nubs).
  • The two boxes under the breakers with a thin bar under each, the flat bar under the cover and five small items under the body. They stand beyond the face too (gap side-nubs).
  • The six ledges under the banks, each with a small square and a thin upright at every peg. They stand beyond the face too (gap side-nubs).
  • The 18 ring-and-dot rounds on the first three pegs of each bank. Also 18 more thin uprights, 12 after each sixth peg and 6 before each ledge's first. They stand beyond the face too (gap side-nubs).
  • The slope of the housing's step. Decor draws a rect, circle, d-sub, slot or octagon, so the step is square (gap housing-step).
  • The Cx outlet body, which the shared part servertech/hdot-cx-outlet@1 draws 30.1 across where the sheet reads 24.2 (gap outlet-size).
  • The cord's entry frame, which the shared part servertech/pro3x-cord-60309-2pe@1 draws 4.5 narrower and 8.3 shorter than the sheet, and 12 mm off (gap cord-and-plug).

The front view's top-edge tabs and the side view's pegs may be the same part as the levers (gap outlet-lever). The held pages do not settle it.
Each estimate has its figure, method and tolerance in a gap.
The gaps are outlet-lever, numeral-hole, raster-detail, controller-outline, housing-step, controller-scale, side-detail, side-nubs, outlet-across-position, outlet-along-position, outlet-size, end-plates and cord-and-plug.

Rows left for later parts:

  • PRO2 and PRO1 units, which are separate families with separate bodies.
  • Basic CB01 and CB80, whose sheets are held but not modelled here. Basic 3A03 and 3A04 and the Metered unit have no sheet held.
  • Other -48VDC SKUs, whose output terminals have no registry key.
  • The PRO3X four-position sensor jacks and the Link RJ-12 jack, which have no key and no Link sheet.

Gates run locally

  • One whole build exited 0, after the last edit to a device file.
  • The 11,009 Python tests in the files that read the built library all passed.
  • test_servertech_pro3x_intelligent.py: 41 passed. The new and tightened tests failed before the edit (7 failed, 34 passed).
  • test_silent_drops.py, test_built_faces_in_depth.py, test_unplaced_majors.py and the PRO3X module together: 78 passed.
  • In the built SVGs of the three devices, no lever is off its peg by more than 0.3 mm of the 1800 ppi reading.
  • The same SVGs put the breakers at 31.9 and the rear seam at 120.7. All 11 screws and both seams stand at their readings.
  • Whole-library lint: no change against the baseline.
  • The device version check: 0 findings, after the three devices' records were refreshed. Versions stay.
  • The export step wrote nothing: 0 written, 0 removed, 5769 unchanged.
  • Full preflight: PASS, every check passing and no advice line. The part conformance report was run on this tree.

Questions for the maintainer

  • The 36 lever pegs under each body are not on the side faces, as a face is the body's width. Should they stay out?
  • The 2 nubs on each side are a footprint only, as a face is the body's width. Is a footprint enough?
  • The shared Cx outlet is drawn 30.1 wide, the sheet reads 24.2. A new version changes nine devices' records. May it stay until its own change?
  • The shared cord part's frame is 4.5 narrower, 8.3 shorter and 12 mm off the sheet's end view. May it stay until its own change?
  • The sheet draws each bank housing as a double line with an inner rim. The build draws one filled outline. Is that enough?
  • The breaker cell needed a second major of the shared breaker part, so the 3A01 keeps its version. Is that the right form?
  • The side view shows two breaker boxes, a bar, six bank ledges, 18 rounds under the pegs and small items under the body. Keep them out of the drawing?

Merge danger

Door: two-way.

Blast radius: three new devices, one new module and a second major of the breaker part, which no existing device places. Two existing census lines move by one, and one entry is added to the table of majors kept on purpose. No existing device changes.

Main already carries the px3-5493 entry in the PROUD table, and this change adds three more to it.
The two tables keep both sides in a merge.

Anything a reviewer should look at first

  • The controller panel is 52.0 by 141.6, read from the sheet's front view. Detail A has no scale, so its jacks are fitted to that size.
  • The outlets stand at the sheet's centres along the strip. The 3A06's places, which the sibling devices keep, are 6 to 13 mm from them.
  • Each C13 group is spaced 22.0 about its mean, because the part is 22 along. That is within 1.1 mm of the centres read.
  • The levers stand on the side view's peg centres along the strip, which are 2.2 mm nearer the cord end than the outlet centres. Their place across is read from the photograph.
  • The Switched and Switched POPS sheets show the panel small, so the shared panel is read from the C3S sheet.
  • The sheets print 81.8 for the outlet reach. The library depth stays 63.5, as on the 3A01. The levers' 18.3 is listed in PROUD.
  • The housings sit where the sheet's raster reads them, 4.9 nearer the top edge than the 3A01's (gap outlet-across-position).

🤖 Generated with Claude Code

roc-ops and others added 14 commits November 17, 2026 20:25
…d POPS 3G01

Each is the Basic 3A01 strip with a controller panel between the banks. The controller is one new module whose jacks reuse the library's parts and keys. The panel size and the outlet levers are estimated.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
The chassis note gave 81.2, the figure of the 3A06 drawing. The side view of the three data sheets prints 81.8.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…lugs, tabs and sides

Each outlet gets the hole beside its numeral, and each bank its end lugs and edge tabs. The cover gets its two screw holes and the ground point a ring with a dot. A plain plate stands before the far breaker, and the controller plate gets two tabs for its notched outline. Each side gets two perforated zones, a seam, eleven screws and two nubs. Figures are read to about 1 mm from the sheets' 300 ppi rasters and written as estimates in the gaps.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…ts second stretch and the stepped housings

The controller panel is 52.0 by 141.6, read from the sheet's front view, and its window, keys, holes and ring are placed from the same view. The plate gets its second wider stretch over the jack group and the notch at the measured depth. Each bank's housing steps in over its C13 outlets and sits where the sheet draws it. The two symbol labels move to the sheet's place. The 36 lever pegs, the nubs and the slope of the step are named in gaps, and every estimate states its tolerance. Three PROUD entries cover the levers' 18.3 reach.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…e sheet's raster and draw the tab holes, bottom-edge dots, plate tabs and controller notches

The outlets, plates, housings and lugs stand where the sheet's front view puts them along the strip, to about 1 mm. Each top tab gets two holes and each C13 tab a notch. Each outlet gets a bottom-edge bump and dot, each Cx outlet a ring, and each blank plate a tab and two dots. The controller plate gets notches at the stretch ends and near the ring end, and a lip at the cord end. The outlet-size gap says why the shared Cx part is not changed here. The PROUD entries say the lever's place and across are photograph estimates.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…e breaker handle, add the rear seam and place each lever on its peg

The sheet's breaker cell holds a framed square and a bar with two dots, so the shared breaker handle gets a second major and the first stays for the 3A01. Each lever stands on its peg's centre from the side view, to about 0.5 mm. The rear view draws its seam 119.8 mm from the cord end. The gaps state figure, method and tolerance. The table of majors kept on purpose lists the breaker handle.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…ver bar, and give every estimate its tolerance

The side gap now gives the two boxes under the breakers and the flat bar under the cover, with figures and tolerance. The controller outline's tolerance is 1 mm, as the source raster resolves. The other-side and numbering gaps and the key size state theirs.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…name the small items under the body

The side gap now gives the boxes at 175.9 to 237.6 and 1103.8 to 1165.8 from the cord end, to about 4 mm. That is the spread of three readings of the sheet's raster.
It also gives the thin bar under each box and the cover bar. Five small items under the body from 887 to 1025 mm each get a figure and a tolerance.
Depths are measured from the centre of the body's bottom line. The three devices carry the same text, and the tests read it.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…ar and split two long gap sentences

The thin bar under each box is about 12 below the body, as two readings of the raster give 11.6 and 12.6. The flat bar under the cover now has its place, 2.9 to 55.2 from the cord end.
The outlet-size and housing-step gaps each lose a sentence over 25 words, with the facts kept.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…nd uprights in the side gap

The side view draws a ledge under each of the six banks, with a small square and a thin upright at each peg.

The gap now gives each ledge's place, its depth, the method and a tolerance. The three devices carry the same note.

A whole scan of the side view in bands of 100 mm found nothing else uncovered.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…ofile and state the rounds and end uprights

Screws 5 to 11 were up to 2.4 mm off the sheet and now stand at its readings on both faces. The long dot band, the dot rows and the nub caps are re-placed to within 1 mm.

The side gaps now give the screw centres, the scale and the method. The side-nubs gap adds 18 rounds under the first three pegs of each bank and 12 more uprights after each sixth peg.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
…before each ledge and re-place small items

The long dot band is 360 columns at 4.4964, as the sheet counts it, where it was 361 at 4.48.
The cord-end block is 20 columns at 4.463.
A thin upright stands before peg 1 of each ledge. The gap states them, 42 thin uprights in all.
Screws 1 to 4, the seam and four levers move to their readings.
Every lever stands within 0.3 mm of its reading at 1800 ppi.
The tests check the tile counts, the middle dots, the seam and the six uprights.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
Signed-off-by: Jason Patterson <jpatterson@rocnetsupply.com>
roc-ops added a commit that referenced this pull request Nov 19, 2026
@roc-ops
roc-ops merged commit 04a27b2 into main Nov 19, 2026
5 checks passed
@roc-ops
roc-ops deleted the claude/servertech-pro3x-intelligent branch November 19, 2026 01:10
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

1 participant