Skip to content

Support the battery capability in smoke/co subdriver #1978

New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Closed
wants to merge 5 commits into from
Closed
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
16 changes: 16 additions & 0 deletions drivers/SmartThings/matter-sensor/profiles/co-battery.yml
Original file line number Diff line number Diff line change
@@ -0,0 +1,16 @@
name: co-battery
components:
- id: main
capabilities:
- id: carbonMonoxideDetector
version: 1
- id: battery
version: 1
- id: hardwareFault
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: SmokeDetector
18 changes: 18 additions & 0 deletions drivers/SmartThings/matter-sensor/profiles/co-comeas-battery.yml
Original file line number Diff line number Diff line change
@@ -0,0 +1,18 @@
name: co-comeas-battery
components:
- id: main
capabilities:
- id: carbonMonoxideDetector
version: 1
- id: carbonMonoxideMeasurement
version: 1
- id: battery
version: 1
- id: hardwareFault
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: SmokeDetector
19 changes: 19 additions & 0 deletions drivers/SmartThings/matter-sensor/profiles/smoke-battery.yml
Original file line number Diff line number Diff line change
@@ -0,0 +1,19 @@
name: smoke-battery
components:
- id: main
capabilities:
- id: smokeDetector
version: 1
- id: battery
version: 1
- id: hardwareFault
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: SmokeDetector
preferences:
- preferenceId: certifiedpreferences.smokeSensorSensitivity
explicit: true
21 changes: 21 additions & 0 deletions drivers/SmartThings/matter-sensor/profiles/smoke-co-battery.yml
Original file line number Diff line number Diff line change
@@ -0,0 +1,21 @@
name: smoke-co-battery
components:
- id: main
capabilities:
- id: smokeDetector
version: 1
- id: carbonMonoxideDetector
version: 1
- id: battery
version: 1
- id: hardwareFault
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: SmokeDetector
preferences:
- preferenceId: certifiedpreferences.smokeSensorSensitivity
explicit: true
Original file line number Diff line number Diff line change
@@ -0,0 +1,23 @@
name: smoke-co-comeas-battery
components:
- id: main
capabilities:
- id: smokeDetector
version: 1
- id: carbonMonoxideDetector
version: 1
- id: carbonMonoxideMeasurement
version: 1
- id: battery
version: 1
- id: hardwareFault
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: SmokeDetector
preferences:
- preferenceId: certifiedpreferences.smokeSensorSensitivity
explicit: true
Original file line number Diff line number Diff line change
@@ -0,0 +1,31 @@
name: smoke-co-temp-humidity-comeas-battery
components:
- id: main
capabilities:
- id: smokeDetector
version: 1
- id: carbonMonoxideDetector
version: 1
- id: relativeHumidityMeasurement
version: 1
- id: temperatureMeasurement
version: 1
- id: carbonMonoxideMeasurement
version: 1
- id: battery
version: 1
- id: hardwareFault
version: 1
- id: firmwareUpdate
version: 1
- id: refresh
version: 1
categories:
- name: SmokeDetector
preferences:
- preferenceId: certifiedpreferences.smokeSensorSensitivity
explicit: true
- preferenceId: tempOffset
explicit: true
- preferenceId: humidityOffset
explicit: true
45 changes: 41 additions & 4 deletions drivers/SmartThings/matter-sensor/src/smoke-co-alarm/init.lua
Original file line number Diff line number Diff line change
Expand Up @@ -20,6 +20,13 @@ local CARBON_MONOXIDE_MEASUREMENT_UNIT = "CarbonMonoxideConcentrationMeasurement
local SMOKE_CO_ALARM_DEVICE_TYPE_ID = 0x0076
local PROFILE_MATCHED = "__profile_matched"

local HUE_MANUFACTURER_ID = 0x100B

local battery_support = {
NO_BATTERY = "NO_BATTERY",
BATTERY_PERCENTAGE = "BATTERY_PERCENTAGE"
}

local version = require "version"
if version.api < 10 then
clusters.SmokeCoAlarm = require "SmokeCoAlarm"
Expand Down Expand Up @@ -49,13 +56,18 @@ end
local supported_profiles =
{
"co",
"co-battery",
"co-comeas",
"co-comeas-battery",
"smoke",
"smoke-battery",
"smoke-co-comeas",
"smoke-co-temp-humidity-comeas"
"smoke-co-comeas-battery",
"smoke-co-temp-humidity-comeas",
"smoke-co-temp-humidity-comeas-battery"
}

local function match_profile(device)
local function match_profile(device, battery_supported)
local smoke_eps = embedded_cluster_utils.get_endpoints(device, clusters.SmokeCoAlarm.ID, {feature_bitmap = clusters.SmokeCoAlarm.types.Feature.SMOKE_ALARM})
local co_eps = embedded_cluster_utils.get_endpoints(device, clusters.SmokeCoAlarm.ID, {feature_bitmap = clusters.SmokeCoAlarm.types.Feature.CO_ALARM})
local temp_eps = embedded_cluster_utils.get_endpoints(device, clusters.TemperatureMeasurement.ID)
Expand Down Expand Up @@ -84,6 +96,9 @@ local function match_profile(device)
if #co_level_eps > 0 then
profile_name = profile_name .. "-colevel"
end
if battery_supported == battery_support.BATTERY_PERCENTAGE then
profile_name = profile_name .. "-battery"
end

-- remove leading "-"
profile_name = string.sub(profile_name, 2)
Expand All @@ -108,7 +123,13 @@ end

local function device_init(driver, device)
if not device:get_field(PROFILE_MATCHED) then
match_profile(device)
local battery_feature_eps = device:get_endpoints(clusters.PowerSource.ID, {feature_bitmap = clusters.PowerSource.types.PowerSourceFeature.BATTERY})
-- Hue devices support the PowerSource cluster but don't support reporting battery percentage remaining
if #battery_feature_eps > 0 and device.manufacturer_info.vendor_id ~= HUE_MANUFACTURER_ID then
device:send(clusters.PowerSource.attributes.AttributeList:read())
else
match_profile(device, battery_support.NO_BATTERY)
end
end
device:subscribe()
end
Expand Down Expand Up @@ -201,6 +222,16 @@ local function battery_alert_attr_handler(driver, device, ib, response)
end
end

local function power_source_attribute_list_handler(driver, device, ib, response)
for _, attr in ipairs(ib.data.elements) do
-- Re-profile the device if BatPercentRemaining is available
if attr.value == clusters.PowerSource.attributes.BatPercentRemaining.ID then
match_profile(device, battery_support.BATTERY_PERCENTAGE)
return
end
end
end

local matter_smoke_co_alarm_handler = {
NAME = "matter-smoke-co-alarm",
lifecycle_handlers = {
Expand All @@ -219,7 +250,10 @@ local matter_smoke_co_alarm_handler = {
[clusters.CarbonMonoxideConcentrationMeasurement.ID] = {
[clusters.CarbonMonoxideConcentrationMeasurement.attributes.MeasuredValue.ID] = carbon_monoxide_attr_handler,
[clusters.CarbonMonoxideConcentrationMeasurement.attributes.MeasurementUnit.ID] = carbon_monoxide_unit_attr_handler,
}
},
[clusters.PowerSource.ID] = {
[clusters.PowerSource.attributes.AttributeList.ID] = power_source_attribute_list_handler,
},
},
},
subscribed_attributes = {
Expand All @@ -246,6 +280,9 @@ local matter_smoke_co_alarm_handler = {
},
[capabilities.batteryLevel.ID] = {
clusters.SmokeCoAlarm.attributes.BatteryAlert,
},
[capabilities.battery.ID] = {
clusters.PowerSource.attributes.BatPercentRemaining,
}
},
can_handle = is_matter_smoke_co_alarm
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -73,6 +73,8 @@ local cluster_subscribe_list = {
}

local function test_init()
local read_attribute_list = clusters.PowerSource.attributes.AttributeList:read()
test.socket.matter:__expect_send({mock_device.id, read_attribute_list})
local subscribe_request = cluster_subscribe_list[1]:subscribe(mock_device)
for i, cluster in ipairs(cluster_subscribe_list) do
if i > 1 then
Expand All @@ -81,7 +83,6 @@ local function test_init()
end
test.socket.matter:__expect_send({mock_device.id, subscribe_request})
test.mock_device.add_test_device(mock_device)
mock_device:expect_metadata_update({ profile = "smoke-co-temp-humidity-comeas" })
end

test.set_test_init_function(test_init)
Expand Down
Original file line number Diff line number Diff line change
@@ -0,0 +1,131 @@
-- Copyright 2024 SmartThings
--
-- Licensed under the Apache License, Version 2.0 (the "License");
-- you may not use this file except in compliance with the License.
-- You may obtain a copy of the License at
--
-- http://www.apache.org/licenses/LICENSE-2.0
--
-- Unless required by applicable law or agreed to in writing, software
-- distributed under the License is distributed on an "AS IS" BASIS,
-- WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
-- See the License for the specific language governing permissions and
-- limitations under the License.

local test = require "integration_test"
local capabilities = require "st.capabilities"
local t_utils = require "integration_test.utils"
local uint32 = require "st.matter.data_types.Uint32"

local clusters = require "st.matter.clusters"
clusters.SmokeCoAlarm = require "SmokeCoAlarm"
local version = require "version"
if version.api < 10 then
clusters.SmokeCoAlarm = require "SmokeCoAlarm"
clusters.CarbonMonoxideConcentrationMeasurement = require "CarbonMonoxideConcentrationMeasurement"
end

local mock_device = test.mock_device.build_test_matter_device({
profile = t_utils.get_profile_definition("smoke-co-temp-humidity-comeas-battery.yml"),
manufacturer_info = {
vendor_id = 0x0000,
product_id = 0x0000,
},
endpoints = {
{
endpoint_id = 0,
clusters = {
{cluster_id = clusters.Basic.ID, cluster_type = "SERVER"},
},
device_types = {
{device_type_id = 0x0016, device_type_revision = 1} -- RootNode
}
},
{
endpoint_id = 1,
clusters = {
{cluster_id = clusters.SmokeCoAlarm.ID, cluster_type = "SERVER", feature_map = clusters.SmokeCoAlarm.types.Feature.CO_ALARM | clusters.SmokeCoAlarm.types.Feature.SMOKE_ALARM},
{cluster_id = clusters.TemperatureMeasurement.ID, cluster_type = "SERVER"},
{cluster_id = clusters.RelativeHumidityMeasurement.ID, cluster_type = "SERVER"},
{cluster_id = clusters.CarbonMonoxideConcentrationMeasurement.ID, cluster_type = "SERVER", feature_map = clusters.CarbonMonoxideConcentrationMeasurement.types.Feature.NUMERIC_MEASUREMENT},
{cluster_id = clusters.PowerSource.ID, cluster_type = "SERVER", feature_map = clusters.PowerSource.types.PowerSourceFeature.BATTERY},
},
device_types = {
{device_type_id = 0x0076, device_type_revision = 1} -- Smoke CO Alarm
}
}
}
})

local cluster_subscribe_list = {
clusters.SmokeCoAlarm.attributes.SmokeState,
clusters.SmokeCoAlarm.attributes.TestInProgress,
clusters.SmokeCoAlarm.attributes.COState,
clusters.SmokeCoAlarm.attributes.HardwareFaultAlert,
clusters.TemperatureMeasurement.attributes.MeasuredValue,
clusters.TemperatureMeasurement.attributes.MinMeasuredValue,
clusters.TemperatureMeasurement.attributes.MaxMeasuredValue,
clusters.RelativeHumidityMeasurement.attributes.MeasuredValue,
clusters.CarbonMonoxideConcentrationMeasurement.attributes.MeasuredValue,
clusters.CarbonMonoxideConcentrationMeasurement.attributes.MeasurementUnit,
clusters.PowerSource.attributes.BatPercentRemaining,
}

local function test_init()
local read_attribute_list = clusters.PowerSource.attributes.AttributeList:read()
test.socket.matter:__expect_send({mock_device.id, read_attribute_list})
local subscribe_request = cluster_subscribe_list[1]:subscribe(mock_device)
for i, cluster in ipairs(cluster_subscribe_list) do
if i > 1 then
subscribe_request:merge(cluster:subscribe(mock_device))
end
end
test.socket.matter:__expect_send({mock_device.id, subscribe_request})
test.mock_device.add_test_device(mock_device)
end

test.set_test_init_function(test_init)

test.register_coroutine_test(
"Test profile change when battery percent remaining attribute (attribute ID 12) is available",
function()
test.socket.matter:__queue_receive(
{
mock_device.id,
clusters.PowerSource.attributes.AttributeList:build_test_report_data(mock_device, 1, {uint32(12)})
}
)
mock_device:expect_metadata_update({ profile = "smoke-co-temp-humidity-comeas-battery" })
end
)

test.register_coroutine_test(
"Test that profile does not change when battery percent remaining attribute is not available",
function()
test.socket.matter:__queue_receive(
{
mock_device.id,
clusters.PowerSource.attributes.AttributeList:build_test_report_data(mock_device, 1, {uint32(0)})
}
)
end
)

test.register_coroutine_test(
"Battery percent reports should generate correct messages",
function()
test.socket.matter:__queue_receive(
{
mock_device.id,
clusters.PowerSource.attributes.BatPercentRemaining:build_test_report_data(mock_device, 1, 150)
}
)
test.socket.capability:__expect_send(
mock_device:generate_test_message(
"main", capabilities.battery.battery(math.floor(150 / 2.0 + 0.5))
)
)
end
)

test.run_registered_tests()
Loading